Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S04-086
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/22/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/02/2006 | PETER MCLAUGHLIN | ZONING | REVIEW | Approv-Cond | COMMENTS The Zoning Review Section approves the final plat for this subdivision, subject to the following changes. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 1. The CC&R's must be revised as follows: On the cover sheet please reference all the subdivision information found in the title block located on each sheet of the final plat (i.e. subdivision name, number of lots, common areas, RCP reference). If you have any questions about this transmittal, please call Pete McLaughlin (520) 791-7087 x 1178 |
| 03/06/2006 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approv-Cond | SUBJECT: ENCANTO VILLAGE Lots 1-11 S04-086 Tucson Electric Power Co. (TEP) has received the final plat submittal dated February 22, 2006 for this subdivision. TEP is unable to approve the plat at this time. Enclosed is the preliminary electrical design for the subject subdivision. Please review this design and contact this office with any conflicts or desired changes. Your written approval of this design and TEP's final plat approval are necessary for a final construction drawing. In order for TEP to approve the final plat, easements are required for the aboveground equipment. See the design for specific easement requirements. Show all requested easements on the resubmittal of the final plat. Submit two bluelines to the the City of Tucson for TEP's final approval. A copy of the preliminary design has been forwarded to Southwest Gas. Please insure utility coordination by providing a copy of this preliminary design to Qwest and the Cable Company. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |
| 03/06/2006 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approv-Cond | SUBJECT: ENCANTO VILLAGE Lots 1-11 S04-086 Tucson Electric Power Company (TEP) is in receipt of the final plat dated March 28, 2006. TEP conditionally approves this plat. This plat shows the 8' x 8' easements required for TEP's facilities. Please delete the word FOR from the second paragraph of the dedication to read as: "WE HEREBY GRANT TO THE PUBLIC AND ALL UTILITY COMPANIES ALL PUBLIC AND PRIVATE EASEMENTS AS SHOWN HEREON FOR THE PURPOSE OF ACCESS, INSTALLATION AND MAINTENANCE OF PUBLIC SEWERS AND UTILITIES AND OTHER USES AS DESIGNATED BY THIS PLAT". Please forward any resubmittals of the final plat to this office. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com |
| 03/08/2006 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | TO: Patricia Gehlen; CDRC Coordinator DATE: March 8, 2006 SUBJECT: Engineering review of the Encanto Village Final Plat. The activity number is S04-086. SUMMARY: The Final Plat, the CC&Rs and the Assurance package were received by Engineering on February 22, 2006. Engineering has reviewed the received items and does not recommend approval of the Final Plat. RESUBMITTAL REQUIRED: FINAL PLAT APPROVED: CC&Rs, BOUNDARY CLOSURE CALCS ASSURANCES APPROVABLE ONCE THE PLAT IS APPROVED The next submittal must address the following items: GENERAL COMMENTS 1. The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet. DS Sec.2-03.7.1.G The Final Plat will not be approved until the Assurance Package is received and approved. FINAL PLAT 1. Indicate on the plat whether all bearings and distances are calculated or measured. DS 2-03.6.5.C.5. It is acknowledged that symbols have been added to the legend for calculated or measured bearings and distances, however the bearings and distances have not revised on the plat (sheet 2). Revise the plat to show all bearings and distances as calculated or measured. |
| 03/13/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES March 13, 2006 Bill Baker Baker and Associates 1636 North Swan Road #200 Tucson, AZ 85712 Subject: S04-086 Encanto Village Final Plat Dear Bill: Your submittal of February 22, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 3 Copies Revised Final Plat (TEP, Engineering, DSD) Should you have any questions, please call me at 791-5608. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 318-1930 |