Plan Number: S04-146
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL- OTHER SUBDIVISION REVIEW

Plan Number - S04-146
Review Name: RESUBMITTAL- OTHER SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/15/2005 MARILYN KALTHOFF START PLANS SUBMITTED Completed
06/17/2005 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-146 ELSTONE II SUBDIVISION / REVISED OTHER SUBDIVISION REVIEW
DATE: JUNE 17, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


Deeds recorded separately with legal descriptions will be required in order to address parcels



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
06/22/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) A landscape easement is required along Elvira Road per LUC 3.7.2.4.A.2.c. The easement shall require the abutting property owner to install and maintain a landscape border in accordance with the standards in Article 3, Division 7 of the Land Use Code. Label and dimension the landscape easement on the final plat, grading plan, and the landscape plan.

2) Demonstrate compliance with LUC 3.7.2.4.A.4 along Elvira Road on the landscape plans. The unpaved right-of-way area
is required to comply with the dust control provisions.
06/24/2005 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera Principal Planner

PROJECT:
Elstone II Subdivision
S04-146
Final Plat

TRANSMITTAL: June 24, 2005
DUE DATE: June 29, 2005

The Zoning Review Section at the Development Services Department approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

1. Revise all year dates in the Approval Block and Recording Data Block, etc to read correctly as 2005.
DS 2-03.6.2

Should the CDRC recommend approval of the final plat, please have the applicant submit the executed final plat for signature, and a memo stating that the members of the CDRC have approved the final plat. When these items are received, along with forty-four half-sized prints of the final plat, the final plat will be scheduled for consideration at the next available Mayor and Council meeting.


If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
06/27/2005 LOREN MAKUS ENGINEERING REVIEW Denied DATE: June 27, 2005

To: Craig Gross
Planning Administrator
FROM: Loren Makus, EIT
Engineering Division


SUBJECT: Elstone II
Plat S04-146 (Second Review)
T15S, R13E, Section 13

RESUBMITTAL REQUIRED: Final Plat (Minor Subdivision), Drainage Report

The Plat (TP) and Drainage Report (DR) have been reviewed by the Engineering Division and we do not recommend approval at this time. The following review comments must be addressed.

Plat Comments:
1. As previously commented, provide a concept grading plan showing driveway locations, configuration of the retention basins including maintenance access. Show how the driveway width and separation requirements will be met. Driveways must be a minimum of 10 feet wide and a minimum of 12 feet apart.
2. As previously commented, revise the drainage report to include the basin maintenance checklist and maintenance and inspection requirements.
3. I previously commented that maintenance requirements must be included in the CC&Rs and in the Drainage report and on the Plat. The CC&Rs and Plat were revised to indicate that the homeowner's association will be responsible for maintenance. Explain how the maintenance responsibillities will be allocated if a homeowner's association is not formed.
4. Add the required note establishing that the subdivision is in a service area with an assured water supply.
5. Explain how the assurances will be handled. A complete assurances package must be submitted and approved before the plat can be submitted to mayor and council for approval.
6. Revise the easement descriptions to indicate that they are created by this Plat or include recordation information for each easement.
7. Provide at least two found and fully described monuments to define the basis of bearing as describe in Development Standard 2-03.6.5.C.1.

Drainage Report Comments:
8. As previously commented, revise the drainage report to include the basin maintenance checklist and maintenance and inspection requirements.

Submit a revised plat, and a revised drainage report. Include a detailed response letter, detailing how each comment has been addressed.
If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate
06/28/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: ELSTONE II
Lots 1-10
S04-146

Tucson Electric Power Company (TEP) has reviewed the final plat submitted
for review June 15, 2005. TEP is unable to approve the plat at this time.

In order for this Company to approve the final plat, the following will be
required.

* Depict the additional 4' easements at the transformer locations on
sheet 2.
* The easements should be depicted as granted by the plat not as
proposed easements.

Show all requested easements on the resubmittal of the final plat. Submit
two bluelines to the City of Tucson for TEP's final approval.


Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
06/28/2005 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this other subdivision review.

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
07/09/2005 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Denied may not be recorded until approved.
07/09/2005 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 9, 2005

Lloyd Rogers
Rogers Engineering
1765 Klamath Drive
Tucson, AZ 85704

Subject: S04-146 Elstone II Final Plat

Dear Lloyd:

Your submittal of June 15, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

5 Copies Revised Final Plat (zoning, landscaping, engineering, TEP, DSD)

4 Copies Revised Landscape Plan (zoning, landscaping, engineering, DSD)

2 Copies Drainage Report (engineering, DSD)


Should you have any questions, please call me at 791-5608 ext. 1179.



Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 888-8571