Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S04-076
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S04-076
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/07/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/09/2004 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-076 SYCAMORE PARK VILLAGE 1 / FINAL PLAT
DATE: JULY 8, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1: Fill in all books and pages when recorded.

2: Label approved interior street names.
07/13/2004 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied Sycamore Park Villages 1-7
S04-076, S04-077, S04-078, S04-079, S04-080, S04-081, S04-082

Tucson Electric Power Company (TEP) has received the final plats for review. This Company is unable to approve the plats at this time.

In order to determine our easement requirements the electrical designs must be completed. TEP will provide a design for each of the villages upon receipt of an Approved tentative plats. At the customer's request, a design can be provided prior to the Approved Tentative Plat, however, once a design is provided, any design changes may be billable to the developer.

Additional plans necessary for preparation of the design are: building plans including water, electrical, paving and driveway placements.

Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8479
Cell Phone/Pager: (520) 904-2668
Fax: (520) 917-8400
07/21/2004 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

RICK LYONS
ASSESSOR



TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor's Office
Mapping Department

DATE: July 19, 2004


RE: Assessor's Review and Comments Regarding Final Plat
S04-076 Sycamore Park Village 1 T151532 (141-25)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.


COMMENTS: Thank you for your submittal.

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.






Susan King
07/29/2004 ANY ENGINEERING REVIEW Denied To: Craig Gross DATE: July 29, 2004
Project Manager
SUBJECT: Sycamore Park Village 1 FP
S04-076 (First Review)
T15S, R15E Section 32

RESUBMITTAL REQUIRED: Final plat.

The Final plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please include a response letter to the comments along with the corrected copies with the re-submittal.
2. Please submit boundary closure calculations.
3. Please submit assurances.
4. The streets must be named prior to the recording of the plat. For more information see Kay Marks at Pima County addressing.
5. Please re-label all common areas that may be used in a dual capacity. For example, a Ret./Det. Basin may also be used as a recreation facility and this must be reflected on the Final Plat. The title block shall also call out the common area designations. A key note explaining the labels as well as in the title block, ie.:
Common Area "A" - Streets
Common Area "B" - Drainage/Recreation Facilities
Common Area "C" - Recreation Facilities
Common Area "D" - Drainage Facilities
Common Area "E" - Landscaping
6. Please complete the title block per D.S. 2-03.6.1.H.
7. Please show erosion hazard setbacks and the 100-year floodplain in a surveyable manner per D.S. 2-03.6.4.E and F.
8. Please add a North arrow and scale to sheet 4 of 4.
9. Indicate access through future phases if applicable per D.S. 2-03.6.4.K.
If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax, C:/ Sycamore Park Village 1 FP
08/02/2004 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approv-Cond August 02, 2004

TO: Warren Thompson, P.E., Stantec Consulting Inc.

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: Sycamore Park - Village 1, Lots 1-94 and Common Area A
- Submittal
S04-076


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


ALL SHEETS. Add the project number, S04-076, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

We have sent to your office under separate cover a Sewer Service Agreement for the proposed number of residential lots. Once the three originals of the Agreement have been signed by the Owner of Record, and notarized, they must be returned to Wastewater Management in order to satisfy the necessary requirements needed to approve the final plat.

This office cannot approve this final plat at this time, but a resubmittal of bluelines is not necessary. This office will approve this submittal of the final plat subject to the required revision(s) shown above, when we receive the three signed and notarized orginals of the Sewer Service Agreement.



If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.

Copy: Project
08/02/2004 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approv-Cond Waiting for sewer agreements to be signed.
08/04/2004 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
08/04/2004 DOROTHY ROBLES COT NON-DSD REAL ESTATE Approved no objections
08/04/2004 DAN CASTRO ZONING REVIEW Denied COMMENTS
CODE SECTION/ DEVELOPMENT STANDARD

1. An applicant has one (1) year from the date of approval of the tentative plat to obtain approval and recordation of a final plat that complies with zoning and other development requirements in effect at the time of application. Since the tentative plat for this subdivision has not yet been approved, the approval date for this final plat may not be determined. In addition, the final plat may not be approved prior to approval of the tentative plat. Since the tentative plat has not yet been approved, any revisions made to the tentative plat which effect the final plat must also be made to the final plat.
L.U.C. 4.1.7.3

2. This final plat has been assigned subdivision case number S04-076. Please note the subdivision case number in the lower right corner of each sheet. The case number shall be larger or bolder than the reference case numbers already listed.
D.S. 2-03.6.1.K

3. Please clarify whether Sycamore Park Boulevard has been recorded by the block plat. If so, note the recordation information on the plat. If it hasn't, recordation information must be listed prior to final plat approval.


4. CC&R's have not been approved. Refer to tentative plat Zoning review comments dated June 23, 2004 for requirements. Final plat may not be approved until the CC&R's have been reviewed and approved.
D.S. 2-03.6.6/ D.S. 2-10.3.2.E/ L.U.C. 3.6.1.5


If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.