Plan Number: S04-075
Parcel: Unknown

Address:
11 W DREXEL RD

Review Status: Completed

Review Details: RESUBMITTAL- OTHER SUBDIVISION REVIEW

Plan Number - S04-075
Review Name: RESUBMITTAL- OTHER SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/28/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/01/2004 JOE LINVILLE LANDSCAPE REVIEW Approved
11/03/2004 FRODRIG2 PIMA COUNTY WASTEWATER Approved November 01, 2004

TO: René Piña, P.E.

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: 6th & Drexel Subdivision
- Submittal
S04-075


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.



If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.

Copy: Project
11/14/2004 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT: S04-075
6th and Drexel Subdivision, Lots 1-6 and Common Area "A"
Final Plat

TRANSMITTAL: November 14, 2004

DUE DATE: November 12, 2004

COMMENTS:

1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before July 9, 2005.

2. Remove the word setback from the MS&R R.of W. label. The note should state 65' Half R.O.W. and 75' Half R.O.W.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.DGR C:\planning\cdrc\finalplat\S04075fp2.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat and CC&R's and additional requested documents
11/15/2004 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
11/15/2004 DOUG WILLIAMS ENGINEERING REVIEW Denied TO: Craig Gross, CDRC
SUBJECT: 6th & Drexel -Final Plat Review
REVIEWER: Doug Williams
DATE: 15 November 2004
CDRC Case #: S04-075
T15S, R13E, Sec. 12

Resubmittals Required: Revised Final Plat, Landscape Plan and one complete subdivision assurance package (including a copy of sample CC&R's, a current Title Report, sample warranty deed, Trust agreement, amendment to Trust, and all associated exhibits, at a minimum).

SUMMARY: Engineering Division has reviewed the revised Final Plat, Subdivision Assurances package, Concept Grading Plan, boundary survey calculations and Drainage Report. A revised Landscape Plan was not included in the resubmittal. Approvals are not recommended at this time. Resubmittal shall include a revised Final Plat, a copy of the approved Landscape Plan, and a complete subdivision assurance package addressing the comments below. The following comments are offered:

FINAL PLAT:

1. Check the basis of bearings provided for the project. It appears the bearing referenced does not correspond with Drexel Road, as stated in General Note 4.
2. Remove the term "setback " from Drexel Rd. and Sixth Ave. right of way labeling.
3. Please revise the language in paragraph 4 under "DEDICATION" to read as discussed, and as provided in Development Standard 2-03.6.3 B 3.
4. Assure all signatures are provided as required in the Certification of Survey and Dedications paragraphs, accompanied by notary seal and signature upon submittal of Mylars (DS 2-03.6.3 A & B).
5. A state-registered Civil Engineer's seal and signature will be necessary on the plat, due to state platting requirements for floodplain elevation and delineation certification(s) (DS 2-03.2.2 A 2).

CONCEPT GRADING PLAN:

The concept grading plan is not required to be included with a resubmittal. Revisions to the plan will be necessary however. The following comments must be addressed on the plan prior to submittal for a grading permit application.

1. Provide a current, working "Bluestake" telephone number.
2. Depict and label all new sidewalks to be 6' wide in Drexel Rd. and Sixth Ave. rights of way, in accordance with Mayor and Council Policy guidelines for new sidewalks on all Major Streets and Routes.
3. The grading plan should include cross sections depicting existing and proposed grades for each perimeter. Please note that the section provided does not include a 2' grading setback from the top of cut for the detention basin, as previously requested.

GENERAL COMMENTS:

1. Arizona Pollutant Discharge Elimination System (AZPDES) requirements are applicable to this project. Stormwater Pollution Prevention Plans and text addressing stormwater controls for all areas affected by construction activities related to this development will be required with a grading plan/permit submittal. For further information, visit: http://www.adeq.state.az.us/environ/water/permits/stormwater.html
2. The final plat cannot be scheduled for Mayor and Council consideration until the assurances are approved by the City Engineer's Office (DS 2-03.7.1G & 2-03.9.3 E). All sections of the assurance documentation must match word-for-word for the descriptions of the common areas listed on the Final Plat. Please assure all document verbiage for the subdivision description matches the Final Plat. For example, the letter and use for each common area description shall match the Plat Title Block descriptions and letters. This must be correct in order to prevent delay of the assurance review in the City of Tucson's legal offices.
Resubmittal will require:

A revised Final Plat, a copy of the approved Landscape Plan, a complete subdivision assurance package (including a copy of sample CC&R's, a current Title Report, sample warranty deed, Trust agreement, amendment to Trust, and all associated exhibits at a minimum), addressing all comments provided above.

If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us.

Doug Williams
Sr. Engineering Associate
Engineering Division
Development Services Department
11/15/2004 CRAIG GROSS ZONING-RECORDATION REVIEW Passed