Plan Number: S04-089
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL- OTHER SUBDIVISION REVIEW

Plan Number - S04-089
Review Name: RESUBMITTAL- OTHER SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/13/2005 MARILYN KALTHOFF START PLANS SUBMITTED Completed
04/28/2005 DOUG WILLIAMS ENGINEERING REVIEW Denied TO: Craig Gross, CDRC
SUBJECT: San Antonio Subdivision - 4th Review
REVIEWER: Doug Williams
DATE: 27 April 2005
CDRC Case #: S04-089
T14S, R13E, Sec. 22

Resubmittals Required: Revised Final Plat, Grading, and Landscape Plans.

SUMMARY: Engineering Division has reviewed the Final Plat, Landscape Plan, Grading Plan, Drainage Report with supporting documentation, and the Subdivision Assurances package. Approvals are not recommended at this time. Please contact me to schedule a meeting for this project. Please provide a response letter with a revised Final Plat, addressing all comments provided. The following comments are offered:

FINAL PLAT:

1. At least one corner of the subdivision must be tied by course and distance to a section corner, quarter corner, or an established City or County Survey monument. The 16th corner referenced will be acceptable if there is not a set quarter or section corner, but there must be a tie to a subdivision corner (DS 2-03.6.5 A).
2. Indicate all distances between monuments used as either measured or calculated (DS 2-03.6.5 A 5).
3. Please remove all easement points, as they are unnecessary and appear to conflict with the "Found Rebar" symbol in the legend.
4. The PAAL designation is not necessary on the plat - the 36' ingress/egress, drainage, utility, and parking easement designation is sufficient.
5. Provide a bearing and distance for the leg at the southwest corner of Lot 5.
6. Check/revise the bearing provided on the southeast corner of Lot 6.
7. Check/revise spelling of the words "and" and "ingress" in the existing 15' sewer easement callout description below Lot 5.
8. The sum of the individual lot dimensions provided on the interior eastern boundary do not appear to equal the sum of the greater lengths provided on the exterior of the boundary.
9. Remove the term "Common Areas" from Dedication Note 2, mid-paragraph.
10. Revise General Note # 3 - the total miles of new private streets = 0.
11. Previous assurances review comment # 2 c discussed exclusion of survey monuments from the assurable items list. The plat however, still depicts what appear to be property corners within the Ingress/Egress easement, with no corresponding symbol in the legend. Please provide this symbol with a description in the legend, or revise as appropriate.
12. Depict, label and dimension with bearings all easements listed in the Special Report or Title Report (items 5, 7, & 8), if to remain, and include pertinent recording information on the plat. Discuss in the response letter what easements will be, or have been abandoned, and explain whether the ingress/egress easement must remain to serve other properties. Please state whether these items are shown on the plat in the response letter and provide recording information for all abandoned easements (DS Sec.2-03.6.5.B).

ASSURANCES

1. The Special Report submitted includes owners that do not appear on the plat. Please provide an updated report reflecting only the owners indicated or revise the plat to reflect signature blocks for all owners.
2. Please include the following in the subdivision title/description underlined in paragraph 1 of the Amendment to Trust: "Lots 1-6". All sections of the assurance documentation must match word-for-word for the description of the Subdivision listed on the plat

The final plat cannot be scheduled for Mayor and Council consideration until the assurances are approved by the City Engineer's Office (DS 2-03.7.1G & 2-03.9.3 E).

Resubmittal will require: Revised Final Plat, Grading, and Landscape Plans depicting revisions to the plat that may affect the plans

If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us.

Doug Williams
Sr. Engineering Associate
Engineering Division
Development Services Department
05/11/2005 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
Principal Planner

PROJECT: S04-089
San Antonio Drive, Lot 1-6
Minor Subdivision

TRANSMITTAL: 05/11/05

DUE DATE: 05/11/05

COMMENTS:

1. The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

2. Per you response to Zoning comment 3, building floor plan and elevations were submitted with the final plat package. I could not find attached to the final plat any plans requested. I have given a conditional approval of this plan with the understanding that at time of submittal of the mylar copy that the requested documents will also be included or may be brought in for zoning review prior to submittal of the mylar.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

C\planning\cdrc\finaplat\S04089fpca

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Requested documents per conditional approval.
05/12/2005 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Completed COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 12, 2005

Kent Delph
Delph Engineering
221 N. Court Ave #102
Tucson, AZ 85701

Subject: S04-089 San Antonio Drive Plat

Dear Kent:

Your submittal of April 13, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Plat and landscape plan (engineering, zoning, DSD)


ASSURANCES TO BE SUBMITTED TO THE CDRC OFFICE

Should you have any questions, please call me at 791-5608.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 882-6570
05/12/2005 PATRICIA GEHLEN ZONING-RECORDATION REVIEW Needs Review