Plan Number: S05-012
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S05-012
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/26/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
05/06/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-012 LIBERTY VILLAGE/FINAL PLAT
DATE: 05/05/05



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Change Lakeside Business Park, Phase II to Lakecrest Business Park, Phase II on all Title Blocks.

Spell out Parkway of Lakeside Pw on key map per letter dated 4/18/05.

The street adjacent to lot 1 and CA “C” will require a street name per letter dated 4/18/05.

Change file S05-112 to S05-012 on all pages.

Label Lakeside Parkway (western portion) on Key Map.

Label Republic Avenue on pg. 3.

Label Senate Street on pg. 4.

Change Poantano Road to Pantano on pg. 4.
05/16/2005 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 05/16/2005,

SUBJECT: Liberty Village
S05-012, T15S, R14E, SECTION 28

RECEIVED: Final Plat, CC & R's and Assurances on April 26, 2005

The subject project has been reviewed. We offer the following comments:

1. Provide the correct S05-XXX Case Number in the Title Block (D.S. 2-03.6.1.k).
2. The DEDECATION Block is missing the Trust Number.
3. The BENEFICIARY Block is missing the Trust Number (D.S. 2-03.6.3.C).
4. The BENEFICIARY Block is missing the correct address.
5. Place the words "BOOK_________ PAGE_________" in both the upper and the lower right corners outside the margin line as required by D.S. 2-03.6.1.G.
6. Add a symbol in the Legend for the SET MONUMENTS.
7. Number all General Notes.
8. Revise the "Floodplain Use Permit" note to state that "Prior to issuance of any building permit, a Floodplain Use Permit is required for the proposed fill and construction of drainage facilities in the existing regulatory 100-year floodplain. The Developer is required to acquire the Floodplain Use Permit, with the Grading Plan Permit, for any proposed work in the said 100-year floodplain, which would result in the floodplain containment and the removal of proposed lots, within the flooded areas, from the regulatory floodplain". The purpose of this comment is clarify on the plat that floodplain use permits will not be required for the impacted individual lots when they come in for permitting (D.S. 2-03.6.2.E.).
9. Since this project does not propose any new public streets and/or drainageways, replace the word "Public" by "Private" in the second paragraph of the dedication.
10. Add the words "Private Streets" in the second paragraph, in the "Title to the Land" and "The Association will accept responsibility" statements.
11. The "1' No Vehicular Access Easement" to be abandoned by the subject Plat must be legally delineated/described to separate it from the "1' No Vehicular Access Easement" to be dedicated by the Plat.
12. Clarify what the square, shown in the northeast corner of Common Area "C", between lots 6 and 7, is.
13. Show all the required monuments for the entrances returns and the common areas (D.S. 2-03.6.5.).
14. Show required erosion hazard setback lines as required by D.S. 2-03.6.4.E.
15. Show the limits of the 100-year floodprone area in a surveyable and readily retraceable manner as required by D.S. 2-03.6.4.F.
16. Show the existing 30' ingress/egress and P.U.E. shown on the Plat that was approved under case # S00-006 (D.S. 2-03.6.5.B.).
17. Show the distance and bearing between all monuments used. Indicate whether measured or calculated as required by (D.S. 2-03.6.5.C.5).
18. Submit a copy of the CC & R's for review. The CC & R's should specifically address the drainage facilities maintenance. This Office recommends including the maintenance checklist in the CC & R's to allow the owners' association access to it and to facilitate their maintenance responsibility (D.S. 2-03.6.6.).
19. The Assurances package is acceptable. Submit all the required supporting documents with the Original Assurances package.

Prepare a detailed response that explains the revisions that were made and references the exact location on the Final Plat where the revisions were made.


RESUBMITTAL REQUIRED: Revised Final, CC & R's and Assurances

LFA:lfa
05/18/2005 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
Liberty Village
S05-012
Final Plat

TRANSMITTAL: May 18, 2005
DUE DATE: May 23, 2005

1. The case number listed in the lower right hand corner is incorrect. Revise the subdivision case number to read "S05-012". DS 2-03.6.1.K

2. Tentative Plat approval is required prior to final plat approval.
DS 2-03.6.2

3. Some of the set monument pin symbols have been left off the drawing. Revise plat drawings to show the location of all monuments, including the southwest corners of lots 31 (sheet 4 of 4) and 81 (sheet 3 of 4) and provide the symbol in the legend. DS 2-03.6.5

4. Remove the adjacent zoning indicators from sheet 1 of 4 on the final plat. DS 2-03.6.1.H

5. The words "BOOK_________ PAGE_________" must be placed in both the upper and the lower right corners outside the margin line. D.S. 2-03.6.1.G

6. For ease of reference the general notes must be numbered.

7. Provide a copy of CC&R's for the subdivision. DS 2-03.6.6

8. Add the trust number and complete address of the Title Company to the Beneficiary Block and the trust number to the Dedication Block. DS 2-03.6.3.C


If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
05/20/2005 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: May 18, 2005


RE: Assessor’s Review and Comments Regarding Final Plat
S05-12 Liberty Village T151428 (136-15)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal. Please correct the spelling of Pantano of sheet 4 before recording this plat.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.







Susan King
05/31/2005 MARILYN KALTHOFF COT NON-DSD REAL ESTATE Approved
06/08/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: LIBERTY VILLAGE
Lots 1-94
S05-012

Tucson Electric Power Company (TEP) has received the final plat for
submitted for review April 26, 2005. This Company is unable to approve the
plat at this time.

TEP is in the process of completing the preliminary electrical design. When
it is completed we will send you the design and our easement requirements.
Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
06/09/2005 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond May 12, 2005

TO: Derek Roberts
Arcadis

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Liberty Village, Lots 1-94 and Common Areas A-C
Final Plat – 1st Submittal
S05-012


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


ALL SHEETS. Revise the project number to reflect S05-012.

SHEET 2. Delete the public sewer easement as Pima County Wastewater Management Department no longer requires public sewer easements across common areas since they are granted as easements in the Dedication.

A public Sewer Service Agreement for the proposed number of residential lots has been sent to your office. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals should be returned to Pima County Wastewater Management in order to satisfy the necessary requirements needed to approve the Mylars of the final plat.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
06/10/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed