Plan Number: S05-043
Parcel: Unknown

Review Status: Completed

Review Details: OTHER SUBDIVISION REVIEW

Plan Number - S05-043
Review Name: OTHER SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/18/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/22/2005 JIM EGAN COT NON-DSD FIRE Denied Minimum 20 feet wide, paved, fire apparatus access roadway must be provided and extended to within 150 feet of all portions of the exterior walls of all structures. An approved turnaround is required for dead-end access roadways.
03/25/2005 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved NO COMMENT
S05-043
A. C. Tsang Engineering Group, Inc.
LECOCO/BLACKLIDGE APARTMENTS
04/06/2005 FRODRIG2 PIMA COUNTY WASTEWATER Denied April 5, 2005

TO: Antony C. Tsang
A. C. Tsang Engineering Group, Inc.

THRU: Craig Gross
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: LeCocq/Blacklidge Apartments
Subdivision Exception – 1st Submittal
S05-043


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


This project will be tributary to the Roger Road Wastewater Treatment Facility and Ina Road Water Pollution Control Facility via the South Rillito Central Interceptor. Provide a letter from PCWWM Planning Services, written within the past 90 days, stating that treatment and conveyance system capacity for this project is available. Contact Robert Decker, PCWWM Planning Services, at (520) 740-6625 regarding this matter.

Based on the evaluation of historical records, this project would qualify for Participating sewer connection fee rates.

ALL SHEETS. Add the project number, S05-043, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

This project is required to supply all necessary sewer design information per the subdivision coordination checklist. Please access http://www.pimaxpress.com and follow the requirements of the checklist to provide the proper layout and general notes for the sewer. An additional sheet may be necessary for this layout. Review comments will be provided after the 2nd submittal of this project.

We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents.

The next submittal of this project will be the 2nd submittal. A check for the review fee of this submittal in the amount of $50.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.

If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
04/11/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: LECOCQ/BLACKLIDGE APTS
S05-043

Tucson Electric Power Company has reviewed and approved the Land Survey
Exception-Lot Split Plans dated March 11, 2005.

Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
04/11/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-043 LECOCO/BLACKLIDGE APARTMENTS/OTHER SUB REVIEW
DATE: April 7, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Change Flanwill Avenue to Boulevard.

Recorded deeds with legal descriptions will be required in order to split property.















jg
04/11/2005 JCLARK3 ENV SVCS REVIEW Denied The project is existing buildings that are being renovated under T04CM00843. Plan approved with an enclosure for refuse at the front of the property. Location of the enclosure does not provide sufficient space for the trucks to manuever to pick up the dumpster out of the enclosure. There is time to adjust the parking to allow a turnaround to be made for a direct front loading service. This would require the turnaround to be made directly to the west of the enclosure.
04/13/2005 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
Lecocq/Blackledge Apartments Record of Survey
S05-043

TRANSMITTAL: April 13, 2005
DUE DATE: April 15, 2005


1. The submitted survey is being reviewed as a Record of Survey.

2. Place the S05-043 case number in the lower right hand corner of the plan next to the title block.

3. Provide lot coverage calculations for each of the three developed parcels per LUC 3.2.9. The maximum allowed lot coverage in the R-2 zone with multiple units is 75 %.

4. Provide information regarding the heights of exterior
building walls along each side of the apartment buildings.
Setbacks cannot be verified until building heights are specified.

5. As indicated in the legal descriptions, a cross access and parking agreement will be required to allow access to parcels 1 and 3 to be across parcel 2, to allow pedestrian access to parcel 2 across parcels 1 and 3, and to allow the required parking for parcel 2 to be on parcels 1 and 3. Provide a copy of recorded agreement. Reference the recordation info (docket and page) on the drawing as a note.

6. List the names, addresses, and telephone numbers of the primary owners of the site.

7. All proposed easements (utility, sewer, drainage, access, etc.) are to be dimensioned and labeled as to their purposes and whether they will be public or private. Recordation information (docket and page) must be included on the plan prior to final approval.
DS 2-03.11

8. Add wheelstop curbing in the parking spaces as was shown on the preliminary drawing provided at the presubmittal meeting.

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
04/13/2005 JOE LINVILLE LANDSCAPE REVIEW Approved
04/14/2005 DALE KELCH COT NON-DSD TRAFFIC Denied >>> Dale Kelch 04/14/2005 10:54:18 AM >>>
Traffic Engineering REJECTS this other subdivision review:

1. The access point to this subdivision shall have 18' radius curb returns vice the standard driveway apron as depicted on the submitted plan set.

2. Show and label as to size (ie 20-110) the SVTs at the access point to the site.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
04/15/2005 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: April 15, 2005

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks, Parks and Recreation

SUBJECT: CDRC Transmittal, S05-043 Lecoco/Blacklidge Apartments: Other Subdivision Review


CC: Craig Gross, Development Services


No comments.





Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov
04/18/2005 PATRICIA GILBERT ENGINEERING REVIEW Denied TO: Craig Gross; CDRC Coordinator DATE: April 18, 2005

SUBJECT: Engineering review of the Lecocq/Blacklidge Apartments, Record of Survey. The activity number is S05-043.

SUMMARY: The Record of Survey was received by Engineering on March 21st, 2005. Engineering has reviewed the received items and does not recommend approval of the Record of Survey.

RESUBMITTAL REQUIRED: RECORD OF SURVEY


RECORD OF SURVEY COMMENTS

The next submittal must address the following items:

1. List the name, address, and telephone number of the person, firm or organization that prepared the record of survey. DS 2-03.11.8.

2. At least one corner of the property will be tied by a course and distance to a section corner, a quarter section corner, or an established City or County survey monument. The plan must include a description of that corner marker and an indication of how the bearings were determined. Corner tie recordation information is to be provided on the plan. DS 2-03.11.10.A.

3. Basis of bearings - The purpose of the basis of bearings on a survey is to enable another surveyor to retrace the original survey. As such, the statement must be referenced to found, readily locatable monuments. There are three general methods of establishing bearings.

a. Reference to a record of survey or a recorded plat.
b. Astronomic (normally solar or polaris).
c. Assumed.

The basis of bearings should be established from two (2) found, physically monumented points described and shown on the plan. If the monuments at each end of the reference line are fully described on the plan, they need not be described in the "Basis of Bearings" statement. DS 2-03.10.C.1.

4. Show the bearings between all monuments used. Indicate whether measured or calculated. Measured is the physical, direct occupation of a point/line by line of sight and not through calculations of other measured distances. Revise the plan. DS 2-03.10.C.4.

5. If applicable, identify all easements of record on the plan, with the recordation information, locations, widths, and purpose of the easement. DS 2-03.11.11.A.

6. Provide the recordation data (docket and page) for the existing public ROW. DS 2-03.11.11.B.

7. All proposed easements (utility, sewer, drainage, access, etc.) are to be dimensioned and labeled as to their purposes and whether they will be public or private. Recordation information (docket and page) must be included on the plan prior to final approval. DS 2-03.11.12.A.

8. Describe found monuments. Include the RLS number.
04/18/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S05-043 Le Cocq Blacklidge Apartments 04/15/05

() Tentative Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
(xxxxx) Other (Record of Survey)

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Grant Alvernon Area Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: April 15, 2005

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

(xxxxx) No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: Vania Fletcher 791-4505 DATE: 04/08/05
04/20/2005 FRODRIG2 OTHER AGENCIES PIMA ASSN OF GOVTS Approved Transportation Information for
Rezoning, Subdivision, and
Development Requests
Delivered to:
Date Delivered:
Development Services - City of Tucson
4/15/2005
Case Number Project Name
Estimated Daily Traffic
(in average 24-hour vehicle trips)
S05-043 Lecoco/Blacklidge Apartments 20
Pima Association of Governments
Transportation Planning Division
177 N. Church Ave., Suite 405, Tucson, Arizona
85701-1127
(520) 792-1093 FAX (520) 792-9151
04/28/2005 FRODRIG2 COT NON-DSD REAL ESTATE Approved No objection
04/29/2005 CRAIG GROSS ZONING-RECORDATION REVIEW Passed
04/29/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed