Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S05-056
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/05/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 04/22/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-056 JACARANDA VILLAGE CASITAS/FINAL PLAT DATE: 4/20/05 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Change Rosewood Avenue to Street on Location Map. 2.) Spell out all street suffixes on pg. 2. |
| 04/27/2005 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Ed Abrigo, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: April 27, 2005 RE: Assessor’s Review and Comments Regarding Final Plat S05-056 Jacaranda Village Casitas T141510 (133-32) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Susan King |
| 04/29/2005 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | April 28, 2005 TO: Wocky Redsar Castro Engineering Corp. THRU: Craig Gross City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Jacaranda Village Casitas, Units 1-32 and Common Areas A-C Final Plat – 1st Submittal S05-056 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. A telephone call was placed to you on April 27, 2005 to explain the potential consequences of connecting to an existing public sewer line of this nature. This project proposes connecting to an existing public sewer line 15 inches in diameter or larger which conveys high volumes of wastewater, and thus the owner, engineer and contractor shall be aware that a flow management plan may be required. A private Sewer Service Agreement for the proposed number of residential units has been sent to your office. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals should be returned to Pima County Wastewater Management in order to satisfy the necessary requirements needed to approve the final plat. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 05/02/2005 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approved | Laith Alshami, Engineering and Floodplain Review, 05/02/2005 SUBJECT: Jacaranda Village Casitas S05-056, T14S, R15E, SECTION 10 RECEIVED: Final Plat and CC & R's on April 06, 2005 The subject project has been reviewed. The Final Plat is recommended for approval pertaining to Engineering and Floodplain subject to the following: 1. Provide the full S(YR)-________ subdivision case number on the Final Plat Mylar as required by D.S. 2-03.6.1.K. 2. This Office recommends including the Drainage Facilities maintenance checklist in the CC & R's, as an exhibit, to allow the Home Owners Association access to it and facilitate their maintenance responsibilities. 3. Submit the Original Assurances with the Final Plat Mylar RESUBMITTAL REQUIRED: Final Plat Mylar and Assurances |
| 05/05/2005 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approv-Cond | Subject: Jacaranda Village Casitas, S05-056 Tucson Electric Power (TEP) has reviewed the final plat for the subject project and conditionally approves the plat. Please add a 10' wide TEP easement at the transformers and for the underground cable as shown on the construction drawing. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 05/09/2005 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS 1. An applicant has one (1) year from the date of approval of tentative plat/development plan to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before August 11, 2005. 2. A copy of the stamped approved development plan (D03-007) must be submitted along with the final plat. Additional comments may be forthcoming upon submittal of the approved development plan. 3. Reference recorded subdivision plats by book and page numbers in the location map. (D.S. 2-03.6.1.D.2) 4. This plat has been assigned subdivision case number S05-056. Note the subdivision case number in the lower right corner of each sheet on all plans. (D.S. 2-03.6.1.K) 5. Is this subdivision intended as a condominium project? If so, provide the following: a) fully dimensioned cross section for each building model or if the same model is to be used provide a typical; b) cubic air space matrix/schedule; c) dimensioned elevations and floor plans. If the subdivision is a condominium, a statement to that effect shall be included in the title block. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. |
| 05/11/2005 | CRAIG GROSS | COT NON-DSD | REAL ESTATE | Approved | no objections. |
| 05/11/2005 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed |