Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S05-048
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S05-048
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/02/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/23/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-048 STONE CROSSING CONDOMINIUMS / FINAL PLAT
DATE: August 16, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1: Include the section, township and range on all Title Blocks.

2: Delete all street directions per letters dated 4/8/05 and 7/13/05.

3: Include a site plan of the occupant identifiers for condominiums per letters dated
4/8/05 and 7/13/05.
08/30/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: STONE CROSSING CONDOMINIUMS
S05-048

Tucson Electric Power Company has reviewed and approved the Final plat
submitted for review August 2, 2005.

In order to apply for electric service, call the New Construction Department
at (520) 770-2062. Submit a final set of plans including approved site,
offsite and electrical load plans. Include a CD with the AutoCAD version of
the plans. If easements are required, they will be secured by separate
instrument. Your final plans should be sent to:

Warren McElyea
Design/Build - DB 102
Tucson Electric Power Company
P. O. Box 711
Tucson, AZ 85702

Please call me at (520) 917-8745, should you have any questions.

Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
08/30/2005 JOSE ORTIZ ENGINEERING REVIEW Denied DATE: September 1, 2005

TO: Patricia Gehlen, CDRC Manager

FROM: Jose E. Ortiz, Civil Engineering

SUBJECT: Engineering review of the Stone Crossing Final Plat (40 Condominium Units). Activity # S05-048.

RESUBMITTAL REQUIRED: Final Plat, and Assurance Package

Engineering has reviewed the received items and does not recommend approval of the Final Plat. Final Plat cannot be approved until Tentative Plat has been approved. Submit with the following review package the Assurance Package.


1. Place the words "Book ____ Page ____" in both the upper and lower right corners outside the margin line. The blanks will be completed by the Pima County Recorder's Office at the time of recordation. DS 2-03.6.1.G

2. The S(YR)-___ subdivision case number assigned to the approved tentative plat and place in the lower right corner of the plat next to the title block. If the property is subject to a rezoning case, the C9-__-__ rezoning case number is to be noted also. DS 2-03.6.1.K

3. Provide a legend, which shows and describes all symbols used on the drawing will be placed on either the first sheet of the plat or the first sheet which contains all or part of the subdivision drawing. DS 2-03.6.1.L

4. 6.3 Final Plat Standard Paragraphs. The following statements will be provided on the final plat, as applicable. All signatures must be in permanent, black, india ink and be accompanied by a notary signature and seal. DS 2-03.6.3

5. Dedications. A DEDICATIONS paragraph is required and must be placed on the first page of the plat to the effect that all streets, alleys, easements, and other rights-of-way and any lands for public uses are dedicated by this plat to the public or for private use. The paragraph entitled DEDICATIONS consists of four (4) elements: a statement of certification of title; a dedication statement; a hold harmless clause; and a signature line(s) for the property owner(s). DS 2-03.6.3.B

6. If applicable, the following BENEFICIARY block must be included on the title page. DS 2-03.6.3.C

q BENEFICIARY
"The beneficiary of (Title Company Name and Trust Number) is (Name and Address)."

7. Many items are not shown in the final plat. Please refer to the Development Standards section 2-03.6.4 (Proposed Subdivision Information) and section 2-03.6.5 (Survey Information) to assist in determining what information is needed on the Final Plat.

8. In order to expedite the plat review and approval, provide the boundary survey and closure calculations report in accordance with D.S. 2-03.6.5.C.3.

9. Show detention/retention areas in a surveyable and readily retraceable manner. DS 2-03.6.4.I

10. New Common Areas should be created for the two retention basins to prevent confusion in the future in regards to the exact boundaries of the basins.

As mentioned above, many items from the Development Standards section 2-03.6.4 & 2-03.6.5 were not addressed. Do to the number of individual items missing from those two sections comments were not generated for this review. Please pay special attention to those sections and if you have any questions, I can be reached at 791-5640 ext. 1191 or jose.ortiz@tusconaz.gov

Jose E. Ortiz, PE
Civil Engineer
08/30/2005 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: August 30, 2005


RE: Assessor’s Review and Comments Regarding Final Plat
S05-048 STONE CROSSING CONDOMINIUMS (105-12)


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.






Jessica Shettleroe
09/01/2005 DAN CASTRO ZONING REVIEW Denied COMMENTS

1. An applicant has one (1) year from the date of approval of the tentative plat to obtain approval and recordation of a final plat that complies with zoning and other development requirements in effect at the time of application. Since the tentative plat for this subdivision has not yet been approved, the approval date for this final plat may not be determined. In addition, the final plat may not be approved prior to approval of the tentative plat. Since the tentative plat has not yet been approved, any revisions made to the tentative plat which effect the final plat must also be made to the final plat.

2. This plat has been assigned subdivision case number S05-048. Note the subdivision case number in the lower right corner of each sheet on all plans. (D.S. 2-03.6.1.K)

3. Under the general notes on sheet 1 of 7, the gross site area of the subdivision listed in acres is incorrect.

4. Provide a cubic volume calculation/matrix for each unit.

5. Dimension building cross sections in order to verify cubic volume.

6. Provide building ties. See Engineering comments for additional information required.


7. The CC&R's must be revised as follows: On the cover sheet please reference all the subdivision information found in the title block located on each sheet of the final plat (i.e. subdivision name, number of units, common areas, and RCP statement).

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180.
09/02/2005 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approv-Cond September 2, 2005

TO: E. Bruce Wilson, P.E., R.L.S.
Landmark Engineering, Inc.

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Stone Crossing, 40 Condominium Units and Common Areas A-D
Final Plat – 1st Submittal
S05-048


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


SHEET 1. Revise the fourth paragraph of the Dedication to read

TITLE TO THE LAND ALL COMMON AREAS SHALL BE IN VESTED IN AN ASSOCIATION OF INDIVIDUAL UNIT OWNERS AS ESTBLISHED BY COVENANTS, CONDITIONS AND RESTRICTIONS RECORDED IN DOCKET _______ AT PAGES ________, IN THE OFFICE OF THE PIMA COUNTY RECORDER. THIS ASSOCIATION WILL ACCEPT RESPONSIBILITY FOR CONTROL, MAINTENANCE, AD VALOREM TAXES AND LIABILITY FOR THE COMMON AREAS, PRIVATE STREETS, PRIVATE SEWERS AND PRIVATE EASEMENTS WITHIN THE SUBDIVISION.

SHEET 1. Show the trust number of the title company so that a revised sewer service agreement may be prepared for this project. Additionally, please confirm if Fidelity National Title Agency is in fact a California corporation and not an Arizona corporation.

A new set of drawings will not be required, however this final plat may not be approved until the three sewer service agreements are processed and item one of this review letter is complete. Additionally, review comments on the tentative plat/development plan need to be addressed as well.





If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
09/20/2005 FRODRIG2 COT NON-DSD REAL ESTATE Approved S05-048, Stone Crossing
No comment
09/21/2005 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 21, 2005

E. Bruce Wilson, P.E., R.L.S.
Landmark Engineering, Inc.
3845 North Business Center Drive, Suite 107
Tucson, AZ 85705

Subject: S05-048 Stone Crossing Condominiums Final Plat

Dear Bruce:

Your submittal of August 2, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

5 Copies Revised Final Plat (addressing, wastewater, zoning, engineering, DSD)

3 Copies Revised CC&R's (zoning, engineering, DSD)



Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 628-1392