Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S05-052
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S05-052
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/06/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
06/06/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the landscape plan to note the depths and include slope ratios for retention and detention basins. Basins are required to have slopes no steeper than 4:1 where depths exceed three feet; 3:1 for unprotected slopes and 2:1 for protected slopes for depths less than three feet. DS 10-01.4

2) Revise the tentaive plat and accompanying details to comply with comment 1.

RESUBMITTAL OF ALL PLANS IS REQUIRED.
06/22/2006 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera
Principal Planner

PROJECT:
S05-052
Barrio Pantano
Tentative Plat

TRANSMITTAL: June 22, 2006
DUE DATE: July 5, 2006

1. Revise the perimeter yard setback in the calculations note 6 to be based on "height of exterior building wall". The perimeter yard indicator for RCP-9 is "CC", which, with adjacent C-1 zoning, requires a perimeter yard setback based on the height of the exterior building wall rather than 3/4 of the height.
D.S. 2-10.3.1.B,
LUC 3.2.6.4

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
06/24/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

June 24, 2006

Kent Delph
Delph Engineering
221 North Court #103
Tucson, AZ 85701

Subject: S05-052 Barrio Pantano Tentative Plat

Dear Kent:

Your submittal of June 6, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Tentative Plat (Landscape, Zoning, DSD)






Should you have any questions, please call me at 791-5608, ext 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 882-6570