Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S05-003
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/17/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 02/17/2005 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | February 22, 2005 To: Craig Hunt, P.E., Entranco, Inc. Thru: Craig Gross, CDRC Manager City of Tucson Development Services Department ____________________________________ From: Tim Rowe, P.E., (520-740-6563) representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: Civano North Ridge, Lots 1-79 And Common Areas A-C Tentative or Preliminary Plat - 1st Submittal S05-003 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Sheet 1: A portion of the proposed 30' landscape bufferyard shown along Houghton Road on Sheet 3 is also an existing 10' public sewer easement per Docket 10688, Page 841. This is permissible only if the landscaping within the public sewer easement conforms to PC/COT Standard Detail A-4. Replace General Note 34 (or, add a General Note) with one that states: THE LANDSCAPING WITHIN ALL PUBLIC SEWER EASEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4. Sheet 3: Delete the specific public sewer easement shown across Common Area C. All of Common Area C will need to be granted as a public utility easement by the final plat. Sheets 3 & 5: The vehicular access to Manholes 1 and 2 in Common Area C on Sheet 3 and the vehicular access to Manhole 23 on Sheet 5 was verbally approved by Mr. Eric Wieduwilt of PCWMD Operations, during the review of this project under subdivision plat case number, S02-051. No action is required on this item. This item is for information only. Sheet 4: Per verbal direction provided to me by Mr. Eric Wieduwilt, PCWMD's Chief Engineer, Manholes #12 and #15 may be eliminated from the design, if desired, as shown on sewer improvement plan, G-2004-066. A second 8" diameter sewer line coming into Manholes #11 and #14 at approximately 90 degrees is approved for this one project only. No change to the tentative plat is required by this item. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter. CC: Project File G-2004-066 |
| 02/24/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S05-003 Civano Northridge 02/24/05 (ü) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other CROSS REFERENCE: Civano Master Development Plan Civano Development Agreement Civano Impact System Memorandum of Understanding NEIGHBORHOOD PLAN: South Pantano Area Plan GATEWAY/SCENIC ROUTE: Houghton Road (Scenic Route) COMMENTS DUE BY: March 4, 2005 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached (ü) No Additional Comments - Complies With Planning Comments Submitted on: 02/02/05 ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: K. Aragonez 791-4505 DATE: 2/24/05 |
| 03/08/2005 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed | |
| 03/08/2005 | MICHAEL ST. PAUL | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Michael St.Paul FOR: Patricia Gehlen Planning Technician Principal Planner PROJECT: S05-003 Tentative Plat Conditional Approval TRANSMITTAL: March 8, 2005 DUE DATE: March 8, 2005 The Zoning Review Section at Development Services verifies that the tentative plat meets the requirements of the Land Use Code, subject to the following changes. However, should there be any changes requested by other CDRC members, the approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements. COMMENTS CODE SECTION/ DEVELOPMENT STANDARD 1. This conditional approval is dependent upon the approval of the Development Standards Modification Request (DSMR). Please provide the case number and date of the DSMR on the plate. Also provide on the plat the modifications granted and the conditions imposed. 2. The second condition for approval is the approval of the SCZ submittal. Should the CDRC recommend approval of the tentative plat, please have the applicant submit sign-off copies for approval. If you have any questions about this transmittal, please call Michael St.Paul, (520) 791-5608 x1184. |