Plan Number: S05-048
Parcel: Unknown

Review Status: Completed

Review Details: REVISION - TENTATIVE PLAT REVIEW

Plan Number - S05-048
Review Name: REVISION - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/03/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/17/2006 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S05-048
Stone Crossing Condominiums
Tentative Plat Revision

TRANSMITTAL DATE: November 17, 2006

DUE DATE: December 5, 2006

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Through out the plan notes are superimposed over each other. Notes, lot numbers, FFE, keynotes, bearings, and detail indicators are affected. This appears to be happening on all sheets. Please correct all notes, on all sheets that are unreadable.

2. Please provide the width of the parking space adjacent to the wall on the south side of the pool area. When the sides of a parking space abuts any vertical barrier over six (6) inches in height, the required width of that space is ten (10) feet. Maneuvering ability in and out of this space is to be demonstrated on the plan.
DS 3-05.2.1.B.2

3. Please dimension the handicap access aisle located south of the pool area. Minimum width is to be eight (8) feet.

4. Please provide a label for the enclosed area at the end of the PAAL abutting Limberlost. Is this a trash enclosure?


If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197.

KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S05-048tp.doc


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat and additional requested documents.
11/21/2006 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S05-048 Stone Crossing Condominiums 11/20/06

(XXXX) Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-84-51 – Conditions Not Met
C9-89-26 – Conditions Not Met
C9-80-68 - Annexation

NEIGHBORHOOD PLAN: North Stone

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 12/05/06

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
(XXXX) RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
(XXXX) No Additional Comments - Complies With Planning Comments Submitted on: 11/01/05
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: DRC 791-4505 DATE: 11/09/06
11/28/2006 JOE LINVILLE LANDSCAPE REVIEW Denied Submit a revised landscape plan. DS 2-07.2.0
11/29/2006 JOSE ORTIZ ENGINEERING REVIEW Denied DATE: NOVEMBER 30, 2006

TO: Patricia Gehlen

FROM: Jose E. Ortiz, PE

SUBJECT: Tucson Roger Subdivision
TENTATIVE PLAT (THIRD REVIEW)
JobS05-138 T13S, R14E, Sec 29

RESUBMITTAL REQUIRED: Tentative Plat

Please attach a response letter with the next submittal, which states how all Engineering/Floodplain/Solid Waste Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The drawings appear to have excessive layers on creating over lap in text. Please re-visit drawings and turn off unneeded layers on each sheet. Ensure that proper text height is used for reproduction purposes, eliminate overlap in text, remove leaders/callouts that point to empty space, etc…

2. Many of the Common Areas in the Tentative Plat do not match the Final Plat, for example Common Area E in the final plat appears to be mislabeled and is being call out as common area A in the Tentative Plat. Please revise.




If you have any questions or would like to meet with me before your next submittal, you may contact me at 791-4259 ext.305 or Jose.Ortiz@tucsonaz.gov
12/01/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

December 1, 2006

Bruce Wilson
Landmark Engineering
3845 N. Business Center Drive
Tucson, AZ 85705

Subject: S05-048 Stone Crossing Condominiums Revised Tentative Plat

Dear Bruce:

Your submittal of November 3, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

4 Copies Revised Tentative Plat (Landscape, Zoning, Engineering, DSD)

4 Copies Revised Landscape Plan (Engineering, Landscape, Zoning, DSD)










Should you have any questions, please call me at 791-5608, ext 1179.

Sincerely,

Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 628-1392