Plan Review Detail
Review Status: Completed
Review Details: FINAL PLAT REVIEW
Plan Number - S04-070
Review Name: FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/05/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/18/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S04-070 CORONA ROAD ESTATES / FINAL PLAT DATE: JULY 15, 2005 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1: Change the eastern most 4-40 to 58-43 on Location Map. 2: Change Tucson-Nogales Hwy to Nogales Hy. On Location Map. 3: Add Avenue to 6th on Location Map. 4: Change 13-26 to 31-26 on Location Map. 5: Spell out Avenue of San Fernando Ave. on pgs 2 & 3. 6: Change Corona Street to Road. 7: Spell out Avenue of 12th Ave. on pgs. 2 & 3. |
| 07/29/2005 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | No objection |
| 07/29/2005 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | July 29, 2005 TO: Greg Carlson, P.E. Greg Carlson Engineering, LLC THRU: Patricia Gehlen City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Corona Road Estates, Lots 1-20 and Common Areas A & B Final Plat – 1st Submittal S04-070 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. A public Sewer Service Agreement for the proposed number of residential lots has been prepared, however the trust number information is missing. As soon as this information is provided, the Sewer Service Agreement will be sent. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals should be returned to Pima County Wastewater Management in order to satisfy the necessary requirements needed to approve the project. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 08/04/2005 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: CORONA ROAD ESTATES Lots 1-20 S04-070 Tucson Electric Power Company (TEP) has received the final plat submitted for review July 5, 2005. This Company is unable to approve the plat at this time. TEP is in the process of completing the preliminary electrical design to determine our easement requirements. When the design is completed we will send it out along with the easement requirements necessary for Final Plat approval. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 08/05/2005 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | TO: Patricia Gehlen; CDRC Coordinator SUBJECT: Corona Road Estates Final Plat Engineering Review LOCATION: T15S R13E Section 13 REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: S04-070 SUMMARY: The Final Plat and CC&R's were received by Engineering on July 5, 2005. Engineering Division does not recommend approval of the Final Plat at this time. FINAL PLAT COMMENTS: 1) City of Tucson Development Standards (DS) Section No.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. Submit the following for other portions of the assurance package: a) If a third party trust is proposed for the subdivision assurances, provide: i) original copy of the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST; ii) original copy of the AMENDMENT TO TRUST / THIRD PARTY TRUST; iii) assure that all exhibits are attached, and the case number "S04-070" is at the top of the first page of the AGREEMENT TO CONSTRUCT and AMENDMENT TO TRUST; iv) copy of the original Trust Agreement; v) copy of a sample Warranty Deed; vi) copy of the Title Report. b) DS Sec.2-03.6.5.B: Assure that any/all easements listed in the title report are clearly drawn, labeled with Book/page or Docket/page, and/or listed as a blanket easement, and/or labeled with accurate dimensions and bearings on the plat. In response letter, explain whether any easement items in the title report are not shown on the plat. c) Before submitting the assurance paperwork, assure that the descriptions of the common areas of the Final Plat title block match the assurance paperwork descriptions of the subdivision common areas. Please be aware that the legal office may reject the assurance paperwork if the verbiage does not match exactly the verbiage on the Final Plat's Title Block. d) For this and future projects, please provide a 8½" by 11" location map sheet for assurance submittals that go to Mayor & Council. Typically, these are similar to an enlarged location map on Final Plats. 2) DS Sec.10-02.14.3.2: Provide a signed copy of the CC&R's. 3) DS Sec.2-03: Address the following comments for sheet 1: a) DS Sec.2-03.6.3.D: For the signature lines under the "Assurances" paragraph, replace the signature line title "City of Tucson Engineer" with "City of Tucson Development Services Department Engineering Administrator" 4) DS Sec.2-03: Address the following comments for sheet 2: a) DS Sec.2-03.6.4.G: For lots 1 and 20, provide star symbols to indicate driveway access location. b) DS Sec.2-03.6.4.H: Provide 1-foot no vehicular access easements along the north sides of lots 1 and 20. c) DS Sec.2-03.6.5.B: Indicate/clarify whether the bearing for Missiondale Road is N00°14'56"W. 5) DS Sec.2-03.6.5.C.3: Provide a boundary closure calculation sheet for the project. For resubmittal, please submit a response letter, the assurance package items, signed copy of the CC&R's, and the revised Final Plat. For further clarification, call me at 791-5550, extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 08/10/2005 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Ed Abrigo, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: August 3, 2005 RE: Assessor’s Review and Comments Regarding Final Plat S04-070 Corona Road Estates T151313 (138-21) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Jessica Shettleroe |
| 08/11/2005 | TERRY STEVENS | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: S04-070 Corona Road Estates Final Plat TRANSMITTAL: 08/11/05 DUE DATE: 08/02/05 COMMENTS: 1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before 06/06/2006. 2. The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 3. On the first page of the Declaration of Covenants, Conditions and Restrictions include in the title portion the following, "Lots 1 -20 and Common Areas "A" and "B" and the legal description as indicated in the title block of the final plat. If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000. C\planning\cdrc\finaplat\S04-070fpca RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, tentative plat, final plat, CC&R's and additional requested documents. |
| 08/13/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 11, 2005 Greg Carlson, P.E. Greg Carlson Engineering, LLC 1521 East Broadway Blvd. Tucson, AZ 85719 Subject: S04-070 Corona Road Estates Final Plat Dear Greg: Your submittal of July 5, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 5 Copies Revised Final Plat (Addressing, TEP, Engineering, Zoning, DSD) 3 Copies Revised CC&R's (Engineering, Zoning, DSD) ASSURANCES TO BE SUBMITTED TO THE CDRC OFFICE Should you have any questions, please call me at 791-5608. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 624-4197 |