Plan Number: S04-113
Parcel: Unknown

Address:
1007 E IRWIN PL

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S04-113
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/09/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
05/12/2005 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Denied Tucson Electric Power (TEP) has received the final plat for this project and
is unable to approve the plat at this time. We are in the process of
completing a preliminary electric design for the project. When it is
complete we will advise you of our easement requirements.

Tom - please send me the AutoCAD for this project in order to update our
landbase. Thank you.

Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
05/17/2005 PATRICIA GILBERT ENGINEERING REVIEW Approved TO: Craig Gross; CDRC Coordinator DATE: May 23rd, 2005

SUBJECT: Engineering review of the Irwin Place Final Plat. The activity number is S04-113.

SUMMARY: The Final Plat and Assurance packet was received by Engineering on March 10th, 2005. Engineering has reviewed the received items and recommends approval of the Final Plat.

APPROVED: FINAL PLAT

SUBMITTAL REQUIRED: ASSURANCES, BOUNDARY CLOSURE CALCS, CC&Rs, LOCATION MAP ON AN 8 ½ X 11 SHEET

The next submittal must address the following items:

ASSURANCE COMMENTS


1. The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet. DS 2-03.7.1.G

2. Include the subdivision activity number near the top of the page on the Amendment to Trust.

3. On page 5 of the Agreement to Construct, the Subdivider is list as KB Home, 250 S. Craycroft Road. The plat labels the Subdivider as Sonny Skys Development. There appears to be a mistake either with the plat or the Agreement to Construct. Correct the plat or page 5 of the agreement to construct. If the plat needs to be revised ensure that the mylar reflects the change.

4. The sewer easement listed in Schedule B of the title report, number 6, shows the recording information as Docket 8244, page 813. The plat shows Docket 8244, Page 814. Which document is correct? Revise as necessary. If the plat needs to be revised ensure that the mylar reflects the change.

5. Schedule B, number 8 shows an easement for full right of flowage of water and debris and incidental purposes, recorded as Docket 8244, Page 879. This easement is not shown on the plat. Clarify.
05/23/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
05/23/2005 DAN CASTRO ZONING REVIEW Approved