Plan Number: S04-089
Parcel: Unknown

Review Status: Completed

Review Details: ASSURANCES

Plan Number - S04-089
Review Name: ASSURANCES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/31/2005 MARILYN KALTHOFF START ASSURANCES RECEIVED Completed
01/31/2005 MATT FLICK ENGINEERING FOR ASSIGNMENT Completed Unsigned copies forwarded to Elizabeth E. for assignment.
02/09/2005 DOUG WILLIAMS ENGINEERING REVIEW Completed Unsigned copies forwarded to Elizabeth E. for assignment.
02/09/2005 VICTOR DURAND ENGINEERING ASSURANCES RECEIVED/SENT TO CITY ATTORNEY Needs Review Unsigned copies forwarded to Elizabeth E. for assignment.
02/09/2005 VICTOR DURAND ENGINEERING ASSURANCES RECEIVED/SENT TO CITY ATTORNEY Needs Review TO: Craig Gross, CDRC
SUBJECT: San Antonio Subdivision - Minor Plat resubmittal
REVIEWER: Doug Williams
DATE: 9 February 2005
CDRC Case #: S04-089
T14S, R13E, Sec. 22

Resubmittals Required: Revised Final Plat, Grading Plans, and a revised Subdivision Assurance Package addressing the items listed below.

SUMMARY: Engineering Division has reviewed the Final Plat, Landscape Plan, Grading Plan, Drainage Report with supporting documentation, and the Subdivision Assurances package. Approvals are not recommended at this time. Please provide a response letter with a revised Final Plat, Grading, and Landscape Plans, and revised Subdivision Assurance items listed below, addressing all comments provided. The following comments are offered:

PLAT:

1. Detention/retention areas must be clearly identified as such on the plat, distinguishing them from the ingress/egress/utility/parking and drainage easement(s). Revise labeling and Dedication Note #2 to specifically include the detention/retention basins and drainage facilities as referenced in General Note 11 and omit those items not to be recorded (DS 2-03.6.1.H 1 & DS 2-03.6.4 I).
2. Remove the legend keynote identifying the "Private Street", revise General Note 3 (no new private or public street), and identify the retention/detention basins and visitor parking areas with their respective symbols, if they are to be retained in the plat legend.
3. Please explain the purpose of including the "existing lots and parcel" detail on the plat. This detail, unless necessary or requested by city staff, should be removed from the plat.
4. Revise the cover sheet to reflect pending trust agreement(s), including dedication and beneficiary paragraphs.
5. Provide a signature block and signature, with Trust Company information under the Dedications paragraph. Remove the signature blocks currently provided under this Dedication paragraph and include the names (only) under the Beneficiary paragraph.

ASSURANCES:

1. Provide clarification as to why only one "beneficiary" appears on the Amendment to Trust, and as "subdivider" on the Agreement to Construct, when there appears to be more than one parcel owner for this project. These documents must include all parties affected by this platting.
2. Address the following comments in Exhibit B of the Agreement to Construct:
a) remove the words "approved Tentative Plat" from the list assurable items 1, 2, and 8;
b) revise assurable item 7 to reference "traffic" signage, rather than "street " signage;
c) revise the term "streets" to specify the "Ingress/Egress Easement" to be recorded, and clarify whether there will be any survey monumentation. Although indicated as a monument to be set at the Ingress/Egress (PAAL) entrance on the plat, the identifying symbol describes a ½ iron rod to be set here and at various other locations (property corners) in the center of the PAAL. If an actual survey monument is not to be set, remove this item from the assurable items exhibit (item 1),
d) provide documents described as "Commitment for Title Insurance" (or Special Report) as a part of the trust agreement for verification of vested interest of all the parcels for this project.
3. The Title report submitted covers only some of the parcels within this project - please submit a complete, updated Title Report for all the parcels within this proposed subdivision.
4. Please verify curve table data C1 and C2, and provide individual distance dimensions between the survey monument and the intersections of curves (C1 & C2) with west property lines.


GRADING PLAN:

Subsequent grading plan comments may be necessary upon grading plan/permit application submittal, via standard grading plan submittal procedures and plan review processes. Listed below are salient items in need of corrections/revisions:

1. Revise keynote #3 to specify 5' sidewalk, 2' from back of curb (DS 3-01.2.7 & 3-01.3.3 A).
2. Provide the maximum water surface elevation for the south basin.
3. Provide individual lot grading information and/or detail(s) for lots 1, 2, 4 & 5.
4. Please label all existing contour elevations - only an existing elevation of 90 could be determined from the current plan.
5. Provide slope information for the north slope of the north basin.
6. Depict and label minimum 18' curb return radii at the PAAL intersecting San Antonio Dr., and at the T-turnaround onsite, in accordance with Development Standard 3-01.10, Figure 6.
7. Additional basin dimensioning and east-west outlet weir cross-sections with pertinent elevations will be necessary for the retention/detention basin.

GENERAL COMMENTS:

1. Sheet numbering does not indicate an additional Plat (?) sheet (Supplemental Zoning Data and Utility Plan). Please revise sheet numbering if this sheet is to be included as a part of this platting. See any zoning review comments related to this sheet.
2. As previously noted, a grading permit will be required for this project development prior to any earth disturbing activities. Grading shall be in conformance with all soils and geotechnical report recommendations, and Development Standard 11-01.0 - Excavation and Grading requirements, at a minimum.
3. The final plat cannot be scheduled for Mayor and Council consideration until the assurances are approved by the City Engineer's Office (DS 2-03.7.1G & 2-03.9.3 E). All sections of the assurance documentation must match word-for-word for the descriptions of the Subdivision and Common Areas listed on the plat. Please assure all document verbiage for the subdivision description matches the Final Plat.

Please resubmit a revised Final Plat, Grading Plan, and a complete, revised subdivision assurance package addressing all comments provided above.

If you have any questions, I can be reached at 791-5550, ext. 1189 or via email at: Doug.williams@tucsonaz.gov

Doug Williams
Sr. Engineering Associate
Engineering Division
Development Services Department