Plan Number: S04-146
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S04-146
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/20/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) The landscape border shall be recorded as common area and maintained by the homeowners association (HOA) if a homeowners associations is formed. The subdivision CC&Rs and shall reference the maintenance standards in Sec. 3.7.6.

The DSD Director may allow the recording of a public use easement with the subdivision plat in cases where the requirements of this section is the only reason for the creation of an HOA. However, the response letter indicates that an HOA will be formed. Identify, label and dimension the Common areas on the final plat, landscape plan and grading plan. LUC 3.7.2.4.A.1.c

2) Demonstrate compliance with LUC 3.7.2.4.A.4 along Elvira Road on the landscape plans. The unpaved right-of-way area
is required to comply with the dust control provisions.
LUC 3.7.2.4.A.4 states "Except as otherwise provided by this Division, the area between the right-of-way line and sidewalk and the area between the sidewalk and the curb, if not covered with vegetation, shall be covered with an appropriate inorganic ground cover, such as decomposed granite".

3) Basin slopes may not exceed 2: 1 for protected slopes for depths less than three feet. However structures, such as retaining walls, are acceptable for up to 35% of the basin perimeter. Revise the plans for the basins to comply. Revise the landscape plan to include slope ratios for retention and detention basins. DS 10-01.4, LUC 3.7.4.3
09/20/2005 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: ELSTONE II

Lots 1-10

S04-146



The Final Plat for the subject project will meet this Company's easement
requirements.

Please forward any resubmittals of the final plat to this office.



Electric service will be provided to this subdivision in accordance with the
rules and regulations approved by the Arizona Corporation Commission.



Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
09/21/2005 PETER MCLAUGHLIN ZONING REVIEW Denied 1. The minimum required lot size is 7,000 square feet in the R-1 zone. Revise the size of those (2) lots which do not meet this requirement.
DS 2-03.6.4.B

2. Streets must be designed with parking on both sides of the street unless parking is provided in common areas, distributed throughout the subdivision at a ratio of one parking space per dwelling. The proposed public street is only proposed to provide for parking on one side and there is no visitor parking shown elsewhere on the plat. Revise plat and street cross-section. A DSMR will be required if parking is not to be provided on both sides of Elvira Court. If a DSMR is sought and approved, place the case number, date of approval, what the DSMR was approved for and any conditions imposed on the plat.
DS 3-01.2.4.D
DS 2-03.2.2.B.6

3. A 1-foot no-access easement must be recorded along the Elvira Court Street frontage of the non-participating parcel. Show the no-access easement and provide recordation information (docket and page) on the plat.

4. Provide recordation information (docket and page) for the access/well/utility easement running across lot 8 and providing access to lot 7.

5. Revise the perimeter yard setbacks to be based on the greater of 6 feet or 2/3 the height of exterior structure wall. Revise street yard setbacks to be based on Table 3.2.6.I of the LUC for developing area setbacks along street with ADT of 140 or less.
LUC 3.2.6.4
LUC 3.2.6.5
09/30/2005 LOREN MAKUS ENGINEERING REVIEW Approved DATE: September 30, 2005

To: Patricia Gehlen
CDRC/Zoning Manager
FROM: Loren Makus, EIT
Engineering Division


SUBJECT: Elstone II
Plat S04-146 (Third Review)
T15S, R13E, Section 13

RESUBMITTAL REQUIRED: None

The Plat (TP) and Drainage Report (DR) have been reviewed by the Engineering Division and we recommend approval at this time.

If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate
10/10/2005 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

October 10, 2005

Lloyd Rogers
Rogers Engineering
1765 Klamath Drive
Tucson, AZ 85704

Subject: S04-146 Elstone II Final Plat

Dear Lloyd:

Your submittal of September 14, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

2 Copies Revised Final Plat (landscaping, DSD)

2 Copies Revised Landscape Plan (landscaping, DSD)

IF CC&R'S ARE PROPOSED, PLEASE SUBMIT THE NUMBER OF COPIES DETAILED BELOW:

4 Copies CC&R's (Zoning, Landscape, Engineering, DSD)


Should you have any questions, please call me at 791-5608 ext. 1179.



Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 888-8571