Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S05-025
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/17/2007 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-025 CIVANO BLOCK 2/REVISED FINAL PLAT DATE: 1/17/07 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Creosote Point Lane may be confused with Creosote Ridge Way in the same subdivision. Can another street name be used? es |
| 01/29/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: January 29, 2007 CDRC/Zoning Manager SUBJECT: Civano Block 2 FP Final Plat S05-025 (Third Review) T14S, R15E, Section 01 RESUBMITTAL REQUIRED: Final Plat. The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Final Plat: 1. The submitted CC & R's do not appear to be prepared for Civano Block 2. The Recitals state that the CC & R's are for Blocks 79 through 82 that were recorded in Book 50 of Maps and Plats at Page 56, records of Pima County Recorder. The subject development is described in the Final Plat Title Block as "A resubdivision of Block 2 of Civano I, Lots 166-527, Bk. 52, Pg. 84 M&P". It appears that the existing CC & R's need to be amended to include the subject development. 2. The drainage structures maintenance, by the neighborhood association, has not been addressed properly in the CC & R's. The amendment shall include detailed information and instructions for maintaining the drainage structures. It is recommended to include the drainage structure maintenance checklist, as an exhibit, to the CC & R's. 3. Both comments were not addressed with this submittal. Perhaps a meeting to go over the comments would help in approving the FP. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/Civano Block 2 FP 3 |
| 01/31/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES January 31, 2007 Pattie Davis MMLA 800 E. Wetmore Road, #110 Tucson, AZ 85719 Subject: S05-025 Civano Block 2 Final Plat Dear Pattie: Your submittal of December 15, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 3 Copies Revised Final Plat (Addressing, Engineering, DSD) PLEASE NOTE THAT THIS FINAL PLAT MUST BE APPROVED BY MAYOR AND COUNCIL AND RECORDED PRIOR TO MARCH 5, 2007 PER LUC 4.1.7.3 (TENTATIVE PLAT WAS APPROVED ON MARCH 6, 2006). Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 292-1290 |
| 12/14/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/20/2006 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: CIVANO, BLOCK 2 Lots 1-28 S05-025 The Final Plat for the subject project will meet this Company's easement requirements. Please forward any resubmittals of the final plat to this office. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo, Right of Way Agent Land Management Tucson Electric Power Co. Unisource Energy Gas & Unisource Energy Electric PH: (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |