Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S04-181
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/23/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/30/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Craig Gross DATE: June 30, 2005 Planning Administrator SUBJECT: 687 S. Bonanza Ave., Desert Enclave Final Plat S05-181 (First Review) T14S, R15E, Section 14 RESUBMITTAL REQUIRED: Final Plat. The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Final Plat: 1. Please provide North arrow and scale per D.S. 2-02.2.1. 2. Please include a response letter to the comments along with the corrected copies of the FP. 3. Submit the Subdivision Improvement Assurances for review. 4. The title block of the plat must match the Subdivision Assurances verbatim. 5. Show the symbol on the legend for the standard monument detail 103 on the centerline of the proposed streets per D.S. 2-03.6.5.6. 6. Please re-label all common areas that may be used in a dual and/or single use capacity per D.S. 2-03.6.4.C. For example, a Ret./Det. Basin may also be used as a recreation facility or only as a drainage facility or drainage channel and this must be reflected on the Final Plat. A key note explaining the labels could be used in conjunction with the labels, ie.: Common Area "A" - Streets Common Area "B" - Drainage/Recreation Facilities Common Area "C" - Recreation Facilities Common Area "D" - Drainage Facilities Common Area "E" - Landscaping 7. Show sight visibility triangles per D.S. 2-02.2.1.10. 8. Correct the mile of new public street on general note 3 per D.S. 2-03.6.2.C. 9. Show the "Certification of Survey" verbatim per D.S. 2-03.6.3.A. 10. Show a 1' no access esmt. along the west property line of lots 13 and 14 and the Common Area "C" between the two lots. 11. Please submit a copy of the subdivision boundary closure calculations. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/687 S. Bonanza Ave. FP |
| 07/07/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S04-181 DESERT ENCLAVE/FINAL PLAT DATE: 7/06/05 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Delete Desert Enclave Drive adjacent to lots 13 & 14. Karst (change the suffix to Place or Court) can be adjacent to lots 8-13 and Caldera (change the suffix to Place or Court) can be adjacent to lots 14-19. es |
| 07/25/2005 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | No objection |
| 07/25/2005 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | July 25, 2005 TO: Greg Carlson, P.E. Greg Carlson Engineering, LLC THRU: Patricia Gehlen City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Desert Enclave, Lots 1-28 and Common Areas A-C Final Plat – 1st Submittal S04-181 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. A public Sewer Service Agreement for the proposed number of residential lots has been sent to your office. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals should be returned to Pima County Wastewater Management in order to satisfy the necessary requirements needed to approve the Mylars of the final plat. SHEET 1. Add the following two General Notes THE LANDSCAPING WITHIN ALL PUBLIC SEWER EASEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4. NO PERMANENT STRUCTURES (I.E., MASONRY WALLS, FENCES, ETC.) MAY BE CONSTRUCTED ON OR THROUGH THE PUBLIC SEWER EASEMENTS SHOWN HEREON WITHOUT SEPARATE WRITTEN CONSENT OF THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT. The signed copy of the tentative plat for this project requires certain information that was shown on its last submittal prior to approval. Please revise the following: Sheet 2. Show the southern border of the existing public sewer easement. Sheet 4. Show the invert elevations for all newly proposed manholes. Sheet 4. Show the southern border of the existing public sewer easement. Sheet 4. Two newly proposed manhole 2s are shown. Revise the layout to show one newly proposed manhole 2 and one newly proposed manhole 1. Upon completing these revisions, please resubmit a signed copy of the tentative plat. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 07/27/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Peter McLaughlin Senior Planner FOR: David Rivera Principal Planner PROJECT: Desert Enclave S04-181 Final Plat TRANSMITTAL: July 27, 2005 DUE DATE: July 25, 2005 1. Remove the linear footage from general note 3 as it is not correct and does not correspond to the distance shown in miles. DS 2-03.6.2.C If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 08/09/2005 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: DESERT ENCLAVE Lots 1-28 S04-181 Tucson Electric Power Company (TEP) has received the final plat submitted for review June 24, 2005. This Company is unable to approve the plat at this time. TEP is in the process of completing the preliminary electrical design to determine our easement requirements. The design should be completed approximately August 9, 2005. The designer for the project is Frank Grijalva he can be reached at (520) 918-8361. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 08/10/2005 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) Sahuarita, Az. 85629 FROM: Ed Abrigo, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: July 22, 2005 RE: Assessor’s Review and Comments Regarding Final Plat S04-181 Desert Enclave T141514 (133-39) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * x Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Jessica Shettleroe |
| 08/11/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 11, 2005 Greg Carlson, P.E. Greg Carlson Engineering, LLC 1521 East Broadway Blvd. Tucson, AZ 85719 Subject: S04-181 Desert Enclave Final Plat Dear Greg: Your submittal of June 24, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 6 Copies Revised Final Plat (addressing, wastewater, TEP, engineering, zoning, DSD) ASSURANCES TO BE SUBMITTED TO THE CDRC OFFICE Should you have any questions, please call me at 791-5608. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 624-4197 |