Plan Number: S04-120
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S04-120
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/10/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/15/2005 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-120 DESERT SHADOWS / REVISED TENTATIVE PLAT
DATE: MARCH 15, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1: Add Place or Court to Desert Stone.
03/15/2005 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-120 DESERT SHADOWS / REVISED TENTATIVE PLAT
DATE: MARCH 28, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


Approve on condition that Place or Court is added to Desert Stone on Final Plat



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
03/19/2005 PETER MCLAUGHLIN ZONING REVIEW Approved
03/25/2005 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this TP.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
03/25/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) [Previous comment, unresolved]
"Show any plantings required by the Department of Planning and Urban Design for the streetscape on the landscape plan. We strongly encourage the use of native tree species to compensate for the loss of native plants on the site. Aerial photos of the site from 2002 clearly indicate the presence of many trees. No native plant preservation plan has been approved."
A plan is required prior to approval.

2) Revise the planting plan to include 50% vegetative coverage of the street landscape border per LUC 3.7.2.4.A.5
Additional plantings may be required. Provide calculations per DS 2-07.2.2.A.2.g.

3) Identify the location of the refuse storage area and any required screening. DS 2-07.2.2.A.3

4) [Previous comment, unresolved] "All landscaping and screening must comply with the sight visibility requirements of Development Standard 3-01.0. Plant materials located within sight visibility triangles should consist of ground cover or low-growing vegetation of a species that will not grow higher than thirty (30) inches. Alternately, plants taller than thirty inches may be located outside of the SVT. Revise the plan to locate the Caesalpinia pulcherrima shown east of the entrance behind the SVT."

5) [Previous comment, unresolved] "The native plant application for exception is not yet approved. The photos received do not clearly indicate that no protected plants exist on the site. Provide additional close-up photos of any trees on the perimeter of the site or in the adjacent public right-of-way areas."

6) Decomposed granite is also required in the adjacent right-of-way area per LUC 3.7.2.4.A.4. Revise to clarify.

7) Revise general note 6 on the tentative plat to exclude refuse collection from the designation for Common Area A.

Resubmittal of the tentative plat is required. In addition, submittal of landscape and native plant preservation plans is required.
03/25/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approv-Cond DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S04-120 Desert Shadows 03/25/05

(XXXX) Tentative Plat
() Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Grant Alvernon Area Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 03/24/05

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(XXXX) Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
(XXXX) Other - Elevations

REVIEWER: D. Estolano 791-4505 DATE: 03/24/05

URBAN PLANNING AND DESIGN COMMENTS
Desert Shadows – S04-120

Because this is a Residential Cluster Project (RCP), it must be in conformance with the design policies and criteria of the Grant Alvernon Area Plan, the General Plan, and the Design Guidelines Manual. In addition, the allowance of the RCP is based on the purpose to provide greater flexibility and creativity in the design of clustered residential developments.

When RCP site areas are less than four acres in size, the single-family structures need to be architecturally compatible with single-family structures on adjacent parcels. Please show an elevation of the architectural style(s) in the proposed development.
03/25/2005 PATRICIA GILBERT ENGINEERING REVIEW Approv-Cond TO: Craig Gross; CDRC Coordinator DATE: March 25, 2005

SUBJECT: Engineering review of the Desert Shadows Tentative Plat. The activity number is S04-120.

SUMMARY: The Tentative Plat and Drainage Report were received by Engineering on March 10th, 2005. Engineering has reviewed the received items recommends approval of the Tentative Plat and the Drainage Report.

CONDITIONALLY APPROVED: TENTATIVE PLAT AND DRAINAGE REPORT

GENERAL COMMENTS

1. The Drainage Report was reviewed for Tentative Plat purposes only.

2. Please include the Assurance Package with the Final Plat submittal. This package must include the original Third Party Trust, the original Amendment to Trust, a copy of the Trust Agreement, a copy of the Deed, and a Title Report.

3. Include a copy of the CC&Rs with the Final Plat submittal. The specific maintenance notes specified in the Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 14.3.2 must be included on the Final Plat or in the CC&Rs. The term "owner" in the maintenance notes is to be replaced with "Homeowners Association".

4. Please provide a copy of the boundary closure calculations with the Final Plat submittal.

5. A Grading Plan and Permit will be required. Proposed grading in excess of 5,000 yards is designated "engineered grading" and a soils engineering report is required with the Grading Plan submittal. Development Standard 11-01. The Soils Report must also address the requirements detailed in the Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 14.2.6.

6. Proposed fills in excess of two feet above existing grade at any location in the outer one hundred feet of the developing site adjacent to residentially zoned property require the procedure outlined in DS 11-01.8. This process must be complete prior to Grading Plan approval.

7. Proposed developments disturbing areas exceeding 1 acre are subject to NPDES requirements. Contact Patricia Gilbert, 791-5550 for submittal requirements.

8. All proposed easements must be shown in a surveyable manner on the Final Plat.


The next submittal must address the following items:

TENTATIVE PLAT

1. For plat clarity include in a general notes that each home will have individual solid waste pick up.

2. Remove the verbiage, " And Refuse Collection Area," from the title block.

3. Include in a general note the DSMR the case number and a general note describing what the DSMR was for and any conditions that apply on the plat
03/25/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approv-Cond URBAN PLANNING AND DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S04-120 Desert Shadows 05/27/05

(XXXX) Tentative Plat
( ) Development Plan
(XXXX) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other (Grading Plan)

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Grant Alvernon Area Plan
GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: n/a

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
(XXXX) RCP Proposal Complies With Plan Policies
(XXXX) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( )) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: D.Estolano 791-4505 DATE: 5/27/05
URBAN PLANNING AND DESIGN COMMENTS
Desert Shadows - S04-120

The applicant has submitted photos and elevations to illustrate compatibility with adjacent parcels. Also, the applicant will be adding a general note #30 to the tentative plat stating that architectural treatment such as (pop outs, etc.) will be employed on units 1 and 12 fronting on Presidio Road. The Department of Urban Planning and Design staff requests that DSD staff confirm the changes on the mylar.
03/28/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 8, 2005

Paul Nzomo
Coronado Engineering
1010 North Finance Center Drive #200
Tucson, AZ 85710

Subject: S04-120 Desert Shadows Tentative Plat

Dear Paul:

The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the mylars. Please submit the following documents for sign-off.

1 Reproducible Oce or Photo Mylar copy of the Plat, landscape plan and NPPO.

Should you have any questions, please call me at 791-5608, ext 1179.


Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 571-1961