Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S05-002
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S05-002
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/20/2005 FRODRIG2 PIMA COUNTY WASTEWATER Denied January 14, 2005

TO: John Evans, P.E., JAE Consulting Engineers

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: Vista Montaña Estates Phase Three, Lots 355-378 and Common Areas, A, C & D
- Submittal
S05-002 Final Plat


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Please be aware that this office will maintain its records for this plat under case number S03-029A, rather than S03-029, so that they will not be confused with the records for Vista Montaña, Lots 1-215 and Common Areas A-D. No action on JAE Consulting Engineer's part is required concerning this item other than being aware of this difference in the City's and the County's case numbers.

It is my understanding that an Approval Of Construction has not yet been obtained for the existing private sewers on the property. Be aware that such an approval (now typically called a Discharge Authorization) must be obtained for PDEQ's Subdivision Approval of this project. PDEQ's Subdivision Approval is necessary for your client to sell these lots.

Also, the Pima County Wastewater Management Department cannot execute any ADEQ Sewer Service Agreement form to serve these lots (which is necessary to obtain PDEQ's Subdivision Approval), authorize the construction of any model homes on these lots, or issue sewer connection permits for these lots, until this matter is resolved.

Please resolve the Approval of Construction issue with appropriate PDEQ staff at the earliest opportunity, and provide this office with a copy of the Discharge Authorization for the existing private sewer lines at the earliest opportunity. If this matter cannot be resolved with PDEQ, your client may need to build new private sewers to serve these lots. If so, the sooner the private sewer review process begins, the better it will be for your client.



Sheet 1: The public utility easements need to be granted to specific public entities, rather than the general public. Revise the wording of the 2nd paragraph of the Dedication to grant the public easements to PIMA COUNTY, THE CITY OF TUCSON AND ALL UTILITY COMPANIES . . .

Sheet 1: If your client plans on using the existing private sewers to provide sewer service to these lots, the public utility easements granted by this plat, will also need be called out as private sewer easements, and these private easements reserved by the Dedication. Revise the wording of the 1st sentence of the 3rd paragraph of the Dedication to read, PRIVATE STREETS, PRIVATE EASEMENTS, AND COMMON AREAS , . . .

(Note: I saw no drainageways, either public or private, on the plat, therefore I omitted DRAINAGEWAYS from the above language. If a public or private drainageway is to be created by this plat, the Dedication language may need further adjustment)

Sheet 1: If your client plans on using the existing private sewers to provide sewer service to these lots, add PRIVATE SEWERS to the list of homeowner association's responsibilities in the last sentence of the 3rd paragraph of the Dedication.

Sheet 2: Be more specific as to where the record of survey has been recorded in General Note 10. Is this Book and Page of Mesc. Recordings, or ?

Sheet 2 or 3: Show the public utility easement referenced in General Note 10. Label it as TO BE ABANDONED. Please note that other CDRC reviewers may require this easement to be abandoned by separate instrument, rather than by final plat.

Sheet 3: What does the dashed line approximately 10' feet from the easternmost subdivision property represent? Label it appropriately.

Sheet 3: Revise the keynotes referencing the easements to show whether the easements are existing or proposed. These keynotes should show whether these easements will be created BY THIS PLAT, or the recording information for the existing easements.

Sheet 3: The public utility easements adjacent to Common Area D, on Lots 365, 366, 367, 374, 375, and 376 should be 10' wide as shown on the approved tentative plat, and to match the 10' public utility easements on Lots 368-372.

Sheet 3: If your client plans on using the existing private sewers to provide sewer service to these lots, the public utility easements also must be designated as private sewer easements. Revise the keynotes as necessary.

Sheet 3: If your client plans on using the existing private sewers to provide sewer service to these lots, each cleanout in the private 6" and 8" sewers must be accessible by private sewer maintenance vehicles, which are typically pick-up or larger trucks. No passenger car or pick up truck is capable of making a 90 degree turn from one leg of 10' easement to another leg of the 10' easement.

If your client plans on using the existing private sewers to provide sewer service to these lots, the public utility and private sewer easements over the private sewer lines need be revised to accommodate the need for the sewer maintenance vehicles to turn from one leg of the easement to another. These easements will need to accommodate the minimum turning radii of the AASHTO P Design Vehicle (passenger car) at a minimum, and would preferably accommodate the minimum turn radii of the AASHTO SU Design Vehicle (single unit truck).

A Sewer Service Agreement between the owner of record and PCWMD will need to be executed. This office will prepare this agreement after it knows more about whether the existing private sewers will be utilized, or whether new private sewers will be built.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

County Ordinance 2003-29 went into effect on April 11, 2003. This ordinance requires that a wastewater review fee be paid for each submittal of the final plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $100.00 (made out to PIMA COUNTY TREASURER ) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.

Copy: Project
01/21/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S05-002 VISTA MONTANA ESTATES III/FINAL PLAT
DATE: 1/14/05



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Fill in all books and pages before recording.

2.) Change the east half of the Southwest ¼ to the west half on all Title Blocks.
01/24/2005 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, 01/24/2005, Engineering and Floodplain Review.


SUBJECT: Vista Montana Estates
S05-002, T15S, R15E, SECTION 19

RECEIVED: Final Plat and CC & R's on January 07, 2005

The subject project has been reviewed. The Final Plat and the CC & R's are recommended for approval pertaining to Engineering and Floodplain. Submit the Final Plat Mylar for processing.
01/27/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: VISTA MONTANA ESTATES III
Lots 355-378
S05-002

The Final Plat for the subject project will meet this Company's easement
requirements.
Please forward any resubmittals of the final plat to this office.

Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8745
Cell Phone: (520) 904-2668
Fax: (520) 917-8700
02/01/2005 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: February 1, 2005


RE: Assessor’s Review and Comments Regarding Final Plat
S05-002 Vista Montana Estates Phase III T151519 (141-09)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.







Susan King
02/08/2005 FRODRIG2 COT NON-DSD REAL ESTATE Approved No objection
02/10/2005 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: S04-002
Vista Montana Estates III, Lots 355 - 378 and Common Areas "A", "C", "D"
Final Plat

TRANSMITTAL: 02/10/05

DUE DATE: 2/7/2005

COMMENTS:

1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before January 6, 2006.

2. This final plat submittal has been assigned the subdivision case number S05-002. Please list the assigned case number on all plan sheets. List the case number S03-029 as a reference case number. DS 2-03.6.1.K

3. Please relocate the RECORDING text block under the APPROVAL text block. DS 2-03.6.3.D

4. List in the title block that this subdivision is a Residential Cluster Project.

5. List the in the title of the CC&R's the lot numbers and common areas in the Phase III development. Also please clarify if a separate homeowner's association is proposed for Phase III or will the annexation of the Phase III development be inclusive of the existing CC&R's and neighborhood association. Per the CC&R's document submitted for review, under the Declarations section two, "there shall be no neighborhood association the Phase II property", please clarify.

If the Phase III property is annexed by Phase I and II will the recorded CC&R's for those phases be in force for Phase III? In addition if there will be not neighborhood association and the Phase II parcel is not annexed by the other phases who ill be responsible for the Common Areas in phase III. Keep in mind that all RCP development requires CC&R's for the development and neighborhood associations enforce all CC&R regulations.

Submit a copy of the recorded CC&R's if the Phase III property is to be annexed by the other phased developments. Thank you.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\finalplat\S05002fp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat, CC&R's and additional requested documents.
02/14/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed