Review Details: RESUBMITTAL- OTHER SUBDIVISION REVIEW
Plan Number - S04-148
Review Name: RESUBMITTAL- OTHER SUBDIVISION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/29/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Storm water detention/retention basins not integrated with paved vehicular use areas shall be landscaped to enhance the natural configuration of the basin per LUC 3.7.4.3.A Design criteria are set forth in Development Standard 10-01.0. The Land Use Code does not allow for single-purpose basins (see response letter from ADG), except for those that utilize paved parking areas. The requirement to landscape to enhance the natural configuration assumes aesthetic landscape treatments and a natural design. DS 10-01.4, p. 77-78 provides the requirements for the basin side slopes. Revise as necessary to comply with the requirement. 2) Provide calculations for the vegetative coverage of the retention basin. The minimum coverage is 35%. |
| 08/30/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S04-148 BONILLAS PARKWAY / REVISED OTHER SUBDIVISION REVIEW DATE: August 30, 2005 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. Recorded deeds with legal descriptions are required in order to assign addresses. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through the Pima County Subdivision Coordinator. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 08/31/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 09/13/2005 | JIM VOGELSBERG | ENGINEERING | REVIEW | Denied | DATE: September 13, 2005 TO: Patricia Gehlen; CDRC Coordinator SUBJECT: Bonillas Parkway Minor Subdivision Final Plat 2nd Submittal Engineering Review LOCATION: T15S R14E Section 7 REVIEWER: Jim Vogelsberg ACTIVITY NUMBER: S04-148 SUMMARY: The revised Minor Subdivision Final Plat, revised Drainage Report, Geotechnical Report, and response letters, were received by Engineering on August 29, 2005. See separate comment letter for the assurances review. Engineering has reviewed the received items and recommends conditional approval of the Final Plat. The Drainage Report was reviewed for Final Plat purposes only. FINAL PLAT CONDITIONS OF APPROVAL: 1) DS Sec.2-03.6.3.B: The dedication portion of the cover sheet shall be corrected to show Arizona Corporation per discussions with the project engineer. 2) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. Assurances must be approved by time of Final Plat mylar approval. See comments on separate comment letter. Submit revised Final Plat (mylar or bond), revised assurances, and detailed response letter. Call me at 791-5550, extension 2204, to discuss assurances comments or plat conditions or to schedule a meeting. Elizabeth Eberbach, PE For Jim Vogelsberg, PE Engineering Division Development Services |
| 09/22/2005 | PATRICIA GEHLEN | ZONING-RECORDATION | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 22, 2005 Kent Delph Delph Engineering 221 N. Court Ave Tucson, AZ 85701 Subject: S04-148 Bonillas Parkway Plat Dear Kent: Your submittal of August 29, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 3 Copies Revised Plat (engineering, landscaping, DSD) 3 Copies Revised Landscape Plan (engineering, landscaping, DSD) ASSURANCES TO BE SUBMITTED TO THE CDRC OFFICE Should you have any questions, please call me at 791-5608. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 882-6570 |
| 09/30/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 22, 2005 Kent Delph Delph Engineering 221 N. Court Ave Tucson, AZ 85701 Subject: S04-148 Bonillas Parkway Plat Dear Kent: Your submittal of August 29, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 3 Copies Revised Plat (engineering, landscaping, DSD) 3 Copies Revised Landscape Plan (engineering, landscaping, DSD) ASSURANCES TO BE SUBMITTED TO THE CDRC OFFICE Should you have any questions, please call me at 791-5608. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 882-6570 |