Plan Number: S05-052
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S05-052
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/07/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond July 5, 2006

To: Kent A. Delph, P.E., Delph Engineering, Inc.

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael J. Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Barrio Pantano
Lots 1-57 and Common Areas "A"-"D"
Final Plat - 2nd Submittal
S05-052

The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



The Sewer Service Agreement has been forwarded to PCWMD for further processing.

Sheet 1: General Notes #6 and #12 are the same.

Sheet1: Revise the Beneficiary block so that:

The title company name appears as it does in the Dedication block.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
07/15/2006 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera
Principal Planner

PROJECT:
Barrio Pantano
S05-052
Final Plat

TRANSMITTAL: July 15, 2006
DUE DATE: July 25, 2006

1. As acknowledged in the respsonse comments tentative plat approval is required prior to final plat approval.

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
07/19/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-052 BARRIO PANTANO/FINAL PLAT
DATE: 7/18/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***




ES
07/21/2006 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: BARRIO PANTANO

Lots 1-57

S05-052



Tucson Electric Power Company (TEP) has received the final plat
submitted for review June 26, 2006. TEP is unable to approve the plat
at this time.



An electrical design to determine our easement requirements will be
provided on the Approved Tentative Plat within fifteen (15) working days
upon receipt of the plat. Additional plans necessary for preparation of
the design are: building plans including water, electrical, landscape,
sidewalk and paving plans. Also, submit the AutoCAD version of the plat
on a CD or email to lcastillo@tep.com <mailto:lcastillo@tep.com> .
Should you have any questions, please contact me at (520) 917-8745.


Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com
07/25/2006 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 07/25/2006,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Barrio Pantano
S05-052, T14S, R15E, SECTION 219

RECEIVED: Final Plat and Assurances on June 26, 2006

Final Plat:

The subject submittal has been reviewed. The Final Plat can not be approved at this time. Address the following comments on a revised Final Plat:

1. Show a 1' no access easement on the side of lots 44, 45, 1 (adjacent to Common Area "D") and 7 (adjacent to Common Area "B") (D.S. 2-03.6.4.H).
2. Although the basis of bearing is shown on the Plat, it does not appear that the subject development is tied into the basis of bearing. Verify compliance with the requirements of D.S. 2-03.6.5.A.
3. Revise the words (City of Tucson Engineer) in the Assurances Block to (City of Tucson Development Services Department Engineering Administrator).
4. It does not appear that this project is dedicating any new public right of way, parks, drainageways, or new easements that necessitate paragraphs 2 and 3 in the Dedication. Address this issue and revise as necessary.

Assurances:

The Assurances Package is missing the following information:

1. The "Agreement to construct Subdivision Improvements" is missing Exhibit "A" to Exhibit "A".
2. Exhibit "B" to Exhibit "A" is missing the following assurable item:
· "If any offsets against impact fees have been requested, all improvements that are the subject of the requested offsets shall be completed and accepted by the city prior to the final release of assurances. Assurances may be partially released prior to the completion of all improvements provided the releases are proportional to the level of completion of improvements".
3. The "Amendment to Trust" is missing Exhibit "A".

CC & R's:

1. Revise Article Ten in the CC & R's to replace "Pima County" with "City of Tucson".
2. This Office recommends attaching the Drainage Facilities Maintenance Checklist to the CC & R's as an exhibit to facilitate the maintenance process for the Association.


RESUBMITTAL REQUIRED: Revised Final Plat, Assurances and CC & R's
07/25/2006 LAITH ALSHAMI ENGINEERING REVIEW Denied .
07/26/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 26, 2006

Kent Delph
Delph Engineering
221 North Court #103
Tucson, AZ 85701

Subject: S05-052 Barrio Pantano Final Plat

Dear Kent:

Your submittal of June 26, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Final Plat (TEP, Engineering, DSD)






Should you have any questions, please call me at 791-5608, ext 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 882-6570