Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S04-188
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S04-188
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/15/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/05/2006 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approv-Cond September 1, 2006

TO: Steven Hill, P.E.
Leadstar Engineering

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Chandubhai C. Patel, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Silverbell Crossings, Lots 1-143 and Common Areas A-D
Tentative Plat - 6th Submittal
S04-188

Your submittal received by us on August 11, 2006 for the proposed sewer collection lines to serve the above-referenced project has been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

1. I understand that the request for sewer easement across the Silverbell Golf Course has been conditionally approved by the City of Tucson .The PCWMD and the Real Property Division are working together to meet the conditions of this approval

2. SHEET 8 & 9 Show the existing sewer lines and manholes using the same line types as shown in the legend, i.e., use lighter dashed lines.
.
3. The Pima County Department of Environmental Quality and the Wastewater Management Department hereby approve the above referenced submittal of the Tentative Plat SUBJECT TO THE ABOVE COMMENT. The corrections can be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize
the construction of public or private sewer lines or water distribution lines. Prior to the
construction of such features, a Construction Authorization (Approval To Construct) may
need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the
Pima County Department of Environmental Quality prior to constructing, operating or engaging
in an activity which may cause or contribute to air pollution.

If you have any question regarding the above comments , please do not hesitate to contact me.

Sincerely,



Chandubhai C. Patel, P.E
Phone: 520-740-6563

Copy: Project File.
09/15/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-188 SILVERBELL CROSSING/REVISED TENTATIVE PLAT
DATE: September 12, 2006’



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
















jg
09/19/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approved COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 19, 2006

Steve Hill
Leadstar Engineering
10101 Finance Center Drive
Tucson, Arizona 85710

Subject: S04-188 Silverbell Crossing Tentative Plat

Dear Steve:

The above referenced development plan/tentative plat has been APPROVED by the Community Design Review Committee. Please submit the following documents for sign-off.

1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan/Tentative Plat, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal).
AND
1 Double Matte right-reading Océ or Photo Mylar of the Development Plan/Tentative Plat.

The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

PIMA COUNTY WASTEWATER HAS VERIFIED THAT MYLARS MEET CONDITIONS OF APPROVAL.

Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 571-1961