Plan Number: S04-190
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S04-190
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2006 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: David Rivera
Principal Planner

PROJECT: S04-190
Vactor Ranch, 108-126, and Common Area "A"
Tentative Plat - Residential Cluster Project

TRANSMITTAL: January 7, 2006

DUE DATE: December 21, 2005

COMMENTS:

1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is December 22, 2005.

This tentative plat has expired and must be re-reviewed for additional code requirements that may be applicable unless an extension of the tentative plat approval date has been granted by the Planning Administrator, Craig Gross. Please contact Craig and request the extension. The review on the revised tentative plat has been done under the assumption that the extension has been granted and based solely on the previous comments made by the zoning review section reviewer.

2. The required items per rezoning condition 10 that were to be submitted to CDRC for review could not be found in the zoning package. Please confirm if these items were provided for the zoning reviewer if not please provide the required documents with the next submittal.

Previous Comment left as reference for reviewier: Please submit, a separate response letter that that lists or demonstrates how all the rezoning conditions have been met. The response letter should be specific to each rezoning condition even if several of the conditions have been met as a result of the previous Phase of Vactor Ranch. DS 2-03.2.2.B.3

3. Please confirm approximately, the time frame for abandonment of the easements in question order to determine the method of approval for the tentative plat by the zoning review section.

All existing easements that are to be abandoned must be abandoned prior to approval of the tentative plat. The recordation data of each existing easement to be abandoned must be listed on the tentative plat.

Previous Comment: All proposed or existing easements must be drawn and labeled on the plat. The location, purpose, width and recordation information of existing easements must be labeled on the plan. DS 2-03.2.3.C. and DS 2-03.2.4.J

4. There appears to be a discrepancy between the cross section 2/3 and the street dimensions on the plan view drawing. The cross section depicts a 32-foot wide roadway that includes the 2-foot wedge curbs on both sides of the street. The plan view drawing depicts a 30-foot roadway that includes the 2-foot wedge curbs on both sides of the street. Please clarify the discrepancy and revise as required. Also please clarify that on street parking is adjacent to the perimeter of the new subdivision. Label the parking lane on the plan view drawing. If the parking is not along the new subdivision boundary a DSMR will be required for the parking requirement. (It is acknowledged that the existing homeowners association had issues with on parking along both Valley Ranch Trail and Vuelta Rancho Mesquite.)

Previous Comment: Cross-section 2/3 must include reference to the width of the Common Areas as approved per the previous plat. Also clarify if the cross section applies to Vuelta Rancho Mesquite roadway. If so list the street name under the cross section detail.

The previous two comments have been left as reference for the reviewer's information.

This comment has not been fully addressed. Visitor parking must be provided for the entire subdivision as proposed. Lots 119 through 126 do not appear to be within 150 feet of the parking spaces provided in the new interior street. Per cross-section 2/3 on street visitor parking or parking lanes are not allowed on either side of Vactor Ranch or Vuelta Rancho Mesquite roadways. How will the visitor parking be provided for these units. Additional comments may be forthcoming and possibly an application for approval/support by the CDRC committee for development standard modification request for this development standard may be required prior to approval of the tentative plat.

Previous Comment: Parking on both sides of the street is required. Draw a cross section that depicts the construction and dimensions of the proposed street. Also the existing streets on which the boundary lots have frontage must be designed to provide on street parking. On street parking spaces must be provided within 150 feet of the property lines of the proposed boundary lots. The distance is not determined as the crow flies. It is determined based on the route necessary to get to from the parking spaces to the lots. Draw the requested detail drawings for the street cross section and depict the parking spaces based on an 8'x23 parking space. DS 2-03.2.3.G

5. Previous comment was not addressed. Address as requested.

Depict and label the perimeter boundary building setback based on the adjacent zoning and the street perimeter building setbacks. The street perimeter building setbacks from the existing street is to be based on the greatest of 21 feet or the height of the structure.

Draw lot typical detail drawings for an interior lot and for a corner lot and depict and label the interior and street building setbacks inclusive of the principal structure and garage. List the proposed building heights of the structures. DS 2-10.3.1.A. and .B

8. Address the following items under the RCP data text block. DS 2-10.3.1.A - .D

a. The allowed lot coverage under the RCP designator RCP-9 is 75%. Please revise the coverage note under the RCP data text block. Previous comment: Revise the site coverage calculations based on the correct RCP designator.

b. Because this subdivision is a continuation of or final phase of the previously approved Vactor Ranch subdivision the building setbacks may be 3' from the property line for all new lots abutting the existing Vactor Ranch subdivision. Remove or revise the note listing the rear building setback of 10-foot or ¾ hgt of the structure.
The front street building setback for lots 110 through 116 may be based on the allowed building setback as listed in LUC section 3.2.6.5. The ADT of the interior street is less than 140.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\tentativeplat\S04190tp3.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat and additional requested documents
01/09/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

January 9, 2006

Paul Nzomo
Coronado Engineering
1010 N. Finance Center Dr, #200
Tucson, AZ 85710

Subject: S04-190 Vactor Ranch Tentative Plat

Dear Paul:

Your submittal of December 8, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

5 Copies Revised Tentative Plat (zoning, engineering, landscaping, wastewater, DSD)

4 Copies Revised Landscape Plan (zoning, landscaping, engineering, DSD)

2 Copies Revised NPPO (landscaping, DSD)


The review period of this tentative plat has expired. An extension letter must be submitted and accepted prior to resubmittal of these plans.

Should you have any questions, please call me at 791-5608.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 571-1961
12/07/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
12/13/2005 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: December 13, 2005
CDRC/Zoning Manager

SUBJECT: Vactor Ranch, 7300 E. Vactor Ranch Trail
Tentative Plat S04-190 (Third Review)
T13S, R15E, Section 32

RESUBMITTAL REQUIRED: Tentative Plat.

The Tentative Plat (TP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Tentative Plat:

1. Please include a response letter to the comments along with the corrected copies of the TP.
2. Show the proposed pad grades for each lot. Requested pad grades have resulted in the following comment:
3. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please address.


Drainage Report:
1. The DR has been accepted conditionally for tentative plat purposes. The following comments must be addressed prior to the acceptance of the DR and the issuance for the grading permit.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@ci.tucsonaz.govs
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/7300 E. Vactor Ranch CDRC 3
12/21/2005 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond 1) Revise the plans such that all lettering and dimensions shall be the equivalent of twelve (0.12") point or greater in size. DS 2-05.2.1.C

2) The landscape plans show trees numbered 600-604 between the proposed sidewalk and the curb, but the aerial photo appears to show the trees farther from the curb. It is important to precisely locate the existing trees on the landscape plan. Based on the actual locations it may be necessary consider alternative sidewalk design. Revise the plans as necessary.

3) Revise the native plant preservation plan to show the limits of grading. DS 2-15.3.4.A
Delineate the actual preservation fence locations
DS 2-15.6.0

4) An irrigation plan for all of the landscape installations is required. We have received only a partial plan. Development Standard 2-06.5.4.A and 2-06.5.4.B.

5) In order to designate protected trees as preserved in place a Plant Nondisturbance Area is required per LUC 3.8.6.7.C. All plants designated by the approved Native Plant Preservation Plan to be preserved-in-place shall be retained at their existing grade during and after construction for a distance as outlined in Development Standard 2-15.6.0. The distance per the development standard is 1.5 times the drip-line radius. Plants 600-604 appear to be located in an area where sidewalk construction is to occur and some of the tree canopies extend over areas on lots where construction is proposed. The plans must address specifically how the root zone and the tree branches will be protected. Revise the plans as necessary.

6) The landscape and native plant preservation plans when approved will be archived in black and white. Revise the documents to insure that symbols and other plan features will be distinguishable upon reproduction in black and white.

7) Revise the landscape and native plant preservation plans to locate trees 590, 598, and 599 consistently. The same trees are shown in different locations.
12/23/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S04-190 Vactor Ranch 12/22/05

(x) Tentative Plat
() Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-96-01

NEIGHBORHOOD PLAN: Sabino Canyon - Tanque Verde N.P.

GATEWAY/SCENIC ROUTE: N/A

COMMENTS DUE BY: 12/21/05

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
(XXXX) No Additional Comments - Complies With Planning Comments Submitted on: 7/6/05
() Tentative Plat
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: D. Estolano 791-4505 DATE: 12/20/05
12/29/2005 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approv-Cond December 29, 2005

TO: Paul Nzomo, P.E.
Coronado Engineering & Development, Inc.

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: R S Engineering (Contract Reviewer)
Subhash Raval, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Vactor Ranch, Lots 108-126 and Common Area A
Tentative Plat - 3rd Submittal
S04-190

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

1. Install a new manhole, north of existing manhole 6876-16. Connect to proposed manhole 1 from this new location in order to avoid the acute angle created by S-1 and S-3.

2. Subject to the above required revisions, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat/final plat/development plan.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution




If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Subhash Raval, P.E.
Telephone: (520) 740-6586

Copy: Project