Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S05-061
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/08/2006 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: Oro Valley Planning Department (Fax-742-1022) Attn: Shirley Gay 11000 N. La Canada Dr. Tucson, Az 85737-7015 FROM: Gary Ault Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: December 9, 2005 RE: Assessor’s Review and Comments Regarding Final Plat S05-061 Stone Lane Townhomes T131324 (105-12) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Jessica Shettleroe |
| 02/09/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES February 9, 2006 Rene Pina 2030 East Broadway Tucson, AZ 85719 Subject: S05-061 Stone Lane Townhomes Final Plat Dear Rene Your submittal of November 8, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 6 Copies Revised Final Plat (Wastewater, Addressing, Real Estate, Zoning, Engineering, DSD) 2 Copies Revised CC&R's (Engineering, DSD) 2 Copies Title Report (Real Estate, DSD) Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 514-6893 |
| 11/08/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 11/30/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-061 STONE LANE TOWNHOMES / FINAL PLAT DATE: NOVEMBER 29, 2005 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1: Label Stone Court on pg. 2. 2: Delete site address on pg. 1. |
| 11/30/2005 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | December 27, 2005 To: René A. G. Piña, P.E. Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department ____________________________________ From: Michael Harrington (520-740-6579), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: Stone Lane Townhomes a Condominiums Units 1-14 and CAs A & B and LCAs 1A-14B Final Plat - 1st Submittal S05-061 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. 1. The tentative plat for this project has not yet been approved. Please be aware that the final plat cannot be approved until after the tentative plat has been approved. 2. Sheet 1: Revise the Dedication block, 2nd paragraph, 3rd sentence, so that: PRIVATE SEWERS are included in the list of responsibilities of the ASSOCIATION OF INDIVIDUAL LOT OWNERS. 3. Sheet 1: Add a General Note that states: All LANDSCAPING WITHIN 10' OF ANY PUBLIC SEWER MAIN IN THE STONE AVENUE RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4. 4. We will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the . The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter CC: Project File |
| 12/06/2005 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: STONE LANE TOWNHOMES S05-061 Tucson Electric Power Company has reviewed and approved the final plat submitted November 8, 2005. In order to apply for electric service, call the New Construction Department at (520) 770-2062. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Warren McElyea Design/Build - DB 102 Tucson Electric Power Company P. O. Box 711 Tucson, AZ 85702 Please call me at (520) 917-8745, should you have any questions. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |
| 12/08/2005 | DAVID RIVERA | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: S05-061 Stone Lane Condominiums, Units 1-14 and Common area "A" and "B", and Common Elements 1A - 14B Final Plat TRANSMITTAL DATE: December 8, 2005 DUE DATE: December 8, 2005 COMMENTS: 1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before December 7, 2006. As of this final plat review date the tentative plat has not been approved therefore the one year date of the final plat approval is based on the date of submittal of the final plat documents. Once the tentative plat has been approved the approval date of the final plat will be on one year from the tentative plat approval date. This date will be provided on a future review of the final plat. 2. All text height must be a minimum 12 point (.12). Adjust the text height in the location map to meet this standard. DS 2-03.6.1.C 3. General note 2 related to the existing zoning is not required to be listed on the final plat. Please remove and replace the note with the following note. "The number of condominium units proposed is 14." DS 2-03.6.2.B 4. Revise general notes number four to state the following. "There will be no further subdivision of land or units without the expressed approval of the City of Tucson." DS 2-03.6.2.H 5. Please review and revise the fourth paragraph under the dedication text block. The paragraph should be written verbatim. DS 2-03.6.3.B.3 6. Please review and revise the "Approval" and "Recordation Data" text block as listed in development standards 2-03.6.3.D. 7. The following items must be added to the plan. The building elevations and cross sections fully dimensioned. The Unit Area Table must include the volume areas for each unit. The floor plans of the units if all different must be added to the plan. If the same unit is to be constructed 14 times one elevation and cross section typical for the development must be added and fully dimensioned as requested. 8. This final plat cannot be approved until the CDRC committee has approved the tentative plat. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. DGR C:\planning\cdrc\finalplat\S05061fp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: final plat, and additional requested information or documents |
| 12/12/2005 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | DATE: December 12, 2005 TO: Patricia Gehlen, CDRC Manager FROM: Jose E. Ortiz, Civil Engineering SUBJECT: Engineering review of the Stone Lane Townhomes Final Plat. The activity number is S05-061. RESUBMITTAL REQUIRED: Final Plat, CC&R, Assurances Engineering has reviewed the received items and does not recommend approval of the Final Plat. Please address the following review comments prior to the next submittal. FINAL PLAT 1. 6.2 General Notes. The following general notes will appear on the final plat. Additional notes specific to each project are required where pertinent. Complete the blanks where the information is available. DS 2-03.6.2 q "The total number of lots is ____." DS 2-03.6.2.B 2. Assurances. DS 2-03.6.3.E The following ASSURANCE block must be placed on the plat's first sheet. q ASSURANCES "This is to certify that all improvements, such as streets, sidewalks, sewers, water and utility installation, drainage and flood control facilities, and monuments, required by the City of Tucson have been completed or the future completion of such improvements has been assured by the posting of performance bonds, assurances, or other security as the City of Tucson deems necessary and proper." _______________________________________________ q City of Tucson Development Services Department Director _______________________________________________ q City of Tucson Engineer 3. Show detention/retention areas in a surveyable and readily retraceable manner. DS 2-03.6.4.I 4. Separate the Detention Basin common areas from all other common areas. This will isolate the location of the detention basin and assist in clarifying the maintenance responsibility boundaries to the owner. 5. Show Bearing and distance along centerline of the Private Road running east and west. 6. A one-half (½) inch iron rod tagged by a registered land surveyor will be set at all corners upon completion of construction. DS 2-03.6.5.C.4.b CC&R's The Covenants, Conditions, and Restrictions (CC&Rs), Final Plats, or Development Plans shall have a note stating (a) that the owner or owners shall be solely responsible for operation, maintenance, and liability for drainage structures and detention basins; (b) that the owner or owners shall have an Arizona Registered Professional Civil Engineer prepare a certified inspection report for the drainage and detention/retention facilities at least once each year, and that these regular inspection reports will be on file with the owner for review by City staff, upon written request; (c) that City staff may periodically inspect the drainage and detention/retention facilities to verify that scheduled and unscheduled maintenance activities are being performed adequately; and (d) that the owner or owners agree to reimburse the City for any and all costs associated with maintaining the drainage and detention/retention facilities, should the City find the owner or owners deficient in their obligation to adequately operate and maintain their facilities. SMDDFM 14.3.4.2 ASSURANCE PACKAGE Amendment to Trust: 1. Modify the common area descriptions of the subdivision against the Title Block on the Final Plat due to the above comments. 2. Amendment to Trust original seal(s) 3. An Exhibit "legal description" is typically attached. Agreement To Construct 1. Modify the common area descriptions of the subdivision against the Title Block on the Final Plat due to the above comments. 2. Agreement to Construct original notary seal(s) and signatures 3. Assurable items shall include improvements for: Sewer (public or private?) and Water. Please provide the following with the assurance package: Title Reports: current information regarding easements (with types and docket & page) as well as boundary survey data (that should match the plat). DS Sec.2-03.6.3.B.4: The title report should be current within 30 days of recordation of the proposed plat. Special Warranty Deed Location Map If you have any questions, I can be reached at 791-5640 ext. 1191 or jose.ortiz@tucsonaz.gov Jose E. Ortiz, PE Civil Engineer |
| 12/13/2005 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Denied | S05-061; Stone Lane, No Comment except that there was no title report to review and the arrow pointing to the one foot no access easement between lot 7 and Stone is missing the #1 reference. |