Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S04-152
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/13/2005 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 04/22/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S04-152 Desert Stones 04/22/05 (x) Tentative Plat () Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: C9-04-10 NEIGHBORHOOD PLAN: Rincon/Southeast Subregional Plan GATEWAY/SCENIC ROUTE: N/A COMMENTS DUE BY: 04/27/05 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached (x) No Additional Comments - Complies With Planning Comments Submitted on: 02/15/05 ( ) Resubmittal Required: ( ) Tentative Plat () Development Plan ( ) Landscape Plan () Other REVIEWER: Eric Anderson 791-4505 DATE: 04/18/05 |
| 04/25/2005 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approved | Laith Alshami, Engineering and Floodplain Review, 04/27/2005 SUBJECT: Desert Stones S04-152, T15S, R15E, SECTION 19 RECEIVED: Tentative Plat, Landscape Plan and Drainage Report on April 13, 2005 The subject submittal has been reviewed. The Drainage Report is acceptable for tentative plat purposes. Additional drainage related information might be required with the Grading Plan. The Tentative Plat is acceptable and it is recommended for approval pertaining to Engineering and Floodplain Review. It appears that the proposed landscaping in the detention/retention basins will be in conflict with the maintenance access ramps and Basin #2 weir outlet. Show the access ramps on the landscape plan and correct any conflicts. |
| 04/27/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Revise sheet 7 of the landscape plan to show the drainage easement. Modify the lines that indicate a property boundary, where none is located. 2) Clarify who will accept maintenance responsibilities for the landscaping west of Wilmot Road. The native seed mix should be utilized in this area. 3) Resubmittal of the native plant preservation plan is required. No copy was received for this review. 4) Revise the native plant preservation and landscape plans to clarify the limits of grading/disturbance for improvements west of Wilmot Road. 5) Add the following note to the landscape plans. "City Engineer approval of plan and permit applications is required for excavation, landscaping and irrigation within public right of way areas". 6) Remove the "grass" call out on sheet 2 of the landscape plan at lots 163 and 164. Resubmittal of all plans is required. |
| 04/28/2005 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed |