Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S05-029
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/28/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/04/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 05/05/2006 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 05/12/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | May 11, 2006 To: E. Bruce Wilson, P.E., Landmark Engineering, Inc. Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department ____________________________________ From: Michael Harrington (520-740-6579), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: Santa Rita Hotel and Condominiums (The ) Tentative plat / Development plan 4th - Submittal S05-029 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Sheet 4: The 8” Sanitary Sewer Line Table and the L4 and L1 labels do not correspond with each other. Revised the line labels and table so that they relate to one another. Sheet 5: Keynotes #9, Existing Public Sewer Pipe and Structures, is not found anywhere on this site plan. Please clarify. Sheets 4 & 5: Private sewers are not allowed in public streets. Revise sheets 4 and 5 so that: The Russell Avenue abandonment notes that appear on sheet 3 also appear on sheet 4 and sheet 5. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat / development plan. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter CC: Project File |
| 05/26/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Denied | Right of way needs to be vacated for this subdivision. The Agreement for this vacation of right of way was sent out to the property owner on or about April 5, 2006. As of today's date the Real Estate Division has not received the signed Agreement. With out an Agreement we can not approve this final subdivision plat. |
| 06/03/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES June 3, 2006 Bruce Wilson Landmark Engineering 3845 North Business Center Drive Tucson, AZ 85705 Subject: S05-029 Santa Rita and Condominiums Tentative Plat Dear Bruce: Your submittal of May 1, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 3 Copies Revised Tentative Plat (Real Estate, Wastewater, DSD) Should you have any questions, please call me at 791-5608, ext 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 628-1392 |