Plan Number: S04-102
Parcel: Unknown

Address:
2921 E ALLEN RD

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S04-102
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/10/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/16/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: ALLEN ROAD TOWNHOMES
Lots 1-18
S04-102

Tucson Electric Power Company (TEP) has reviewed the final plat dated
February 8, 2005. TEP is unable to approve the plat at this time.

In order for this Company to approve the final plat, the following will be
required.

* The Dedication must include the granting of easements, as shown, to
all public utility companies for access, installation and maintenance.

Show the requested requirement on the resubmittal of the final plat. Submit
two bluelines to the City of Tucson for TEP's final approval.


Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8745
Cell Phone: (520) 904-2668
Fax: (520) 917-8700
02/18/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-102 ALLEN ROAD TOWNHOMES/FINAL PLAT
DATE: February 16, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:



Mantes sounds like another street name. Please choose a new name.

















jg
03/03/2005 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: March 3, 2005


RE: Assessor’s Review and Comments Regarding Final Plat
S04-102 Allen Road Townhomes T131429 (112-01)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal. Per phone conference with Mr. Derek Roberts of Arcadis, Common Area “D” will be added to the title blocks and the labels for Common Areas “B” and “D” west of Toulon Avenue will be corrected on sheet 1.
If there area nay questions, please contact Susan King at 740-4391.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.






Susan King
03/07/2005 DAN CASTRO ZONING REVIEW Approv-Cond The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

1.
Revise CC&R's as follows: on the cover sheet please reference all subdivisioninformation found in the title block located on each sheet of the final plat (i.e. subdivision name, number of lots, common areas, and RCP designation).


If you have any questions about this transmittal, please call Dan Castro at (520) 791-5608.
03/07/2005 MATT FLICK ENGINEERING REVIEW Denied S04-102 DSD Engineering Comments for Final Plat Submittal

Received: Final Plat (paper)
Assurances (copy)
CCRs (copy)

Resubmittal Required: Final Plat
Assurances
CCRs

DSD Engineering has reviewed the final plat, assurances and CCRs and does not recommend approval. The following comments are offered:

Final Plat

Sheet 1:

Regarding the title as it relates to Common Area "D", the title listed at the top of the sheet differs from that shown in the title block of Sheets 1-3. Please revise the title block to match the title at the top of the sheet or the assurances (see related comment).

Eliminate General Note # 7. The floodplain use permit, if required, will be handled with grading plan processing. Leaving this note on would have the effect of requiring floodplain permits for all future improvements to these lots.

Sheet 2:

Provide a bearing for the northern property line of Lots 14-18 or provide a dimension (similar to L18) for the distance between the NE corner of Lot 14 and the subdivision property line.

Tie down location of TEP easements.

Indicate line break symbology for the 654.28' and 1307.79' dimensions along the Allen Road centerline.

Indicate the meaning of the "1" in the R1 notation for the 255' dimension from Allen Road to the subdivision corner.

Verify if the dimension from north edge of wall to property line is measured in inches or feet.

Set monuments for the boundaries between C.A. "A" and C.A. "C" (2 locations) along the southern boundary of the subdivision. Provide distances to these points from another set or found point and from the Chartres Avenue centerline.

Indicate bearing of line connecting Allen Road centerline and that of Chartres Avenue. It cannot be easily inferred since the subdivision boundary and Allen Road centerline are not parallel.

What is dimension B33 pointing to?

Indicate bearing for 12.51' dimension between C28 & C29.

Indicate bearing for 35.07' dimension along Chartres Avenue.

Indicate recording information for sewer easement along eastern property line.

Please note that if the grading plan indicates that the ponding from the retention basin impinges on C.A. "A", the flood-prone area will need to be delineated.

Sheet 3:

Please provide ties from the property corners to the boundaries of the landfill on Lots 3, 4 & 5. Though not required, it will greatly assist homeowners and the HOA in locating this boundary.

Assurances:

The "Recitals" in the Agreement to Construct, the legal description in Exhibit "A", and Item # 1 in the Amendment to Trust all refer to Common Area "D" (Detention/Retention). This differs from both presentations on the final plat. Please ensure consistency between all descriptions.

CCRs:

The CCRs lack the necessary drainage and retention basin maintenance language. Sections 14.3.2 and 14.3.3 of the Standards Manual for Drainage Design and Floodplain Management (SMDDFM) should be consulted for the appropriate language.

I can be contacted at Matthew.Flick@tucsonaz.gov or 791-5550, ext. 1192.

Matt Flick, PE
Engineering Manager
03/14/2005 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond March 13, 2005

TO: Derek Roberts, P.E., Arcadis

THRU: Craig Gross, CDRC Manager
City of Tucson Development Services Dept.

FROM: ____________________________________
Tim Rowe, P.E., (520-740-6563) representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: Allen Road Townhomes, Lots 1-18 and Common Areas A-D
Final Plat – 1st Submittal
S04-102


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Sheet 1: As we have previously discussed, the on-site sewers for this development will need to be private, rather than public, as they cannot be designed to PCWMD's Design Standards. Add PRIVATE SEWERS to the list of the property owners association's responsibilities in the Dedication.

Sheet 1: Delete General Note 6 regarding public sewer easements.

A formal Sewer Service Agreement will not be required for this project, due to it small size and no requirement for public sewers to be built.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.



If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.

Copy: Project
G-2004-167
03/17/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
03/17/2005 FRODRIG2 COT NON-DSD REAL ESTATE Approved