Plan Number: S04-114
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S04-114
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/08/2005 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-114 LIMBERLOST TOWNHOUSES/REVISED TENTATIVE PLAT
DATE: February 7, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

ON FINAL PLAT
1.) CHANGE QUATER TO QUARTER ON ALL TITLE BLOCKS.


***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***












jg
02/16/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S04-114 Limberlost Townhouses 02/15/05

() Tentative Plat
( ) Development Plan
() Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other

CROSS REFERENCE: C15-88-04

NEIGHBORHOOD PLAN: Northside Area Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: February 15, 2005

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
() Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
() Other (meeting minutes as required by Cond. 12 and color palette and corresponding elevations
REVIEWER: K. Aragonez 791-4505 DATE: 2/10/2005

Please submit to Staff the color palette with corresponding elevations and the meeting information as required by rezoning condition 5 and 12. Once information has been verified Staff will be able to approve the tentative plat and forward such approval to the CDRC office at Development Services.
02/16/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S04-114 Limberlost Townhouses 02/15/05

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
() Other (meeting minutes, color palette and corresponding elevations)

CROSS REFERENCE: C15-88-04

NEIGHBORHOOD PLAN: Northside Area Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: February 15, 2005

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
( ) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on: 2/15/05
( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: K. Aragonez 791-4505 DATE: 3/1/2005
02/17/2005 JOE LINVILLE LANDSCAPE REVIEW Approved
02/17/2005 MATT FLICK ENGINEERING REVIEW Denied S04-114 -- DSD Engineering Comments for Tentative Plat Submittal

Resubmittal Required: Tentative Plat
Landscape Plan

The DSD Engineering Division has reviewed the tentative plat submittal and does not recommend approval of the plat. The drainage report is acceptable for tentative plat purposes. The following comments are noted:

1. Differential Grading: Lots 1-11 still appear to have fill greater than 2' above existing grade. Please reexamine the grading and revise to ensure conformance with differential grading criteria.

2. Differential Grading: Detail P on Sheet 6 indicates retaining walls up to 4.6 ' high. Anything over 2' would likely be in violation of differential grading criteria.

3. C.A. "A" & "B": It's unclear where the common area delineations are for the property near Limberlost. Please clarify plat and cross-sections on Sheet 4 to indicate location of common areas.

4. There appears to be no maintenance access for the retention basin in the southwest corner and the channel. Indicate maintenance access for the drainage facilities. Access to the channel will not be allowed from Limberlost; a 1' no vehicle access easement will be required to be shown on the final plat.

5. Channel or Retention Basin: Please clarify channel/retention basin designations on cross-sections.

6. Scuppers: The scupper analyses assume a depressed curb section. If this cannot be attained, additional scupper lengths may be required.

7. Scuppers: The scupper installation leading to the retention basin will likely require a railing along the sidewalk which may cut off pedestrian or vehicle access to the retention basin from that location. Also, the use of the scupper will negate vehicle access unless the scupper is designed for vehicle loading.

8. Landscape Plan: D.G. is indicated for the retention basin and channel bottoms. The fines in crushed rock and decomposed granite must be removed prior to installation in a retention basin. Otherwise, even with the installation of a bleed pipe, uneven spots in the basin will not drain properly due to the fines clogging the soil surfaces. Within the channel, it is likely that the d.g. will be washed away by the flow in the channel.

Matt Flick, PE
02/26/2005 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: S04-114 (RCP)
Limberlost Townhouses, Lots 1-49 and Common Areas "A", "B", and "C"
Tentative Plat

TRANSMITTAL: 02/26/05

DUE DATE: 02/17/05

COMMENTS:

1. The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

2. Revise general note 18 on sheet 3 to state that building setback is based on the greatest of 10 feet or ¾ the height of the structure from the property line.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

C:\planning\cdrc\tentativeplat\S04114tpca.doc
02/28/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed