Plan Number: S04-113
Parcel: Unknown

Address:
1007 E IRWIN PL

Review Status: Completed

Review Details: ASSURANCES

Plan Number - S04-113
Review Name: ASSURANCES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/26/2005 MARILYN KALTHOFF START ASSURANCES RECEIVED Completed
05/26/2005 MATT FLICK ENGINEERING FOR ASSIGNMENT Completed TO: Patricia Gehlen; CDRC Coordinator DATE: June 24, 2005

SUBJECT: Engineering review of the Irwin Place Final Plat. The activity number is S04-113.

SUMMARY: The Assurance packet was received by Engineering on March 10th, 2005. Engineering has reviewed the received items and does not recommend approval of the Assurance packet.

APPROVED: FINAL PLAT

SUBMITTAL REQUIRED: ASSURANCES, BOUNDARY CLOSURE CALCS, CC&Rs, LOCATION MAP ON AN 8 ½ X 11 SHEET

The next submittal must address the following items:

ASSURANCE COMMENTS


1. The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet. DS 2-03.7.1.G

2. The sewer easement listed in Schedule B of the title report, number 6, shows the recording information as Docket 8244, page 813. The plat shows Docket 8244, Page 814. Which document is correct? Revise as necessary. If the plat needs to be revised ensure that the mylar reflects the change.

3. Schedule B, number 8 shows an easement for full right of flowage of water and debris and incidental purposes, recorded as Docket 8244, Page 879. This easement is not shown on the plat. Clarify.
05/26/2005 MATT FLICK ENGINEERING FOR ASSIGNMENT Completed Originals of Sheet 1 & Sheet 5 to Jose for assignment.
06/24/2005 PATRICIA GILBERT ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Coordinator DATE: June 24, 2005

SUBJECT: Engineering review of the Irwin Place Final Plat. The activity number is S04-113.

SUMMARY: The Assurance packet was received by Engineering on March 10th, 2005. Engineering has reviewed the received items and does not recommend approval of the Assurance packet.

APPROVED: FINAL PLAT

SUBMITTAL REQUIRED: ASSURANCES, BOUNDARY CLOSURE CALCS, CC&Rs, LOCATION MAP ON AN 8 ½ X 11 SHEET

The next submittal must address the following items:

ASSURANCE COMMENTS


1. The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet. DS 2-03.7.1.G

2. The sewer easement listed in Schedule B of the title report, number 6, shows the recording information as Docket 8244, page 813. The plat shows Docket 8244, Page 814. Which document is correct? Revise as necessary. If the plat needs to be revised ensure that the mylar reflects the change.

3. Schedule B, number 8 shows an easement for full right of flowage of water and debris and incidental purposes, recorded as Docket 8244, Page 879. This easement is not shown on the plat. Clarify.
06/24/2005 VICTOR DURAND ENGINEERING ASSURANCES RECEIVED/SENT TO CITY ATTORNEY Needs Review TO: Patricia Gehlen; CDRC Coordinator DATE: June 24, 2005

SUBJECT: Engineering review of the Irwin Place Final Plat. The activity number is S04-113.

SUMMARY: The Assurance packet was received by Engineering on March 10th, 2005. Engineering has reviewed the received items and does not recommend approval of the Assurance packet.

APPROVED: FINAL PLAT

SUBMITTAL REQUIRED: ASSURANCES, BOUNDARY CLOSURE CALCS, CC&Rs, LOCATION MAP ON AN 8 ½ X 11 SHEET

The next submittal must address the following items:

ASSURANCE COMMENTS


1. The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet. DS 2-03.7.1.G

2. The sewer easement listed in Schedule B of the title report, number 6, shows the recording information as Docket 8244, page 813. The plat shows Docket 8244, Page 814. Which document is correct? Revise as necessary. If the plat needs to be revised ensure that the mylar reflects the change.

3. Schedule B, number 8 shows an easement for full right of flowage of water and debris and incidental purposes, recorded as Docket 8244, Page 879. This easement is not shown on the plat. Clarify.