Plan Number: S05-061
Parcel: Unknown

Address:
4275 N STONE AV

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S05-061
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/04/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/17/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approved August 16, 2006

To: René A. G. Piña, P.E

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael J.Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Stone Lane Townhomes a Condominium
Units 1 thru 14 and Common Areas "A" & "B"
and Limited Common Areas 1A through 14B
Final Plat - 1st Submittal
S05-061

The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
08/24/2006 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S05-061
Stone Lane Townhomes
Final Plat Resubmittal

TRANSMITTAL DATE: August 4, 2006

DUE DATE: September 1, 2006

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Building elevations were not found on sheet 2 of 2. Since the same unit is to be constructed 14 times one fully dimensioned building elevation and cross section typical for the development must be added.



If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550.

KAA C:\planning\cdrc\finalplat\S05-061fpr.doc


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
09/01/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-061 STONE LANE TOWNHOMES/REVISED FINAL PLAT
DATE: September 1, 2006



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.





***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County's
Geographic Information System. Your support is greatly appreciated.***










jg
09/04/2006 JOSE ORTIZ ENGINEERING REVIEW Approv-Cond To avoid confusion in regards to the boundaries of the detention basin please hatch the detention basin boundaries with a light-hatching pattern.

To complete the review of the final plat a revised Assurance Package is required to cross-reference the Assurances against the final plat.

If you have any questions, I can be reached at 791-4259 x305 or Jose.Ortiz@tucsonaz.gov.
09/11/2006 FRODRIG2 COT NON-DSD REAL ESTATE Denied S05-061 Stone lane Townhomes: Resubmittal - CDRC - Final Plat Review - Request a dashed line along the N. boundary to identify the "1' No Access Easement." Also, keynote 1. states "1' No Access Easement granted to Pia County by this Plat" should be changed to read "1' no access easement granted by this Plat."
09/18/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 18, 2006

Rene Pina
2030 East Broadway
Tucson, AZ 85719

Subject: S05-061 Stone Lane Townhomes Final Plat

Dear Rene

Your submittal of August 4, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Final Plat (Real Estate, Zoning, DSD)







Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 514-6893