Plan Number: S04-070
Parcel: Unknown

Address:
225 W CORONA RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S04-070
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/17/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/22/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-070 CORONA ROAD ESTATES/REVISED TENTATIVE PLAT
DATE: 3/22/05



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Change Tucson-Nogales Hwy to Nogales Hy on Location Map.

Change 13-26 to 31-26 and 4-40 to 58-43 on Location Map.

Spell out all street suffixes except on Location Map.
04/02/2005 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: S04-070
Corona Road Estates, Lots 1 - 20 and Common Areas "A" and "B"
Tentative Plat

TRANSMITTAL: 04/02/05

DUE DATE: March 31, 2005

COMMENTS:

1. The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

2. Add to general 3 on sheet one for the subject to section, ". H " after the Subject to section number 3.5.7.1.E, .F, .G.

3. For consistency with the Land Use Code requirements, keynote four under building setbacks on sheet 2, must be revised to state the correct building setback for the interior street building setbacks. The correct setback is based on the greatest of 21 feet or the height of the structure from the nearest edge of travel lane.

It is acknowledged that a 6-foot wide easement is proposed behind the property line and that no structure may be constructed over the easement other than a walkway or the driveway.

The setback for the garage or carport setback has been listed correctly.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

C:\planning\cdrc\tentativeplat\S03070tpca.doc
04/07/2005 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond Additional note required on the landscape plan to clarify that landscaping will be installed in the common areas. Plans depict plants outside of common areas in conflict with COT requirements and note 13 on the landscape plan.
04/08/2005 DALE KELCH COT NON-DSD TRAFFIC Denied >>> Dale Kelch 4/6/2005 3:41:49 PM >>>
Traffic Engineering REJECTS this TP:

1. The symbol used for new street signs is not correct in accordance with Standard Details for Public Improvements, SD100, 2003 edition.

2. Rotate the symbol at the eastern PRC 180 degrees.

3. Modify the note concerning no parking sign installation. These signs shall be installed by the Developer/Owner. City forces ARE NOT responsible for sign installation.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
04/22/2005 ELIZABETH EBERBACH ENGINEERING REVIEW Denied TO: Craig Gross; CDRC Coordinator
SUBJECT: Corona Road Estates 2nd Submittal Tentative Plat Engineering Review
LOCATION: T15S R13E Section 13
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: S04-070

SUMMARY: The revised Tentative Plat, landscape documents, revised Drainage Report, Geotechnical Report and title report paperwork were received by Engineering on March 17, 2005. Engineering has reviewed the received items and does not recommend approval of the Tentative Plat or the Drainage Report at this time. The Drainage Report was reviewed for Tentative Plat purposes only.

DRAINAGE REPORT COMMENTS:
1) City of Tucson Development Standards (DS) Section No.10-02.2.3.1.4.C.8: Provide copy of drainage report which states that the new El Vado Wash channel is designed to fully contain the 100-year flows. Response letter states that a copy of the report would be attached in this submittal, however Appendix D is missing.
2) DS Sec.2-03.2.4.L.5: The proposed basin outlets to the south by a weir and by bleeder pipe. Correspondence will be required when any drainage solution occurring outside the boundaries of the plat is constructed with adjacent owners' permission. (Additional documentation may be needed of that approval (from TDOT) and submitted with the drainage report.)
3) DS Sec.10-02 page 8.06: Table 8.1: Revise worksheets for scuppers and roadway capacities to reflect a roadway Manning's coefficient of .020 for the maximum value for asphalt when cars are present, per this section of the standards. Revise Tentative Plat accordingly.

TENTATIVE PLAT COMMENTS:
4) DS Sec.10-02 page 8.06: Table 8.1: Revise Tentative Plat according to revised worksheets for scuppers and roadway capacities with a roadway Manning's coefficient of .020.
5) DS Sec.2-03.2.4.F: For detail A on sheet 3/3, street section shall reflect geotechnical recommendations or 2.5" AC over 4" base course, per the Pattison-Evanoff report page 11.

LANDSCAPE PLAN COMMENTS:
6) DS Sec.10-02.14.3.4: Delineate basin access and show that no proposed vegetation will block access.

The next submittal should address all the above items. Submit copy of the response letter, the revised Tentative Plat, revised Drainage Report and revised Landscape Plan. You may call to schedule an appointment to go over these comments, or if you have any questions, please call me at 791-5550 extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
04/27/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed