Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S05-086
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/01/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/13/2005 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Passed | DATE: September 13, 2005 TO: Patricia Gehlen; CDRC Coordinator SUBJECT: Moonrise at Starr Pass Condos 2nd resubmittal Final Plat Engineering Review REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: S05-086 SUMMARY: The revised Final Plat, response letter, and other documentation were received by Development Services Department Engineering Division on September 1, 2005. Engineering Division has reviewed the received items and does not recommend approval of the Final Plat at this time. FINAL PLAT COMMENTS: 1) City of Tucson Development Standards (DS) Section No. 2-03.6.4.E: Provide surveyable building setback from the ERZ 100-yr floodplain. This line will need either labeled offsets or bearings and distances. 2) DS Sec.2-03.6.4.A: In response letter, state whether the sewer is private, public, or both. 3) DS Sec.2-03.6.6: Submit Covenants, Conditions, and Restrictions (CC&R's) establishing responsibility for construction, maintenance, and ownership of any proposed common areas, open space, private streets, or similar joint use. A final signed original copy of the CC&R's will eventually be needed for approval of the Final Plat. Assure that the CC&R's provide for: a) establishing responsibility for construction, maintenance, and ownership of these proposed commonly-owned areas; b) maintenance of, and liability for any channels, and drainage structures including the spillways; c) maintenance of and liability for any other proposed commonly-owned areas; d) Assure that the drainage maintenance and responsibility verbiage from DS Sec.10-02.14.3.2.a-d & 10-02.14.3.3 is added to the CC&R's, per Standards Manual for Drainage Design and Floodplain Management section 14.3.2, and as provided in Drainage Report. e) In response letter include page number in the CC&R's where the drainage liability and maintenance verbiage is found. f) Include any Drainage Report Maintenance checklist to the CC&R's. g) includes the various conditions of any rezoning or other special situations requiring permanent administration by an owners' association. 4) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until one of the following has been provided: a) if there is any remaining construction, the financial assurances are submitted and approvable; or, b) provide a copy of Certificate of Occupancy paperwork accepted by the City of Tucson for the final construction. 5) DS Sec.2-03.7.1.B: Provide signature and seal of both the Surveyor and Civil Engineers for the project. When engineering information (floodplain, setbacks) is provided on the final plat, the seal and signature of the responsible engineer is also required. This will be required for approval of the Final Plat for this condo conversion. The next submittal should address all the above items. Submit revised Final Plat, CC&R's, documentation regarding completion or assurance for the project, and a response letter. Final Plat may be re-submitted in mylar format. To schedule a meeting or if you have any questions, you may call me at 791-5550 extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services Department |
| 09/18/2005 | ELIZABETH EBERBACH | ENGINEERING | Pre-mylar submittal at counter | Approv-Cond | DATE: September 16, 2005 TO: Patricia Gehlen; CDRC Coordinator SUBJECT: Moonrise at Starr Pass Condos 3rd resubmittal Final Plat Engineering Review REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: S05-086 SUMMARY: The revised Final Plat and CC&R documentation, and copies of the Certificate of Occupancy sheets were reviewed at the counter with Warren Thompson of Stantec on September 16, 2005. All documents were acceptable to DSD Engineering Division with the following condition of approval: FINAL PLAT CONDITION OF APPROVAL: 1) City of Tucson Development Standards (DS) Section No 2-03.7.1.B: On sheet 1, only the floodplain line is shown to be certified by the engineer, however the building setback from the ERZ 100-yr floodplain had been added as a delineation. For the engineer's certification, either revise verbiage to include all engineering information, or add the floodplain building setback to the certification. This may be shown on the mylar submittal. If you have any questions, you may call me at 791-5550 extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services Department |
| 09/22/2005 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | The above mentioned project was conditionally approved on August 9, 2005 and does not need to be submitted to Pima County Development Review Division for any further reviews. If you have any further questions, please do not hesitate to contact me. Sincerely, Dickie Fernández, E.I.T. Pima County Development Services Department 201 N Stone Avenue, 2nd Floor Tucson, AZ 85701 Telephone: (520) 740-6947 Fax: (520) 740-6380 |
| 09/27/2005 | ELIZABETH EBERBACH | ENGINEERING | mylar submittal | Approved | Engineering has approved the mylar submittal. -EE |
| 09/28/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | `COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES September 28, 2005 David Seese Stantec Consulting 201 North Bonita Avenue, Suite 101 Tucson, AZ 85745 Subject: S05-086 Moonrise at Starr Pass Condominium Final Plat Dear David: The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make the any necessary corrections and submit the following documents: (2) Title reports current within the last (30) days. (1) Executed Final Plat Double Matte Océ or Photo Mylar. (1) * Check made to "Reproductions, Inc." in the amount of $8.50 per plat page for Mayor & Council distribution. (1) * Check made to "Reproductions, Inc." in the amount of $55.00 per plat page for recorded plat distribution. (1) Check made to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CCR fees are $9.00 for the first 5 pages and $1.00 for each additional page. (1) Executed and notarized CC&Rs (if applicable). *Please do not combine the checks for "Reproductions, Inc.". They are processed at different times and require separate checks. An account number is also acceptable. Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CCR's and assurances must be approved at the same Mayor and Council Meeting. Please expect 3 -4 weeks from the date submitted to the date scheduled for Mayor and Council approval. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 750-7470 |