Plan Number: S04-103
Parcel: Unknown

Address:
725 S TUCSON BL

Review Status: Completed

Review Details: RESUBMITTAL- OTHER SUBDIVISION REVIEW

Plan Number - S04-103
Review Name: RESUBMITTAL- OTHER SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/21/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
10/22/2004 JIM EGAN COT NON-DSD FIRE Approved
10/27/2004 JCLARK3 ENV SVCS REVIEW Denied * Have no idea if these lots are house lots or bussiness lots. If house lots is the refuse susposed to be picked up on Speedway or is a centralized collection point going to be provided?
11/03/2004 FRODRIG2 PIMA COUNTY WASTEWATER Denied November 2, 2004

TO: Timm Dixon, E.I.T.
Arcadis

THRU: Craig Gross
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Huntington Park Plaza
Subdivision Exception – 2nd Submittal
S04-103


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Install a cleanout at the south property line and then, run the sewer straight north, parallel to the north-south property line.

Show the size (6 inches) and the length of the proposed sewer between the cleanouts.

The private sewer easement limits need to reach, as a minimum, the property line between lots 1 and 2.

Label the private sewer easement to be granted BY SEPARATE INSTRUMENT.

Delete the second sentence of the Dedication.

We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents.

The next submittal of this project will be the 3rd submittal. A check for the review fee of this submittal in the amount of $39.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.

If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
11/05/2004 PETER MCLAUGHLIN ZONING REVIEW Approved TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
S04-103
Huntington Park Plaza
Record of Survey

TRANSMITTAL: November 5, 2004
DUE DATE: November 5, 2004

The Zoning Review Section at Development Services has reviewed and recommends approval of the Record of Survey. However, should there be any changes requested by other CDRC members, we request copies of the corrected Record of Survey to verify that those changes do not affect any zoning requirements.


If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
11/08/2004 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
11/08/2004 CRAIG GROSS ZONING-RECORDATION REVIEW Passed