Plan Number: S04-097
Parcel: Unknown

Address:
32 E DELTA RD

Review Status: Completed

Review Details: OTHER SUBDIVISION REVIEW

Plan Number - S04-097
Review Name: OTHER SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/30/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/02/2004 JOE LINVILLE LANDSCAPE REVIEW Approved
08/02/2004 JIM EGAN COT NON-DSD FIRE Approved The plan is approved August 3, 2004.
08/04/2004 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-097 LORD PROPERTY / OTHER SUBDIVISION REVIEW
DATE: AUGUST 3, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


1: Include a Location Map.

2: Spell out all Street Suffixes.

3: Include what portion of Lot 27 this is in the Title Block.

4: Number lots.
08/06/2004 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved NO COMMENT
S04-097
CHUMBLER'S REALTY, INC.
LORD PROPERTY
08/19/2004 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: LORD PROPERTY
S04-097

Tucson Electric Power Company has reviewed and approved the plans dated July 22, 2004.

Please provide full electrical and site plans with the recorded property splits. If easements are required, they will be secured by separate instrument. Submit the requested information a minimum of six (6) weeks prior to requiring service.

Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8745
Cell Phone: (520) 904-2668
Fax: (520) 917-8700
08/19/2004 JCLARK3 ENV SVCS REVIEW Approved * No known landfill w/in 1000 feet of this property split.
* Residential service will be 90 gallon APC's to be service at curb side off Delta RD.
08/25/2004 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
Lord Property-Record of Survey
S04-097
Tentative Plat

TRANSMITTAL: August 25, 2004
DUE DATE: August 26, 2004

1. The submitted survey is being reviewed as a Record of Survey.

2. Sixth Avenue is a designated Major Street and Route (MS&R) and street front building setbacks are required to be the greater of 21 feet or the height of exterior structure wall dimensioned from back of future curb location. Revise drawing by showing future curb location and dimensioning setback at 21 feet from back of future curb.

3. Provide lot coverage calculations for the developed east and west parcels per LUC 3.2.9.

4. Land Survey Exception Record of Survey Format:

a. Each sheet will include a two (2) inch margin on the left side and one-half (½) inch margins on the remaining sides.

b. All lettering and dimensions will be the equivalent of twelve (0.12") point or greater in size. The purpose of this requirement is to assure that the lettering is legible when reproduced or when photographically reduced (microfilmed) for record keeping purposes. Revise all lettering to meet this minimum size.

c. Provide a small, project-location map drawn at a scale of 3" = 1 mile. If possible, the map should be located in the upper right corner of the sheet. On multiple sheet drawings, the map will be located on the first sheet. The location map is to provide the following information:

Show the subject property approximately centered within a one (1) square mile area.

Identify conditions within the square mile area, such as land surveys, major streets, major watercourses, and railroads. Reference recorded land survey plats by book and page numbers.

Section, township, and range; section corners; north arrow; and the scale will be labeled.

d. Place the words "Book ____ Page ____" in both the upper and lower right corners outside the margin line. The blanks will be completed by the Pima County Recorder's Office at the time of recordation.

e. A title block with the following information is to be provided approximately in the lower right corner of the first page of the Record of Survey.

1. The first line of the title block must read, "RECORD OF SURVEY".

2. Provide the proposed name of the Land Survey Exception.

3. The number of proposed lots is to be noted.

f. The following general notes will appear on the record of survey. Additional notes specific to ea ch project are required where pertinent.

g. Ownership and Preparation Notes:

1. List the names, addresses, and telephone numbers of the primary owners of the site.

2. List the name, address, and telephone number of the person, firm, or organization that prepared the record of survey and the applicable registration number, along with the seal and signature, of the land surveyor or professional engineer.

h. Zoning and Land Use Notes:

1. Place the S04-097 Land Survey Exception case number in the lower right hand corner of the plan next to the title block.

2. List as a general note: "Existing zoning is ____."

3. Add the following note: "The number of lots is ____."

4. Add a note listing the gross area of the existing parcel.

5. Add the following note, "There will be no further division of lots without the expressed approval of the City of Tucson."

6. Sixth Avenue is a designated Major Street and Route. On single family projects bounded or intersected by a Major Street or Route, list the following note: "Lots with frontage on a street designated a Major Street or Route shall have ingress-egress designed in a manner so that motor vehicles do not back out onto the Major Street or Route, through the use of circular drives, turnarounds, or other similar solutions."

i. Utilities Note.

1. All plans are to include the following note: "Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public."

5. Record of Survey Standard Paragraphs:

a. Certificate of Survey. Include the following paragraph signed and sealed by a Registered Professional Land Surveyor:

CERTIFICATE OF SURVEY

"I hereby certify that the boundary survey as shown on this Record of Survey was performed
under my direction and that all existing or proposed survey monuments and
markers shown are correctly described. I further certify that this Record of Survey was prepared under my direction."

b. Dedication. Include the following paragraph:

DEDICATION
"We the undersigned, hereby warrant that we are the owners and the only parties having any interest in the land shown on this plan, and we consent to the split of said land in the manner shown hereon."
"We hereby grant to the Public and all utility companies all easements as shown hereon for the purposes of access, installation, and maintenance of public sewers and utilities and other uses as designated by this plan."
"We, the undersigned, do hereby hold harmless the City of Tucson, its successors and assigns, their employees, officers, and agents from any and all claims for damages related to the use of the property depicted on this plan now and in the future by reason of flooding , flowage, erosion, or damage caused by water, whether surface flood or rainfall."

Add the signature lines for the property owners.

c. Recording Data. Include a 5" x 5" box for the County Recorders stamp. The title over the box must read, "RECORDING DATA".

6. Existing Conditions:

a. All easements of record will be drawn on the plan, and recordation information, locations, widths, and purposes shall be included.

b. The following information regarding the existing public right-of-way will be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

c. The following information regarding existing utilities will be provided: the location and size of water wells, water pumping plants, water reservoirs, water lines, fire hydrants, and storm and sanitary sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; the Pima County Wastewater Management Department (PCWMD) reference number; locations of gas lines, electric and telephone lines, poles, and on-ground junction boxes, and street lights. If water mains and sewers are not located on or adjacent to the tract, indicate the direction, distance to, and sizes of those nearest the property. Show sewer line invert elevations.

d. Sixth Avenue is a Major Street and Route with a future right-of-way of 100 feet. Only a portion of this right-of-way width is shown as existing on the survey drawing. Projects bounded by streets having only a portion of the Major Streets and Routes (MS&R) right-of-way width will be required to dedicate right-of-way to the MS&R width. Right-of-way dedication is required prior to Land Survey Exception approval. Dimension the future right-of-way for Sixth Avenue on the drawing and include right-of-way dedication recordation information on the plan.

7. Proposed Conditions:

a. All proposed easements (utility, sewer, drainage, access, etc.) are to be dimensioned and labeled as to their purposes and whether they will be public or private. Recordation information (docket and page) must be included on the plan prior to final approval.

b. Show locations of all proposed driveways. A driveway can only access two units. Accessing three or more units off a single access point requires the development of a street or PAAL. The development of a street or PAAL requires a plat.
DS 2-03.11
If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
Pmclaug1\mydocuments\Peter\tentativeplats04\S04-097ROSrev.doc
08/26/2004 LOREN MAKUS ENGINEERING REVIEW Denied To: Craig Gross, CDRC Manager
Subject: Lord Property: Other Subdivision Review
Reviewer: Loren Makus
Date: 26 August 2004
CDRC Case: S04-097

Resubmittal Required: Revised Record of Survey

Summary: Engineering Division has reviewed the Record of Survey for the proposed subdivision. Approval of the subdivision is not recommended at this time. The applicant should include a detailed response letter describing how each comment was addressed.

As indicated in the presubmittal conference, sidewalk and driveway aprons along Delta Road must be completed before the subdivision is approved. The new sidewalk must be 5 feet wide. A right of way permit from the Tucson Department of Transportation will be required.

The Record of Survey must meet the format requirements of the proposed standard.
1. All lettering must be a minimum of twelve-point type so that the plan will be legible when microfilmed for recordkeeping purposes.
2. Provide a two-inch margin on the left side of the sheet.
3. Include the words "Book _____ Page ______" in both the upper and lower right corners, outside the margin line.
4. Provide a location map, at a scale of 3" = 1 mile at the upper right corner of the sheet.
a. Include the location of the property in the approximate center of the location map.
b. Identify conditions within the square mile area, such as land surveys, major streets, major watercourses, and railroads. Reference recorded plats by book and page numbers.
c. Label section, township, range, section corners, north arrow and scale.
5. List the names, addresses and telephone number of the primary owners of the site.
6. List the gross area of the existing parcel.
7. Add a not stating, "Lots with frontage on a Major Street or Route shall have ingress-egress designed in a manner so that motor vehicles do not back out onto the Major Street or Route, through the use of circular drives, turnarounds or other similar solutions."
8. Add a note stating, "Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public."
9. Add the dedication paragraphs and signature lines as described in Development Standard 2-03.6.3.B.
10. Include a 5" X 5" box for the County Recorder's Stamp. The title over the box must read "RECORDING DATA."

If the applicant has any questions, I can be reached at 520.791.5550 ext 1161 or at loren.makus@tucsonaz.gov.

Loren Makus, E.I.T.
Senior Engineering Associate
08/27/2004 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: August 25, 2004

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks, Parks and Recreation

SUBJECT: CDRC Transmittal, S04-097 Lord Property: Other Subdivision Review

CC: Craig Gross, Development Services


Staff has no comments.




Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov
08/29/2004 DALE KELCH COT NON-DSD TRAFFIC Denied Sorry about the wrong subject before.

>>> Dale Kelch 8/27/2004 11:30:41 AM >>>
Traffic Engineering REJECTS this other subdivision review:

1. Show and label both existing and future ROW (DS 2-03.2.3.D)

2. Add a note to read " Any access to the West parcel from 6th Ave shall be in accordance with the Access Management Guidelines."


D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
08/31/2004 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond August 27, 2004

TO: Jim Chumbler, Chumbler's Realty, Inc.

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: The Lord Property aka Judge Emery's Poultry Colony
- Submittal
S04-097


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


This project will be tributary to the Roger Road Wastewater Treatment Facility via the Santa Cruz Interceptor. Treatment and conveyance capacity for this project is available.

Based on our records for this geographical area, the new lot would qualify for the Participating sewer connection fee rate.

Add the project number, S04-097, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

All three lots should have their own direct connection to the public sewer system. If any of these three lots will be sharing a connection to the sewer line, a Joint Use and Maintenance Agreement will need to be drawn up, approved by PCWMD, and recorded, prior to any sewer connection permits being issued. If a Joint Use and Maintenance Agreement is necessary, please contact Ms. Ilene Deckard of the PCWMD at 740-6544 for further information.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the subdivision exception. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.




If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.
09/02/2004 FRODRIG2 COT NON-DSD REAL ESTATE Approved No comment
09/02/2004 FRODRIG2 OTHER AGENCIES PIMA ASSN OF GOVTS Approved
09/13/2004 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S04-097 Lord Property 08/13/04

() Tentative Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
(xxxxx) Other – Record of Survey

CROSS REFERENCE:

NEIGHBORHOOD PLAN: 12th Avenue/Valencia

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 8/26/04

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
(XXXX) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(XXXX) Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
(XXXX) Other – Record of Survey

REVIEWER: D. Estolano 791-4505 DATE: 08/10/04
Urban Planning and Design Comments
Lord Property, S04-0097


The 12th Avenue/Valencia Area Plan provides policy direction for this site. The Plan area is located near the Tucson International Airport (TIA), which creates noise impacts in the area. The Airport Environs Zone (AEZ), an overly zone, and the Airport Environs Plan (AEP) directly affect this site and; thus, have created High Noise Area Policies that provide specific direction. This site is located within the noise level 65 Ldn .

The regulations for the AEZ overlay zone establish: (3) the Noise Control Districts, which require the acoustical treatment of buildings located within these areas so as to increase the protection of persons exposed to high levels of aircraft noise; therefore, please:

Submit a revised record of survey with a note stating that the AEZ overlay zone affects this site with a noise level of Ldn. 65 (see attached overlay zone map).

2. Please make a note on the record of survey that this is a high noise area and that dwellings will need to be fitted with noise attenuation insulation to reduce the interior noise level to a Ldn. of 45 or less. (see attached AEZ 2.8.5.6.A.1.a. Noise Control Districts)
09/13/2004 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
09/13/2004 CRAIG GROSS ZONING-RECORDATION REVIEW Passed