Plan Number: S04-089
Parcel: Unknown

Review Status: Completed

Review Details: ASSURANCES

Plan Number - S04-089
Review Name: ASSURANCES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/14/2005 MARILYN KALTHOFF START ASSURANCES RECEIVED Completed
07/20/2005 MATT FLICK ENGINEERING FOR ASSIGNMENT Completed Original Agreement & Amendment to Doug W. for review.
08/23/2005 ELIZABETH EBERBACH ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: San Antonio Subdivision - 4th Review
ACTIVITY NUMBER: S04-089
REVIEWERS: Elizabeth Eberbach, Matt Flick
LOCATION: T14S, R13E, Sec. 22

SUMMARY: The Final Plat mylar, and other documents were received by the CDRC office on August 9, 2005. Engineering Division does not recommend proceeding with the Final Plat mylar at this time.

FINAL PLAT MYLAR AND ASSURANCES COMMENTS:
1) City of Tucson Development Standards (DS) Section No.2-03.6.1.H.1 & DS 2-03.6.4.I: There still appears to be a discrepancies with the access to south offsite properties; this must be promptly resolved. If there is conflict in the location of the basin and the access easement, a revised location of the basin shall be provided. Show changes in the drainage design, including ponding depth and limits, in a revised Drainage Report. Once the basin location and revised Drainage Report is reviewed and is acceptable, the revised location of the detention/retention areas must be clearly identified on the plat, distinguishing them from the ingress/egress/utility/parking and drainage easement(s).
2) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. Since there was no power of attorney submitted for each of the parcel owners, some of the documents need to be revised to show signatures for all parties. Pick up the assurance package from the CDRC office and address these assurance comments. Submit a completed revised compiled assurance package after revising the following:
a) All documents (Final Plat, Agreement to Construct, and Amendment to Trust) must include all parties affected by this platting. Address the following:
i) Provide clarification for as to why only one "beneficiary" appears on the Amendment to Trust, and as "subdivider" on the Agreement to Construct, when there appears to be more than one parcel owner for this project. Either provide all owners (beneficiaries or subdividers) or provide power of attorney from each for the beneficiary/subdivider listed on the Amendment to Trust/Agreement to Construct.
ii) The Title Report Special Report submitted indicates owners that do not appear on the plat; clarify whether any additional owner(s) are a part of the site area, or need to be added to the Final Plat, Agreement to Construct, and Amendment to Trust documents.
b) Correct the following for the third party trust assurances:
i) Provide an original copy of the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST which includes signature lines for each of the subdividers as listed on the mylar; revise pages 1 and 5.
ii) For the assurable items in the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST, clarify whether the ingress/egress easement to be paved is the proposed easement and/or the existing easement along the south boundary.
iii) Provide an original copy of the AMENDMENT TO TRUST / THIRD PARTY TRUST which is signed by all beneficiaries of the trust; there is only one subdivider listed on the cover and page 2.
iv) add the case number "S04-089" is at the top of the first page of the AMENDMENT TO TRUST;
v) resubmit the copy of the original Trust Agreement with the newly compiled assurance package;
vi) resubmit the copy of a sample Warranty Deed with the re-compiled assurance package;
vii) resubmit the copy of the Title Report with the re-compiled assurance package.
c) Provide a 8½" by 11" location map sheet for assurance submittals that go to Mayor & Council. Typically, these are similar to an enlarged location map on Final Plats.
d) Provide signed original financial assurances as described above.
e) Provide originals for the consents to dedicate.
3) DS Sec.10-02.14.3.2: Provide a signed original copy of the CC&R's.
a) The CC&R's shall be signed by all parties or provide a letter of authority that states that one person is the declarant.
b) Add CDRC case number S04-089 to the cover sheet.
c) CC&R's shall be notarized.
4) DS Sec.2-03.8.1.B: Submit original documents with appropriate signatures affixed since they will require recordation in conjunction with the plat.
5) DS Sec.2-03.6.5: Address the following boundary data / survey comments:
a) Clarify whether the distance / bearing data for the tie measurements are measured (M) or calculated (C) or recorded (R).
b) Provide crow's feet for "48.00", and 48.78" at right side of the plan.
6) DS Sec.2-03.6.5.B: Address the following easement comments:
a) The east portion of the sewer / access easement shows as to be abandoned. This is in conflict with access to south bounding parcel(s). Explain thoroughly in response letter how this conflict will be ameliorated.
b) Label Bk/pg or Dkt/pg for any portion of the ingress/egress easement that is abandoned.
c) In response letter, explain whether any easement items in the title report are not shown on the plat. Specifically, explain location of the communication line easement Bk76 pg84, as referenced in Title Report Schedule B item 5.
d) Assure that easements are labeled with accurate dimensions and bearings on the plat; in response letter, please explain why/whether the south ingress/egress easement has been revised on the plat.
7) For the subsequent revised grading plan, the following entities will need clarification or revision: water surface elevation for the basin / drainage areas, a typical lot grading detail, existing contours, slope information for the basin / drainage area, cross sections at north, east and south boundaries, basin dimensions, and outlet weir cross-sections. A revised grading plan may need to be submitted for review. One copy of the grading plan will be needed for the review of this revised drainage report.

For resubmittal, please submit a complete response letter, two copies of the revised drainage report, one copy of the revised grading plan for reference, the complete revised and re-compiled assurance package, signed original copy of the CC&R's, and the revised Final Plat mylar. For further clarification, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
08/24/2005 TAMI ACHONG ENGINEERING ASSURANCES RECEIVED/SENT TO CITY ATTORNEY Needs Review
08/29/2005 ELIZABETH EBERBACH ENGINEERING additional review for easement Denied DATE: August 29, 2005
TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: San Antonio Subdivision - 6th Review
ACTIVITY NUMBER: S04-089
REVIEWERS: Elizabeth Eberbach
LOCATION: T14S, R13E, Sec. 22

SUMMARY: The Final Plat mylar, and other documents were received by the CDRC office on August 9, 2005. Additional documentation (including revised copies of the Final Plat and basin routing) was submitted by Delph Engineering on 23AUG05. Engineering Division does not recommend proceeding with the Final Plat mylar at this time. The following comments are given to provide further clarification of the remaining discrepancies that need to be addressed in order to further process the package for Mayor and Council scheduling.

FINAL PLAT MYLAR AND ASSURANCES COMMENTS:
1) City of Tucson Development Standards (DS) Section No.2-03.6.1.H.1 & DS 2-03.6.4.I: There still appears to be a discrepancies with the access to south offsite properties; this must be promptly resolved. If there is conflict in the location of the basin and the access easement, a revised location of the basin shall be provided. Show changes in the drainage design, including ponding depth and limits, in a revised Drainage Report. The basin design shall be provided with natural features (earthen side slopes - no wall retention will be accepted); see DS Sec.10-01.4. Once the basin location and revised Drainage Report is reviewed and is acceptable, the revised location of the detention/retention areas must be clearly identified on the plat, distinguishing them from the ingress/egress/utility/parking and drainage easement(s). Also, to clarify ingress egress to existing Conner parcel, provide a letter from this affected property owner (and any other affected parcel owner) providing authorization to abandon the ingress/egress easement at their lot. Otherwise provide a copy of the dkt/pg for this ingress/egress easement highlighting the section where it does not require a mutual agreement to dissolve the easement.
2) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. Since there was no power of attorney submitted for each of the parcel owners, some of the documents need to be revised to show signatures for all parties. Pick up the assurance package from the CDRC office and address these assurance comments. Submit a completed revised compiled assurance package after revising the following:
a) All documents (Final Plat, Agreement to Construct, and Amendment to Trust) must include all parties affected by this platting. Address the following:
i) Provide clarification for as to why only one "beneficiary" appears on the Amendment to Trust, and as "subdivider" on the Agreement to Construct, when there appears to be more than one parcel owner for this project. Either provide all owners (beneficiaries or subdividers) or provide power of attorney from each for the beneficiary/subdivider listed on the Amendment to Trust/Agreement to Construct.
ii) The Title Report Special Report submitted indicates owners that do not appear on the plat; clarify whether any additional owner(s) are a part of the site area, or need to be added to the Final Plat, Agreement to Construct, and Amendment to Trust documents.
b) Correct the following for the third party trust assurances:
i) Provide an original copy of the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST which includes signature lines for each of the subdividers as listed on the mylar; revise pages 1 and 5.
ii) For the assurable items in the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST, clarify whether the ingress/egress easement to be paved is the proposed easement and/or the existing easement along the south boundary.
iii) Provide an original copy of the AMENDMENT TO TRUST / THIRD PARTY TRUST which is signed by all beneficiaries of the trust; there is only one subdivider listed on the cover and page 2.
iv) add the case number "S04-089" is at the top of the first page of the AMENDMENT TO TRUST;
v) resubmit the copy of the original Trust Agreement with the newly compiled assurance package;
vi) resubmit the copy of a sample Warranty Deed with the re-compiled assurance package;
vii) resubmit the copy of the Title Report with the re-compiled assurance package.
c) Provide a 8½" by 11" location map sheet for assurance submittals that go to Mayor & Council. Typically, these are similar to an enlarged location map on Final Plats.
d) Provide signed original financial assurances as described above.
e) Provide originals for the consents to dedicate.
3) DS Sec.10-02.14.3.2: Provide a signed original copy of the CC&R's.
a) The CC&R's shall be signed by all parties or provide a letter of authority that states that one person is the declarant.
b) Add CDRC case number S04-089 to the cover sheet.
c) CC&R's shall be notarized.
4) DS Sec.2-03.8.1.B: Submit original documents with appropriate signatures affixed since they will require recordation in conjunction with the plat.
5) DS Sec.2-03.6.5: Address the following boundary data / survey comments:
a) Clarify whether the distance / bearing data for the tie measurements are measured (M) or calculated (C) or recorded (R).
b) Provide crow's feet for "48.00", and 48.78" at right side of the plan.
c) Clarify distance from adjacent parcel corners to subdivision corner - specifically at southeast corner.
6) DS Sec.2-03.6.5.B: Address the following easement comments:
a) The east portion of the sewer / access easement shows as to be abandoned. This is in conflict with access to south bounding parcel(s). Explain thoroughly in response letter how this conflict will be ameliorated.
b) Label Bk/pg or Dkt/pg for any portion of the ingress/egress easement that is abandoned.
c) In response letter, explain whether any easement items in the title report are not shown on the plat. Specifically, explain location of the communication line easement Bk76 pg84, as referenced in Title Report Schedule B item 5.
d) Assure that easements are labeled with accurate dimensions and bearings on the plat; in response letter, please explain why/whether the south ingress/egress easement has been revised on the plat.
7) DS Sec.3-01.5.1: Revise the Landscape documents to reflect new location of basin. Submit the revised Landscape Plan.
8) For the subsequent revised grading plan, the following entities will need clarification or revision: water surface elevation for the basin / drainage areas, a typical lot grading detail, existing contours, slope information for the basin / drainage area, cross sections at north, east and south boundaries, basin dimensions, and outlet weir cross-sections. A revised grading plan may need to be submitted for review. One copy of the grading plan will be needed for the review of this revised drainage report with a revised Final Plat.

For resubmittal, please submit a complete response letter, two copies of the bound revised drainage report with all addenda, one copy of the revised grading plan for reference, the complete revised and re-compiled assurance package, signed original copy of the CC&R's, revised Landscape Plan, and two copies of the revised Final Plat. Once the plat is acceptable, you may pick up the Final Plat mylar to make revisions, and if the assurances are approvable, the Mayor and Council date can be confirmed / scheduled. At that point, the Final Plat mylar must be returned and processed for signatures. For further clarification, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
09/18/2005 ELIZABETH EBERBACH ENGINEERING change in assurances Denied TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: San Antonio Subdivision - 6th Review (new assurances)
ACTIVITY NUMBER: S04-089
REVIEWERS: Elizabeth Eberbach
LOCATION: T14S, R13E, Sec. 22

SUMMARY: An bond estimate was submitted for review, which was provided as the newly proposed assurance for this subdivision in lieu of the third party trust, and was submitted by Delph Engineering, with a Grading Plan on September 15, 2005. Engineering Division does not recommend proceeding with the Final Plat mylar and assurances until the prior comment letter has been addressed along with the following bond estimate comments below.

ASSURANCES COMMENTS:
1) City of Tucson Development Standards (DS) Section 2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved.
a) Add the case number "S04-089" is at the top of the estimate.
b) Provide a 8½" by 11" location map sheet for assurance submittals that go to Mayor & Council. Typically, these are similar to an enlarged location map on Final Plats.
c) Address the following estimate comments:
i) Explain whether cut/fill includes all offsite and onsite, as well as earthwork for three new building pads, and basin areas.
ii) Revise or justify the quantities listed for the following:
(1) Handicap ramps; there are 4 listed and 6 shown on the grading plan.
iii) Revise or justify the unit costs that appear too low for the following:
(1) Aggregate base
(2) Asphaltic concrete
(3) Vertical curb
iv) Provide line items for the following:
(1) Clearing and grubbing
(2) Traffic signage
(3) Grading for the roadway
(4) Concrete wheel stops
(5) Concrete drive apron at entrance
(6) Offsite pavement
(7) Offsite curb
(8) Offsite sidewalk
(9) Excavation for new utility trenches
(10) Basin concrete outlet structures
(11) Mobilization
(12) Contingency
d) Submit a current copy of the Title Report. The title report and final plat shall match all owners of the parcels within the proposed subdivision.

For resubmittal, please submit a revised bond estimate along with the other items listed in the previous comment letter. For further clarification, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services