Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S05-025
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/13/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 06/22/2006 | PETER MCLAUGHLIN | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Peter McLaughlin Senior Planner FOR: David Rivera Principal Planner PROJECT: Civano Block 2 S05-025 Final Plat TRANSMITTAL: June 22, 2006 DUE DATE: July 12, 2006 The Zoning Review Section at the Development Services Department approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. COMMENTS: 1. Revise the dates in the Approvals and Recording Blocks to read "2006". If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 07/10/2006 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | FINAL PLAT The Final Plat has been reviewed. The Final Plat is recommended for approval pertaining to Engineering and Floodplain. CC & R's The CC & R's are not acceptable for this project. Address the following comments: 1. The submitted CC & R's do not appear to be prepared for Civano Block 2. The Recitals state that the CC & R's are for Blocks 79 through 82 that were recorded in Book 50 of Maps and Plats at Page 56, records of Pima County Recorder. The subject development is described in the Final Plat Title Block as "A resubdivision of Block 2 of Civano I, Lots 166-527, Bk. 52, Pg. 84 M&P". It appears that the existing CC & R's need to be amended to include the subject development. 2. The drainage structures maintenance, by the neighborhood association, has not been addressed properly in the CC & R's. The amendment shall include detailed information and instructions for maintaining the drainage structures. It is recommended to include the drainage structure maintenance checklist, as an exhibit, to the CC & R's. |
| 07/12/2006 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-025 CIVANO BLOCK 2/REVISED FINAL PLAT DATE: 7/12/06 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Change Mira Place to Lane. Pantano View has been reserved for another project. Please choose a new street name. Spell out all street suffixes except on Location Map. es |
| 07/20/2006 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: CIVANO, BLOCK 2 Lots 1-28 and Block A S05-025 Enclosed is Tucson Electric Power Company's (TEP) preliminary electrical design for the subject subdivision. TEP is unable to approve the final plat at this time. Please review this design and contact this office with any conflicts or desired changes. Your written approval of this design and TEP's final plat approval are necessary for a final construction drawing. Any changes requested after we have completed the final construction drawing will be billable. In order for TEP to approve the final plat, the following easements will be required: * A 10 wide easement is required along the western boundary of Block "A" and Lot 28 as highlighted. * Depict a 16' wide easement for the existing overhead line within Lot 1 and Common Area A. All relocation costs will be billable to the developer. A copy of the preliminary design has been forwarded to Southwest Gas. Please insure utility coordination by providing a copy of this preliminary design to Qwest and the Cable Company. Should you have any questions, please contact me at (520) 917-8745. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |
| 07/21/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES July 21, 2006 Pattie Davis MMLA 800 E. Wetmore Road, #110 Tucson, AZ 85719 Subject: S05-025 Civano Block 2 Final Plat Dear Pattie: Your submittal of June 13, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 4 Copies Revised Final Plat (TEP, addressing, engineering, DSD) 2 Copies Revised CC&R's (Engineering, DSD) Should you have any questions, please call me at 791-5608 ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 292-1290 |