Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S05-048
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S05-048
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/18/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
10/19/2005 JOE LINVILLE LANDSCAPE REVIEW Approved
10/19/2005 JIM EGAN COT NON-DSD FIRE Approved The Tentative Plat is approved October 19, 2005.
10/24/2005 JCLARK3 ENV SVCS REVIEW Approved * Turnaround placed on south end of the property.
* Approved for APC curbside service. APC's are to be placed and removed from the collection area on the day of service.
10/25/2005 JOSE ORTIZ ENGINEERING REVIEW Approved
10/27/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S05-048 Stone Crossing Condominiums 10/27/05

(XXXX) Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-84-51 – Conditions Not Met
C9-89-26 – Conditions Not Met
C9-80-68 - Annexation

NEIGHBORHOOD PLAN: North Stone

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 11/1/05

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
(XXXX) RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on: 7/26/05
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: DCE 791-4505 DATE: 10/25/05DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S05-048 Stone Crossing Condominiums 09/23/05

(XXXX) Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-84-51 – Conditions Not Met
C9-89-26 – Conditions Not Met
C9-80-68 - Annexation

NEIGHBORHOOD PLAN: North Stone

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 9/22/05

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
(XXXX) No Additional Comments - Complies With Planning Comments Submitted on: 7/26/05
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: DCE 791-4505 DATE: 7/25/05DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S05-048 Stone Crossing Condominiums

(XXXX) Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-84-51 – Conditions Not Met
C9-89-26 – Conditions Not Met
C9-80-68 - Annexation

NEIGHBORHOOD PLAN: North Stone

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: July 26, 2005

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(XXXX) Resubmittal Required:
(XXXX) Tentative Plat
(XXXX) Development Plan
() Landscape Plan
() Other

REVIEWER: DCE 791-4505 DATE: 7/25/05
Department of Urban Planning and Design Comments
Stone Crossing Condominiums
S05-047

Since this is an RCP, it must be in conformance with the design policies and criteria of the North Stone Area Plan and the General Plan, and any of its components. The Design Guidelines Manual, which offers insight and clarification into land use and community design policies is also used as an additional resource to the General Plan.

Although the proposed development appears to have addressed landscaping and design elements along the site perimeter wall, the development plan does not indicate specific design treatment of the site perimeter wall. Please add a note to the General Notes section stating that all walls visible from a public right-of-way to be graffiti-resistant and to incorporate one or more visually appealing design treatments, such as; the use of two or more decorative materials like stucco, tile, stone, or brick; a visually interesting design on the wall surface.

Walls should be visually interesting when viewed from off-site. For reference, the applicable North Stone Neighborhood Plan policy reads as follows:

Soften the visual impact of a continuous solid mass, such as a wall of greater than 75 feet in length and three feet in height, by one or more of the following techniques:
vary the wall alignment (jog, curve notch, or set back, etc.), and plant trees or shrubs in the voids created by the variations.
plant trees and shrubs, which are proportional in scale to the proposed wall, at least every 25 feet.

The Design Guidelines Manual states that side and rear building facades should be built with attention to architectural character and detail comparable to the front façade, particularly if rear and side facades are visible from streets or adjacent properties. Enhancement can include design treatments such a pop outs, color variation, etc. Please submit elevations illustrating how this requirement will be satisfied for the units abutting N. Thurston, Lane, N. Stone Avenue and Limberlost Drive.
10/27/2005 DAN CASTRO ZONING REVIEW Approved
11/02/2005 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this TP/DP.

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
11/08/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed