Plan Number: S05-048
Parcel: Unknown

Review Status: Completed

Review Details: REVISION - FINAL PLAT REVIEW

Plan Number - S05-048
Review Name: REVISION - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/03/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/17/2006 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S05-048
Stone Crossing Condominiums
Final Plat Revision

TRANSMITTAL DATE: November 17, 2006

DUE DATE: December 5, 2006

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The configuration of the parking area south of the pool should match the tentative plat. Please revise.

2. On sheet 3 of 7 the private PAAL north of the pool area should match what is shown on sheet 2 of 7 and what is proposed on the tentative plat.

3. The previously approved plat has all PAALs marked as private streets as well as PAALs. Is there a reason why this is changed? Please address.

4. Common Area "B" and "D" appear to run together with no clear delineation. Please label and denote each common area with a solid line.

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197.

KAA S:\zoning review\karol\planning\cdrc\finalplat\S05-048fprev.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's and additional requested documents.
11/30/2006 JOSE ORTIZ ENGINEERING REVIEW Denied Due to the required revisions for the Tentative Plat the Final Plat cannot be approved at this time. Engineering needs to cross-reference the Final Plat against the Tentative Plat to confirm consistency between the two documents during the next re-submittal of the Tentative Plat.

If you have any questions or would like to meet with me before your next submittal, you may contact me at 791-4259 ext.305 or Jose.Ortiz@tucsonaz.gov
12/01/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

December 1, 2006

E. Bruce Wilson, P.E., R.L.S.
Landmark Engineering, Inc.
3845 North Business Center Drive, Suite 107
Tucson, AZ 85705

Subject: S05-048 Stone Crossing Condominiums Revised Final Plat

Dear Bruce:

Your submittal of November 3, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Final Plat (Zoning, Engineering, DSD)







Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 628-1392