Plan Number: S04-107
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S04-107
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/09/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
05/17/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-107 EL RANCHO MERLITA/FINAL PLAT
DATE: May 16, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Change Tomasin Corte to Corte Tomasin on pg. 2.



















jg
05/18/2005 PAUL MACHADO ENGINEERING REVIEW Denied To: Steve Hill, P.E. DATE: May 18, 2005
Lodestar Engineering Co. LLC.
1010 N. Finance Center Drive
Tucson, Arizona 85710

SUBJECT: El Rancho Merlita, 8520 E. Wrightstown Rd.
Final Plat S04-107 (First Review)
T14S, R15E, Section 04

RESUBMITTAL REQUIRED: Final plat.

The Final plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please include a response letter to the comments along with the corrected copies with re-submittal.
2. Please submit a copy of the subdivision boundary closure calculations.
3. Please re-label all common areas that may be used in a dual and/or single use capacity. For example, a Ret./Det. Basin may also be used as a recreation facility or only as a drainage facility and this must be reflected on the Final Plat. A key note explaining the labels will be sufficient, ie.:
Common Area "A" - Streets
Common Area "B" - Drainage/Recreation Facilities
Common Area "C" - Recreation Facilities
Common Area "D" - Drainage Facilities
Common Area "E" - Landscaping

4. Correct the indicator for the 100-year flood line number in the legend. It should read "FL00", not "L00" per D.S. 2-03.6.1.L.
5. Include lots 3 and 7 in note 5 in case any future sub-structure in the floodplain is planned on the property per D.S. 2-03.6.2.E.
6. Per note no. 11, show the EHS on the plat per D.S. 2-03.6.4.E.
7. Show lot access point for lot 2 with a star per D.S. 2-03.6.4.G.
8. Show a NVAE for lot 2 on the adjacent side of the access point per D.S. 2-03.6.4.H.
9. Label all facilities and/or easements as to being public or private per D.S. 2-03.6.4.A.
10. Indicate tract boundary lines; right-of-way and centerlines of streets, easements…….with accurate dimensions, bearings, or deflection angles and radii, arcs, and central angles of all curves per D.S. 2-03.6.5.B. Arc's along the boundary and centerline of Wrightstown Rd are missing.
11. All boundary monumentation must be labeled as "found" or "set" per D.S. 2-03.6.5.4.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/8520 E. Wrightstown Rd. FP
05/27/2005 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approv-Cond May 27, 2005

TO: Steven Hill, P.E.
Lodestar Engineering Company, LLC

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: El Rancho Merlita, Lots 1-16 and Common Areas A-C
Final Plat - 1st Submittal
S04-107

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

1. SHEET 2. Delete the 20-foot public sewer easement within Common Areas A & C as those common areas are being dedicated as access points in the Dedication. Public sewer easements are no longer required within common areas for this reason.

2. SHEETS 2 & 3. Show the recording information for the existing public sewer easements.

3. A public Sewer Service Agreement for the proposed number of residential lots has been sent to your office. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals should be returned to Pima County Wastewater Management in order to satisfy the necessary requirements needed to approve the Mylars of the final plat.

4. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.



If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
06/07/2005 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: June 7, 2005


RE: Assessor’s Review and Comments Regarding Final Plat
S04-107 El Rancho Merlita T141504 (133-07)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

x Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.







Susan King
06/09/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: EL RANCHO MERLITA
Lots 1-17
S04-107

Tucson Electric Power Company (TEP) has received the final plat for review
submitted May 9, 2005. This Company is unable to approve the plat at this
time.

TEP is in the process of completing the redesign of the electrical
facilities, once it is completed a copy will be sent to you along with our
easement requirements.

Please contact me at (520) 917-8745 if you have any questions.


Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
06/10/2005 FRODRIG2 COT NON-DSD REAL ESTATE Approved No objection
06/11/2005 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: S04-107-El Rancho Merlita, Lots 1-16, and Common Areas A, B, and C
Final Plat

TRANSMITTAL: 06/11/05

DUE DATE: 06/07/05

COMMENTS:

1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before May 8, 2005. As of this final plat review date the tentative plat has not been approved therefore the one year date of the final plat approval is based on the date of submittal of the final plat documents. Once the tentative plat has been approved the approval date of the final plat will be on one year from the tentative plat approval date. This date will be provided on a future review of the final plat.

2. Please insure that the words Book and Page along the lower and upper right corners of the plan sheets are with the margins and are legible. DS 2-03.6.1.G

3. Add the under line after the word "BOOK" to the Recording Data text block. Ds 2-03.6.3.D

4. Corner lots may be designated with a star symbol indicating which street will be used for access. Use of this designation may limit design options for access. In instances where the City, for safety reasons, limits accessibility, a one-(1) foot no access easement will be required. Show star where applicable. DS 2-03.6.4.G

5. Provide a copy of the document that abandons the ingress/egress easement in lot 5. Add the recordation data to the plat.

6. The title on the title sheet of the CC&R's document must include the lot numbers as well as the Common Areas.
If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\finalplat\S04107fp.doc
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, tentative plat, final plat, CC&R's and additional requested documents.
06/13/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed