Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Plan Number: S04-113
Parcel: Unknown

Address:
1007 E IRWIN PL

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S04-113
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/10/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/22/2005 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-113 TOWNHOMES AT IRWIN PLACE / FINAL PLAT
DATE: MARCH 21, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
04/06/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: TOWNHOMES AT IRWIN PLACE
Lots 1-12
S04-113

Tucson Electric Power Company (TEP) has received the final plat for review
dated March 8, 2005. This Company is unable to approve the plat at this
time.

An electrical design to determine our easement requirements will be provided
on the Approved Tentative Plat with fifteen (15) working days upon receipt
of the plat.

Please contact me at (520) 917-8745 if you have any questions.

Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
04/06/2005 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond April 4, 2005

TO: Tom Guido, P.E.
T and T Engineering, LLC

THRU: Craig Gross
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Townhomes at Irwin Place, Lots 1-12 and Common Area A
Final Plat – 1st Submittal
S04-113


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


A public Sewer Service Agreement for the proposed number of residential lots has been sent to your office. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals should be returned to Pima County Wastewater Management in order to satisfy the necessary requirements needed to approve the Mylars of the final plat.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.



If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
04/06/2005 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: April 5, 2005


RE: Assessor’s Review and Comments Regarding Final Plat
S04-113 Townhomes at Irwin Place T131430 (113-02)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.








Susan King
04/07/2005 DAN CASTRO ZONING REVIEW Denied COMMENTS
CODE SECTION/ DEVELOPMENT STANDARD

1. An applicant has one (1) year from the date of approval of the tentative plat to obtain approval and recordation of a final plat that complies with zoning and other development requirements in effect at the time of application. Since the tentative plat for this subdivision has not yet been approved, the approval date for this final plat may not be determined. In addition, the final plat may not be approved prior to approval of the tentative plat. Since the tentative plat has not yet been approved, any revisions made to the tentative plat which effect the final plat must also be made to the final plat.
L.U.C. 4.1.7.3

2. Reference recorded subdivision plats by book and page numbers in the location map.
D.S. 2-03.6.1.D.2

3. The Final Plat may not be approved until the CC&R's are reviewed and approved by the Zoning Review Section. The CC&R's must meet criteria listed in L.U.C. 3.6.1.5. Please provide a copy of the CC&R's.
D.S. 2-03.6.2.B

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.
04/12/2005 DOROTHY ROBLES COT NON-DSD REAL ESTATE Approved no objections.
04/12/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
04/12/2005 PATRICIA GILBERT ENGINEERING REVIEW Denied TO: Craig Gross; CDRC Coordinator DATE: April 12, 2005

SUBJECT: Engineering review of the Irwin Place Final Plat. The activity number is S04-113.

SUMMARY: The Final Plat and were received by Engineering on March 10th, 2005. Engineering has reviewed the received items and does not recommend approval of the Final Plat or the CC&Rs.

RESUBMITTAL REQUIRED: FP

SUBMITTAL REQUIRED: ASSURANCES, BOUNDARY CLOSURE CALCS, CC&Rs

The next submittal must address the following items:

GENERAL COMMENTS

1. The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet. DS Sec.2-03.7.1.G

FINAL PLAT

1. Reference recorded subdivision plats by book and page numbers. D.S. 2-03.6.1.D.2

2. All lettering and dimensions will be the equivalent of twelve (0.12) point or greater
in size. The purpose of this requirement is to assure that all lettering is legible when reproduced or when photographically reduced (microfilmed) for recordkeeping purposes. On the second sheet above the curve table data change the verbiage to 12 point. DS 2-03.6.1.C

3. Corner tie recordation information is to be provided on the plat. Provide identification information from the Brass Cap Survey Monument (BCSM). Identify if it is county or a city survey monument. DS 2-03.6.5.A.

4. Indicate on the plat whether all bearings and distances are calculated, measured or recorded. DS 2-03.6.5.C.5.