Plan Number: S05-012
Parcel: Unknown

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Plan Number - S05-012
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/26/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/27/2005 JIM EGAN COT NON-DSD FIRE Approved The Tentative Plat is approved January 27, 2005.
02/01/2005 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved NO COMMENT
S05-012
ARCADIS
LIBERTY VILLAGE
02/02/2005 JCLARK3 ENV SVCS REVIEW Approved * No known landfill with in 1000 feet of this development.
* Approved for APC's pickup off the private street. APC's to be paced and removed from the collection area on the collection day.
02/09/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: LIBERTY VILLAGE
Lots 1-94
S05-012

Tucson Electric Power Company (TEP) has reviewed the tentative plat dated
January 3, 2005. This Company is unable to approve the plat at this time.
There are existing electrical facilities along Golf Links Road and Lakeside
Parkway. The facilities must be shown on the plat prior to approval.

A copy of TEP's facility map showing the approximate location of the
existing facilities is enclosed. There is an existing service to a
billboard; contact Frank Grijalva, Design Build Department at (520) 918-8361
regarding the removal of this service.

TEP will provide a preliminary electrical design on the Approved Tentative
Plat within fifteen (15) working days upon receipt of the plat. Additional
plans necessary for preparation of the design are: building plans including
water, electrical, landscape, sidewalk and paving plans. Should you have
any questions, please contact me at (520) 917-8745.



Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8745
Cell Phone: (520) 904-2668
Fax: (520) 917-8700
02/09/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-012 LIBERTY VILLAGE / TENTATIVE PLAT
DATE: FEBRUARY 9, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1: Change 17-05 to 17-04 and 30-50 to 35-50 on Location Map.

2: Change the suffixes of Republic Street and Democracy Street to Avenue, Drive, Lane,
Road, Trail or Way. Street is reserved for east-west streets.

3: Spell out all street suffixes except on Location Map.

4: Correct Matchlines on pgs 2-4. They do not match Key Map.

5: Change Golf Links & Pantano Business Park Bk 35, Pg 50 to Bk 42, Pg 74 on Pg. 4.

6: Change Revolution Circle to Loop.
02/22/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S05-012 Liberty Village 02/18/05

(XXXX) Tentative Plat
() Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
(XXXX) Other – NPPO Plan

CROSS REFERENCE: C9-70-100

NEIGHBORHOOD PLAN: South Pantano

GATEWAY ROUTE: Golf Links

COMMENTS DUE BY: 02/24/05

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
(XXXX) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(XXXX) Resubmittal Required:
(XXXX) Tentative Plat
() Development Plan
(XXXX) Landscape Plan
(XXXX) Other – Color Palette

REVIEWER: DCE 791-4505 DATE: 02/18/05
Urban Planning and Design Comments
S05-012 Liberty Village

Because this is a Residential Cluster Project (RCP), it must be in conformance with Section 3.6.1 of the Land Use Code as well as the design policies and criteria of the General Plan, and any of its components, including the South Pantano Area Plan and the Design Guidelines Manual. Allowance of the RCP is based on the purpose to provide greater flexibility and creativity in the design of the clustered residential developments.

The General Plan and Design Guidelines Manual state streetscapes should provide a pleasant microclimate for pedestrians through the placement of trees along subdivision streets. A minimum of one 15-gallon tree, on every other lot to shade pedestrian areas can meet this requirement. Additionally, ground vegetation should be provided on each individual lot using new vegetation and existing, mature vegetation that is transplantable. Please show these additions on the landscape plan.

The Design Guidelines Manual states that detention/retention basins should be used for open space and, as additional active or passive recreational amenities accessible to the handicapped. Please locate amenities such as; picnic tables, benches, barbecue, tot lot, shaded sitting area(s). etc. in the detention/retention areas.

The intention of an RCP is to allow greater flexibility and creativity in design. The location and the size of this project, lends itself for creative and enhanced design. The General Plan and the Design Guidelines Manual address the importance of development that uses colors of the natural environment which include a variety of blended shades such as blues, yellows, oranges, greens, purples and reds. Applying a variety of these colors to this RCP would not be inconsistent with the variety of colors currently surrounding the area. Please provide a color palette to demonstrate how this will be incorporated. Also, please make a note on the plat that no two homes with the same façade or color scheme shall be placed adjacent to one another.

Please provide a note or detail indicating that any required or proposed masonry screen walls shall be constructed of, or painted with, graffiti-resistant materials. These screen walls shall incorporate one of the following decorative materials: a) tile, b) stone, c) brick, d) textured brick/block, e) a coarse-textured material such as stucco or plaster, or f) a combination of the above materials. In addition, any continuous wall greater than 75 feet in length and three feet in height visible from the public right-of-way shall vary the wall alignment (jog, curve, notch, or setback, etc.) and include trees or shrubs in the voids created by the variations.

6. The General Plan, and Design Guidelines Manual promote connectivity and accessibility to and from adjacent areas. Please provide connectivity and accessibility to the commercial uses to the south of the RCP either from Revolution Circle or from Common Area C west of Republic Street.
02/22/2005 FRODRIG2 OTHER AGENCIES PIMA ASSN OF GOVTS Approved Transportation Information for Rezoning,
Subdivision and Development Review Requests
File Number Description Date Reviewed
E
Pima Association of Governments
Transportation Planning Division
177 N. Church Avenue, Suite 405
Tucson, AZ 85701
Phone: (520) 792-1093
Fax: (520) 792-9151
www.pagnet.org
S05-012 Liberty Village: Tentative Plat Review 2/22/2005
1. Nearest Existing or Planned Major Street
2. Is improvement planned as part of the 5-Year Transportation Improvement Program
Planned Action:
STREET IDENTIFICATION
3. Existing Daily Volume – Based on Average Daily Traffic
4. Existing Daily Capacity- Level of Service “E”
5. Existing Number of Lanes
9. Estimated Traffic Generation for Proposed Development
(Expressed in Average 24 Hr. Vehicle Trips)
8. Future Number of Lanes
TRANSIT AND BIKEWAYS CONSIDERATIONS
10. Present Bus Service (Route, Frequency, Distance)
11. Existing or Planned Bikeway
Remarks:
Street Number 1 Street Number 2
Year Year
Planned Action:
VOLUME/CAPACITY/TRAFFIC GENERATION CONSIDERATIONS
6. Future Daily Volume - Adopted Plan System Completed
7. Future Daily Capacity - Level of Service “E”
Golf Links Rd (Pantano Rd to Pantano Parkway)
No 0
27,600
63,000
6
63,000
36,143
6
900
Route 17, 30 minutes, 0 miles
Bike route with striped shoulder
0
0
0
0
0
0
0
02/23/2005 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond February 23, 2005

TO: Derek Roberts, P.E.
Arcadis

THRU: Craig Gross
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Liberty Village, Lots 1-94 and Common Areas A-D
Tentative Plat – 1st Submittal
S05-012


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


This project will be tributary to the Ina Road Water Pollution Control Facility via the Pantano Interceptor. Provide a letter from PCWWM Planning Services, written within the past 90 days, stating that treatment and conveyance system capacity for this project is available. Contact Robert Decker, PCWWM Planning Services, at (520) 740-6625 regarding this matter.

Based on our evaluation of projects S00-006 and I-82-34, this project would qualify for Non-Participating sewer connection fee rates for lots 25-50, 75, 76 and 91-94 and Participating sewer connection fee rates for lots 1-24, 51-74 and 77-90.

ALL SHEETS. Add the project number, S05-012, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

Your submittal included payment of $466 which is the review fee for six sheets. However, your submittal drawings included seven sheets, thus the correct review fee is $516. Please submit a check for $50.00 made out to Pima County Treasurer.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
02/24/2005 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 02/24/2005

DATE: February 24, 2005

TO: Craig Gross FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Liberty Village
S05-012, T15S, R14E, SECTION 28

RECEIVED: Tentative Plat, Landscape Plan and Drainage Report on March 17, 2004

The subject project has been reviewed. We offer the following comments:

Drainage Report:

1. Show CP7 on Exhibit 2.
2. Verify that the proposed streets have the capacity to contain the onsite runoffs.
3. According to Section 2.3 of the "Storm Detention/Retention Manual" storm-water detention requirements can be waived if the project satisfies either Criterion 1 or Criterion 2 as described in the Manual. The subject project does not appear to satisfy either criterion. Subsequently, detention can not be waived for this project.
4. Change the reference to "retention" only in the report.
5. It is not clear what conveyance system will be under the site entrance (i.e. 10' X 4' RCBC, 5' X 36" RCP or 2 X 36" pipes).
6. Verify if this project is required to be in compliance with the 404 permit requirements.
7. Show on the drainage exhibits the location of the existing 24" RCP and 30" RCP. Additionally, verify that both pipes are RCP's. Based on a field visit to the site, it appears that one of the pipes is a corrugated metal pipe. Verify this information and revise the report as necessary.
8. Show on the drainage exhibits the location of the 5 X 36" RCP's and the 2 X 36" RCP's.
9. Address any erosion and scour mitigation measures that may be needed at the proposed drainage structures and basins inlets and/or outlets.
10. Address sediment traps or other sediment control measures in all the proposed detention/retention basins to demonstrate compliance with Section 3.4 of the Stormwater Detention/Retention Manual.
11. The lot numbers shown on Scupper 2 Calculation Sheet are wrong. Revise.
12. It is not clear why Q10 was used to size the curb opening for ON1D. Revise the calculations by using Q100. Additionally, provide the design calculations for the proposed channel downstream of the proposed curb opening.
13. The HEC RAS analysis shows that Channel one and Channel two will have runoff velocities that will exceed 4.00 feet per second. Address scouring in Channel one and propose means for scour protection.
14. Address water harvesting.
15. According to Section 14.3 of the "Standard Manual for Drainage Design and Floodplain Management In Tucson, Arizona", the maintenance access ramps should be wide enough to accommodate vehicular access. The minimum width should be 15' and the ramp slope should not exceed 15 percent. Please be advised that maintenance ramps should be designed in such a way that does not allow access to vehicles except maintenance vehicles. Verify that the provided maintenance ramps conform to the requirements.
16. Determine the proposed slope treatment and setback lines from the proposed basins and channels (including Channel 1) based on the Soils Report recommendations.
17. Verify that the proposed retention basins have an acceptable percolation rate or provide them with bleed pipes to ensure that water will not stand for prolonged periods of time.
18. The detention/retention basin bottoms must be graded to provide positive drainage to prevent nuisance ponding.
19. Show on the onsite drainage map the proposed detention/retention basin side slopes, maintenance access ramps, and dimensions including depth and the 100-year water surface elevation. Verify that security barriers are not required.
20. This Office recommends including the maintenance checklist in the CC & R's to allow the owners' association access to it and to facilitate their maintenance responsibility.

Tentative Plat/Development Plan:

1. Provide the correct S (yr)-______ subdivision case number according to D.S. 2-03.2.2.B.1.
2. Add a general note stating that part of the subject parcel is affected by the City of Tucson floodplain regulations (D.S. 2-03.2.2.C.2.a.).
3. Add a general note, which states that the depicted "existing 100-year floodplain", which impacts the areas where lots are proposed, shall be removed or contained within the proposed drainage facilities once they are constructed and completed. Additionally, add a note that requires the Developer to acquire a Floodplain Use Permit, with the Grading Plan, for any proposed work in the said 100-year floodplain, which would result in the floodplain containment. The purpose of this comment is clarify on the plat that floodplain use permits will not be required for the impacted individual lots when they come in for permitting (D.S.2-03.2.2.C.2.b.).
4. Show all existing easements as required by D.S.2-03.2.3.C. It appears that there is a 30' ingress/egress and P.U.E. shown on the Plat that was approved under case # S00-006.
5. Add the "All weather access shall be provided for this subdivision" note to the General Notes.
6. Show all required setback lines including Sight Visibility Triangles (SVT's) and proposed channels and detention/retention basin setbacks as determined by the Geotechnical Report (D.S. 2-03.2.4.M.). Ensure that the proposed patio walls and retaining walls do not encroach on the SVT's.
7. Submit a Geotechnical Report that addresses drainage setback lines and slope protection. Demonstrate compliance with the Geotechnical Report on the Tentative Plat.
8. Show the proposed detention/retention basin inlet and outlet erosion control measures. Additionally, show the required detention basin Sediment Control Structures (D.S. 2-03.2.4.L.3). Additionally, include the sizes of the proposed sidewalk scuppers.
9. Show the width and the slope of the proposed detention basins access ramps. According to Section 14.3 of the "Standard Manual for Drainage Design and Floodplain Management In Tucson, Arizona", the maintenance access ramps should be wide enough to accommodate vehicular access. The minimum width should be 15' and the ramp slope should not exceed 15 percent. Please be advised that maintenance ramps should be designed in such a way that does not allow access to vehicles except maintenance vehicles.
10. It appears that there should be an erosion control structure in Common Area "C" between lots 30 and 31, where offsite runoff (99 cfs) enters the site (D.S. 2-03.2.4.L.3).
11. Label Channel 1 and Channel 2 on the Tentative Plat.
12. Show the detention/retention basins dimensions and side slopes. Additionally, show the detention/retention basins ponding limits and water surface elevations (D.S. 2-03.2.4.L.1).
13. Show the water harvesting areas.
14. Show 1' (foot) no vehicular access easement along parcel boundary wherever it is needed as required by D.S. 2-03.2.4.F. and D.S. 3-01.6.1.H.
15. Detail B/5 should show filter fabric underneath the proposed riprap. Additionally, the proposed toe down should be revised to at least 3.78' depth according to the Drainage Report recommendation.
16. Due to the size of this project, it will require a Stormwater Pollution Prevention Plan (SWPPP). Submit a SWPPP with the Grading Plan submittal.
17. Work in the public right of way requires an excavation permit and may require a Private Improvement Agreement. Check with Transportation Department Permits and Codes for additional information.
18. Revise the Tentative Plat according to the Drainage Report revisions.

Landscape Plan:

1. Show water-harvesting basins.
2. Show sight visibility triangles to ensure that the proposed landscaping will not obstruct sight at street intersections.


Prepare a detailed response that explains the revisions that were made and references the exact location in the drainage report and on the Tentative Plat where the revisions were made.


RESUBMITTAL REQUIRED: Revised Tentative Plat, Drainage Report and Landscape Plan
02/24/2005 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: February 24, 2005


RE: Assessor’s Review and Comments Regarding Tentative Plat
S05-012 Liberty Village T151428 (136-15)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal. Please make the following additions/corrections in the final plat.
Remove the shading from the streets.
Add the interior bearings for the lot lines and add the dimensions and bearings for the street centerlines.
Add the complete curve data.
If there are any questions, please contact Susan King at 740-4391.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.






Susan King
02/24/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the plans to include additional vegetation in Common Area 'B' adjacent to Lakeside Parkway to meet the coverage requirements of LUC 3.7.2.4.A.5

2) Provide planting details for the vegetation proposed in Common Area 'C' where plantings are shown integrated in the 3:1 rip-rap slope.

RESUBMITTAL OF ALL PLANS IS REQUIRED.
02/28/2005 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: February 25, 2005

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks, Parks and Recreation

SUBJECT: CDRC Transmittal, S05-012 Liberty Village: Tentative Plat

CC: Craig Gross, Development Services


No comments.







Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov
03/01/2005 DALE KELCH COT NON-DSD TRAFFIC Denied Traffic Engineering REJECTS this TP:

1. A category I TIA will be required to be submitted and approved prior to approval of this TP.

2. Add access ramps to the following locations: corner at lot 64, between lots 50/51, 5/6, 16/17, 29/30

3. Remove the access ramps adjacent to lots 42, 46. There is no sidewalk across the roadway for anybody to go to at these locations.

4. The SVTs in detail D sheet 5/7 are sized incorrectly. Golf Links Road is an arterial roadway.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
03/02/2005 CRAIG GROSS COT NON-DSD REAL ESTATE Approved no objections.
03/03/2005 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL


TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera
Principal Planner

PROJECT:
Liberty Village RCP
S05-012
Tentative Plat

TRANSMITTAL: March 3, 2005
DUE DATE: February 28, 2005


1. An applicant has one (1) year from the date of application to obtain approval of a tentative plat that complies with zoning and other development requirements in effect at the time of application. This tentative plat must be approved on or before January 25, 2006.
LUC 4.1.7.1

2. Fill in the S05-012 number near the title block in the lower right hand corner of all sheets of the plat, landscape and NPPO plans.
DS 2-03.2.2.B.1

3. Golf Links Road is designated both as a Major Street and Route and a Gateway Route by the MS&R Plan. Add a general note which states that the project is designed to meet the overlay zone criteria of LUC Sec. 2.8.4, Gateway Corridor Zone, and LUC Sec. 2.8.3, Major Streets and Routes (MS&R) Setback Zone.
DS 2-03.2.2.B.7

4. For microfilming and archiving purposes the minimum type size must be 12 point (0.12"). Much of the dimensions and other print on the elevation drawings and floor plans (sheets 6 and 7 of the d.p.) do not meet this minimum requirement. Revise as necessary to meet standard.
DS 2-03.2.1.A.C

5. A copy of proposed CC&R's must be provided to the Zoning Review Section for review and approval prior to approval of the final plat. The CC&R's must meet the criteria of LUC 3.6.1.5 and DS 2-03.6.6.
DS 2-10.3.2.E

6. For setbacks purposes building heights are measured above design grade elevation rather than from finished floor elevation. For clarity in verifying building setbacks revise elevation drawings on sheets 6 and 7 to indicate the height of the exterior building wall above the ground or to indicate the difference between grade and floor elevations.
LUC 3.2.6.4

7. Due to proposed building heights being greater than 21 feet, revise all lot typical detail street setbacks (where not already specified) to indicate that the required street setbacks are the greater of 21 feet or height of exterior structure wall measured from edge of nearest travel lane. Provide additional lot typical information for lots 1 though 6 indicating that the required MS&R setback is the greater of 21 feet or height of exterior structure wall measured from back of future curb along Golf Links Road.
LUC 3.2.6.5

8. Revise plat to label and dimension future MS&R curbs (or add MS&R typical street cross section) for Golf Links Road and add existing and future sight visibility triangles to all intersections.
DS 2-03.2.4.M
DS 2-03.2.4.F

9. All requested revisions must be made to tentative plat, landscape & NPPO plans.
DS 2-07.2.1.A


If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
03/03/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed