Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S04-179
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/15/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 02/16/2005 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 02/18/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S04-179 EMPIRE HEIGHTS/REVISED TENTATIVE PLAT DATE: February 18, 2005 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Change Ottis Drive to Otis Drive on pgs. 2 & 4. Correct lot numbers of Richmond American Homes on pg. 2. Label Minoan Drive on pg. 3. Page divisions on pg. 1 do not match pages. Label all corner lots with a star symbol the location of access on Final Plat. jg |
| 02/22/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S04-179 Empire Heights 02/22/05 (x) Tentative Plat () Development Plan (x) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: Houghton Area Master Plan NEIGHBORHOOD PLAN: Esmond Station Area Plan GATEWAY/SCENIC ROUTE: N/A COMMENTS DUE BY: March 02, 2005 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached (x) No Additional Comments - Complies With Planning Comments Submitted on: 12/29/04 ( ) Resubmittal Required: ( ) Tentative Plat () Development Plan ( ) Landscape Plan () Other REVIEWER: E. Anderson 791-4505 DATE: 02/22/05 |
| 02/28/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 03/02/2005 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | The Tentative Plat is approved February 16, 2005. |
| 03/02/2005 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this TP. D. Dale Kelch, EIT Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 03/07/2005 | DAVID RIVERA | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: S04-179 Empire Heights Lots 1-241 and Common Areas "A" and "B" Tentative Plat TRANSMITTAL: 03/07/05 DUE DATE: 03/2/2005 COMMENTS: 1. The Zoning Review Section verifies that the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. C:\planning\cdrc\tentativeplat\S04179tpa.doc |
| 03/08/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Craig Gross DATE: March 8, 2005 Planning Administrator SUBJECT: Empire Heights Tentative Plat S04-179 (Second Review) T15S, R15E, Section 25 RESUBMITTAL REQUIRED: Tentative Plat. The Tentative Plat (TP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Tentative Plat: 1. Please include a response letter to the comments along with the corrected copies of the TP. 2. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please address. The lots on the Western edge of the subdivision are affected by the 2' grading differential, review and adjust the pad as necessary. As mentioned in the comment responses, the 2' grading differential caused by erosion cannot be taken into consideration. 3. The R/W width for Cholla Jumping Drive must be matched in width from the existing R/W on the recorded plat on Richman American Homes at Rita Ranch, Bk. 53, Pg. 92. Why was a 60' R/W used for the width of Jumping Cholla Dr.? Provide documentation from COT Transportation for allowing the difference between the two R/W's. 4. Provide a note on the TP indicating that the channel to the west will be improved at the grading plan stage. Drainage Report: 1. The DR has been accepted for TP plat purposes only. The final acceptance will be done at the grading plan stage. 2. I spoke with Laith Alshami and it was agreed that either an excerpt of the Master Drainage Report be included in the DR to show compliance or the statement in the DR that you have reviewed and agree with the data from the Master Drainage Report for Rita Ranch would be required. 3. Please add a statement in the DR indicating that Rick Engineering and the Homeowners Association are working on the ultimate solution or to that effect. 4. Show the project address on the cover of the DR. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@ci.tucsonaz.govs Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/Empire Heights TP 3 |
| 03/08/2005 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed |