Plan Number: S04-083
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S04-083
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/10/2005 CRAIG GROSS COT NON-DSD REAL ESTATE Approved no comments/objections.
01/10/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
01/10/2005 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

RICK LYONS
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: December 30, 2004


RE: Assessor’s Review and Comments Regarding Final Plat
S04-083 Bach Property T131436 (110-16)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.







Susan King
12/03/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
12/10/2004 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: BACH PROPERTY
Lots 1-20
S04-083

Tucson Electric Power Company (TEP) has reviewed the final plat dated
October 20, 2004. TEP is unable to approve the plat at this time.

Enclosed is the preliminary electrical design for the subject subdivision.
Please review this design and contact this office by December 23, 2004 with
any conflicts or desired changes. Your written approval of this design is
necessary for a final construction drawing. Any changes requested after we
have proceeded with a final construction drawing will be billable.

In order for TEP to approve the final plat, the following is required:

* Show the easement recording information for the enclosed easement.
It was recorded January 7, 1982, Docket 6692 at Page 634-645.

A copy of the preliminary design has been forwarded to Southwest Gas.
Please insure utility coordination by providing a copy of this preliminary
design to Qwest and the Cable Company.



Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8745
Cell Phone: (520) 904-2668
Fax: (520) 917-8700
12/10/2004 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-083 BACH PROPERTY/FINAL PLAT
DATE: December 9, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


Change Section 36T to 36 on Location Map.

Correct North arrow on pg. 2.

Is this interior street a cul-de-sac? If so, Sahuara Place is o.k.















jg
12/20/2004 DAN CASTRO ZONING REVIEW Approv-Cond COMMENTS:

The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

1. Note the subdivision case number S04-083 in the lower right corner of each sheet of the final plat.


If you have any questions about this transmittal, please call Dan Castro at (520) 791-5608.
12/29/2004 PAUL MACHADO ENGINEERING REVIEW Denied To: Douglas Schneider, P.R.L.S.,DATE: December 29, 2004
Rick Engineering Co.
1745 E. River Road Tucson, Arizona 85718

SUBJECT: Bach Property, 2660 N. Sahuara Ave.
Final Plat S04-083 (First Review)
T13S, R14E, Section 36

RESUBMITTAL REQUIRED: Final plat Assurances.

The Final plat (FP) and Assurances cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please include a response letter to the comments along with the corrected copies with re-submittal.
2. Please submit a copy of the subdivision boundary closure sheets.
3. Separate the drainage areas/facilities from the landscape areas and identify each with consecutive corresponding common areas. The title block will have to be modified to reflect these changes, i.e.:
Common Area "A" - Streets
Common Area "B" - Drainage/Recreation Facilities
Common Area "C" - Recreation Facilities
Common Area "D" - Drainage Facilities
Common Area "E" - Landscaping
4. The SVT's on the plat are not shown correctly. The line adjacent to the longest leg of the SVT, the stem side, is 20 feet long, not 15 feet and the far side line is adjacent to the curb per D.S. 3-01.5.1.B.
5. Designate the corner lots with a star symbol for access. Place the star opposite of the curve radii for each corner lot and at the furthest corner away from the intersection on lot 14 and add to legend per D.S. 2-03.6.4.G.
6. Add the 1' no vehicular access easements for lots 1 and 20 as is shown on lot 3 per D.S. 2-03.6.4.G.
7. Reference the basis of bearings per D.S. 2-03.6.5.C.1.
8. Label all monuments found or set per D.S. 2-03.6.5.C.4.
9. Show the distance and bearings between monuments and indicate whether measured or calculated D.S. 2-03.6.5.C.5.
10. The assurance package must be updated to reflect the changes on common areas. The assurance package must match the plat description exactly.
11. Place the subdivision number (S04-083) on the FP per D.S. 2-03.6.1.K.
12. The parcel of land to the Northwest (Howard Bach) is "unsubdivided" however, by replacing the "unsubdivided" with the parcel number it may be more of an accurate description.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:\2660 N. Sahuara Ave FP
12/29/2004 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approv-Cond December 29, 2004

TO: James King
Rick Engineering Company, Inc.

THRU: Craig Gross
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Bach Property, Lots 1-20 and Common Areas A1-A4 and B1-B3
Final Plat - 1st Submittal
S04-083

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

1. A public Sewer Service Agreement for the proposed number of residential lots is being prepared, however necessary information is missing from the final plat. The owner is being listed as Raul Romero Lopez, however no address is being provided. Please provide an address so that the sewer service agreement can be completed and sent to your office. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals should be returned to Pima County Wastewater Management in order to satisfy the necessary requirements needed to approve the Mylars of the final plat.

2. SHEET 2. Recently, Pima County has decided not to require public sewer easements through common areas any longer, thus you may delete the public sewer easement within Common Area A4.

3. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project