Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S04-179
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S04-179
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/17/2005 FRODRIG2 COT NON-DSD REAL ESTATE Approved No objection
06/27/2005 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-179 EMPIRE HEIGHTS/FINAL PLAT
DATE: JUNE 27, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1.) Label Minoan Drive on pgs. 1, 4 & 5.



















jg
06/27/2005 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-179 EMPIRE HEIGHTS / REVISED FINAL PLAT
DATE: JULY 20, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

Approved with the following condition

1: Label Minoan Drive on pgs. 1, 4 & 5 (on recorded mylar)


***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***












sg
06/28/2005 PAUL MACHADO ENGINEERING REVIEW Denied To: James Dean, P.L.S. DATE: June 28 2005
E.E.C., Inc.
4625 E. Ft. Lowell Rd.
Tucson, Arizona 85712

SUBJECT: Empire Heights, 10500 E. Jumping Cholla Drive
Final Plat S04-179 (First Review)
T15S, R15E, Section 25

RESUBMITTAL REQUIRED: Final plat.

The Final plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please include a response letter to the comments along with the corrected copies with re-submittal.
2. Please submit a copy of the subdivision boundary closure calculations.
3. Submit the Subdivision Improvement Assurances per D.S. 1-04.4.1.
4. The subdivision title, on the plat, shall match the Subdivision Improvement Assurance verbatim.
5. Show the SVT's on the plat.
6. Move the name below the signature line of the "Recording" paragraph. Confirm with the recorder's office which to title to use for the recorder's name.
7. Remove the 1' ACE at the trail easement ends or rename the 1' ACE to include "vehicular".
8. Label and dimension the easement shown on plat adjacent to lot 66.
9. The line type for the 10' PUE on sheet 5 lists as "100-year floodplain" on the legend.
10. Show only the symbols used on the legend.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/10500 E. Jumping Cholla Drive FP
07/11/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: EMPIRE HEIGHTS
Lots 1-241
S04-179

Tucson Electric Power Company (TEP) has reviewed the final plat submitted
for review June 14, 2005. TEP is unable to approve the plat at this time.

In order for TEP to approve the final plat, the following will be required.

* Delete the word FOR from the third paragraph of the dedication to
read as: "WE HEREBY GRANT TO THE PUBLIC AND ALL UTILITY COMPANIES ALL
EASEMENTS AS SHOWN HEREON FOR THE PURPOSES OF ACCESS, INSTALLATION AND
MAINTENANCE OF PUBLIC SEWERS......... etc.
* Dedicate a specific 15' wide TEP easement or Public Utility Easement
for the three phase underground extension along the northern boundary and
eastern boundary within the Common Area. In the future TEP may need to feed
adjacent properties out of this equipment and a specific easement will be
necessary.

Show the requested change to the dedication and the required easement on the
resubmittal of the final plat. Submit two bluelines to the City of Tucson
for TEP's final approval.

Please contact me at (520) 917-8745 if you have any questions.

Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
07/14/2005 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: July 13, 2005


RE: Assessor’s Review and Comments Regarding Final Plat
S04-179 Empire Heights T151525 (141-17)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: BEFORE RECORDING THIS PLAT PLEASE MAKE THE FOLLOWING ADJUSTMENT:
IDENTIFY THE AREA BETWEEN LOTS 134 AND 135 ON SHEET 3 OF 5.
THANK YOU FOR YOUR SUBMITTAL.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.





ROSANNA WERNER
07/20/2005 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond July 19, 2005

TO: Joe Zeman
EEC

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Empire Heights, Lots 1-241 and Common Areas A & B
Final Plat – 1st Submittal
S04-179


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


A public Sewer Service Agreement for the proposed number of residential lots has been sent to your office. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals should be returned to Pima County Wastewater Management in order to satisfy the necessary requirements needed to approve the Mylars of the final plat.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.



If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
07/26/2005 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: S04-179
Empire Heights Lots 1-241 and Common Areas "A" and "B"
Final Plat

TRANSMITTAL: 07/26/05

DUE DATE: July 13, 2005

COMMENTS:

1. The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

2. On sheet one please label all common areas. DS 2-03.6.4.C

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

C\planning\cdrc\finaplat\S04179fpca
07/28/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

August 2 2005

Joe Zeman
EEC
4625 East Fort Lowell Road
Tucson, AZ 85712

Subject: S04-179 Empire Heights Final Plat

Dear Joe:

Your submittal of June 14, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

4 Copies Revised Final Plat (TEP, engineering, zoning, DSD)



ASSURANCES TO BE SUBMITTED TO THE CDRC OFFICE

Should you have any questions, please call me at 791-5608.

Sincerely,


Patricia Y. Gehlen
CDRC Manager





All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 321-0333