Plan Number: S04-148
Parcel: Unknown

Address:
5901 S PARK AV

Review Status: Completed

Review Details: RESUBMITTAL- OTHER SUBDIVISION REVIEW

Plan Number - S04-148
Review Name: RESUBMITTAL- OTHER SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
05/06/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-148 BONILLAS PARKWAY/REVISED MINOR SUBDIVISION REVIEW
DATE: 5/05/05



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Change Los Montanas to Las Montanas on site Location Map.

Change Los Ranchitos 5 Bk 8, Pg 41 to Bk 7, Pg 96 on site Location Map.

Change resubdivision information to read “a portion of Lot 250” on all Title Blocks.

Change all Los Ranchitos Number 6 Bk 8, Pg 48 to Pg 41.
05/12/2005 PETER MCLAUGHLIN ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera
Principal Planner

PROJECT:
Bonillas Parkway
S04-148
Final Plat

TRANSMITTAL: May 12, 2005
DUE DATE: May 18, 2005

COMMENTS: The Zoning Review Section at the Development Services Department approves the final plat for this subdivision, subject to the following change on the executed final plat. However, should there be any changes requested by other CDRC members, the approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

Should the CDRC recommend approval of the final plat, please have the applicant submit the executed final plat for signature, and a memo stating that the members of the CDRC have approved the final plat. When these items are received, along with forty-four half-sized prints of the final plat, the final plat will be scheduled for consideration at the next available Mayor and Council meeting.


1. Correct the case number in the lower right hand corner of sheets 1 of 3, 2 of 3, and 3 of 3 to read S04-148. DS 2-03.6.1.K

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
05/17/2005 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this plat.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
05/18/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise all plans to meet the basin slope/depth requirements of DS 10-01.09, p. 78. Basins with depths greater than three feet are limited to 4:1 side slopes.

2) Revise the landscape plan to provide a minimum of 35% vegetative coverage for the retention basin. DS 10-01.4, p.89.

RESUBMITTAL OF ALL PLANS IS REQUIRED.
05/20/2005 DOUG WILLIAMS ENGINEERING REVIEW Denied TO: Craig Gross
SUBJECT: Bonillas Parkway
REVIEWER: Doug Williams
DATE: 25 May 2005
CDRC Case # S04-148
T15S, R14E, Sec. 7

Resubmittals required: Revised Final Plat, Revised Drainage Report and a Soils Report.

SUMMARY: Engineering Division has reviewed the revised Final Plat, Drainage Report, Landscape plan, and Concept Grading Plan. The following comments must be addressed on a revised plat and revised drainage report:

1. Please include a description of the corner marker tie (1/16 corner?) on the plat DS 2-03.6.5 A.
2. Please include/specify that the future right of way is to be dedicated "BY THIS PLAT", per the City's Major Streets and Routes Plan (DS 2-03.6.4 A & DS 2-03.2.4 H).
3. Please revise the TEP, NVA, and any other easement lines to match the dashed line provided in the legend (DS 2-03.6.5 B).
4. Please indicate ½" iron rods will be set at ALL corners upon completion of construction, e.g. Common Area B, and the western lot line of Lot 1intersection with the Common Area A.
5. (DS 2-03.6.5 C 4 B).
6. Specify in the Title Block description that this project is a resubdivision of a PORTION of Lot 250 (DS 2-03.2.1 G 3).
7. Omit reference to Lot 249 east of the subject property, and label this area as a portion of (the original) Lot 250 (continuing 100' to the east - see title report). The parcel number may be included.
8. Correct all references to reflect the correct Book and Page of Los Ranchitos Subdivision. (Bk 8/ Pg 41).
9. Please verify the "PLATTED LOT LINE" 10' west of the subdivision boundary, and specify recording information.
10. Specify the title company name and description (such "an Arizona corporation…") and trust number in item 3 of the DEDICATION paragraph.
11. Please assure the proper (2") margin is provided on the right hand side of the plat.
12. Please address and depict the easements described in the title report (items 7 & 8), on the plat.
13. The right of way dedication for Park Ave. must include a minimum 25' spandrel. Please revise the plat as necessary (DS 2-03.6.4 A & DS 2-03.2.4 H).
14. Correct the CDRC case # (S04-148).
15. Re-check the Park Ave. existing Right of Way dimension (dimensioned at 30', scales to 40'), and provide Alvord Rd. Right of Way dimension (Previous comment #14).

DRAINAGE REPORT:

16. Provide a topographic map (or photo-topo, preferably) at a scale of 1"=200' or larger, and re-check/revise the offsite water delineation that may affect the project or adjacent Right of Way. Particular attention should be given to the divide depicted at the intersection of Mossman Rd. and Randall Blvd. Revise the text and any subsequent calculations as necessary (previous comments 31 & 32).
17. Provide details/discussion in Section 4 B to address acceptance/conveyance of local offsite flows from the east. The grading plan should clearly demonstrate continued acceptance of such existing flow upon development.
18. Revise Section 5 B to reflect: a) ANNUAL inspection report requirements; and b) the Homeowners Association as being responsible for the maintenance/upkkee/liability of the detention/retention basin and drainage structures (for consistency with the Plat and Development Standard requirements).
19. Discuss, depict, and label in the report the proposed vehicular basin maintenance access ramp. Ramps must typically be 15' wide with a maximum slope of 15%, in conformance with Section 14.3.4 of Development Standard 10-02.0 (Drainage Standard Manual).
20. Include a soils report with the resubmittal package.
05/26/2005 FRODRIG2 COT NON-DSD REAL ESTATE Approved No objection
06/04/2005 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

June 4, 2005

Kent Delph
Delph Engineering
221 N. Court Ave
Tucson, AZ 85701

Subject: S04-148 Bonillas Parkway Plat

Dear Kent:

Your submittal of May 4, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

5 Copies Revised Plat (zoning, addressing, engineering, landscaping, DSD)

4 Copies Revised Landscape Plan (engineering, zoning, landscaping, DSD)

2 Copies Revised Drainage Report (engineering, DSD)

2 Copies Soils Report (engineering, DSD)

ASSURANCES TO BE SUBMITTED TO THE CDRC OFFICE

Should you have any questions, please call me at 791-5608.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 882-6570
06/05/2005 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied See Recordation file for letter