Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S05-029
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/31/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 11/13/2006 | KAROL ARAGONEZ | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: S05-029 Santa Rita Hotel and Condo Final Plat Resubmittal TRANSMITTAL DATE: November 13, 2006 DUE DATE: November 30, 2006 COMMENTS: The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 1. The streets shown within the location are too light and can not be read. Please darken. 2. Please remove the word easement that is superimposed over the words "the total" in general note E. 3. Tentative plat approval is required prior to final plat approval. DS 2-03.6.2. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197. KAA S:\zoning review\karol\planning\cdrc\finalplat\S05-029fpr.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat |
| 11/28/2006 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Denied | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Gary Ault, Mapping Supervisor Pima County Assessor's Office Mapping Department DATE: December 6, 2006 RE: Assessor's Review and Comments Regarding Final Plat S05-029 Santa Rita Hotel and Condo T141313 (117-17) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor's Office requirements.SEE COMMENTS _ ____ Plat does not meet Assessor's Office requirements. COMMENTS: Thank you for your submittal. This plat is approved pending the following adjustments are completed before recording. The plat really seems more like a development plat than a subdivision plat, but if that is how it is to be recorded, our office requires the following additions/corrections. 1. Remove hatching, striping and stippling. 2. There is a line missing on the west side of the plat, by the restaurant. 3. Add the names of the surrounding streets to sheet 2 and add the road information (were they established by map & plat, road maps or docket?). 4. Add bearings and dimensions for the buildings as well as the complete curve data. 5. Add the number of miles of new roads, public or private, to the general notes, even if the number is 0. 6. Are the long dash, double short dash lines the original lot line? If so, it needs to be a lighter line weight. The heaviest line weight should be the perimeter line, with the lot lines being the next heaviest. 7. Add the name(s) of the adjacent subdivision, with map and plat. 8. Add another sheet showing the bearings and dimensions of the condominiums. If there is only one typical style, that can be used instead of adding bearings and dimensions for each unit. If there are any questions, please contact Susan King at 740-4391. NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Susan King |
| 11/30/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | November 29, 2006 To: E. Bruce Wilson, P.E. Engineering and Environmental Consultants, Inc. . Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department From: Chandubhai C. Patel, P.E. Pima County Development Services Department Development Review Division (Wastewater) Subject: The Santa Rita Hotel and Condominiums Final Plat – 2nd Submittal S05-029 The proposed final plat for the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. 1. We will send to your office via e-mail, a pdf file containing a revised Sewer Service Agreement reflecting the proposed number of 148 residential and 66 retail condominium units. The revised SSA also reflects the new title insurance company. . Three originals will need to be printed out from this file for notarized signatures by the Owner of Record. The three signed originals of the Agreement must be returned to this office in order to satisfy the necessary requirements needed to approve the Mylars of the final plat. SUBJECT TO THE ABOVE, The Pima County Department of Environmental Quality and the Wastewater Management Department hereby approve the above referenced submittal of the Final Plat as received by us on October 31, 2006. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Chandubhai C. Patel, P.E. Telephone: (520) 740-6563 CC: Project File |
| 12/20/2006 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | DATE: December 20, 2006 To: Patricia Gehlen CDRC/Zoning Manager FROM: Loren Makus, EIT Engineering Division SUBJECT: Santa Rita Hotels and Condominium Final Plat S05-029 (Second Review) T14S, R13E, Section 13 RESUBMITTAL REQUIRED: Final Plat, The Plat has been reviewed by the Engineering Division and we do not recommend approval at this time. The following review comments must be addressed. The site plan information on this Plat was not reviewed at this time. The site plan information will be reviewed in the development plan process. 1. Perform quality checks on the plat. There are arrow leaders that do not point to the described features, overlapping text and text extending beyond the edge of the drawing. It might be helpful to remove the drawing features that don't present survey information. 2. Clearly show how the units are tied to the boundaries with distances and bearings. Clearly indicate on each affected drawing the location of the point establishing the local coordinate base and show how it is tied to the boundaries. 3. Explain sheet 2. There are areas labelled for various uses without boundaries indicated. 4. Clarify and confirm that the listed beneficiary is correct. Generally the beneficiary is separate from the title company. Submit a revised Plat. Include a detailed response letter, detailing how each comment has been addressed. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |
| 12/21/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES December 21, 2006 E. Bruce Wilson P.E. , R.L.S Landmark Engineering, Inc., 3845 North Business Center Drive, Suite 107 Tucson, AZ 85705 Subject: S05-029 Santa Rita Hotel and Condominium Final Plat Dear Bruce Your submittal of October 31, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 4 Copies Revised Final Plat (Assesor, Zoning, Engineering, DSD) Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 628-1392 |