Plan Number: S04-065
Parcel: Unknown

Address:
2021 W 36TH ST

Review Status: Completed

Review Details: ASSURANCES

Plan Number - S04-065
Review Name: ASSURANCES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/04/2004 MARILYN KALTHOFF START ASSURANCES RECEIVED Completed
11/04/2004 MATT FLICK ENGINEERING FOR ASSIGNMENT Completed A copy of the Agreement ot Construct and the Amendment to Trust have been received to Elizabath Eberbach.
12/02/2004 SUE MONTES CDRC STAFF ASSURANCES RECEIVED Needs Review need to address 2DEC04 assurance comments.
Assurances acceptable 8DEC04 & assurance transmittal paperwork complete.
12/02/2004 ELIZABETH EBERBACH ENGINEERING REVIEW Denied DATE: December 2, 2004
TO: Craig Gross; CDRC Coordinator
SUBJECT: San Marcos Terrace Final Plat Submittal Engineering Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: S03-004

SUMMARY: The Final Plat, CC&R's, and assurance package were received by Engineering on October 20, 2004. Development Services Department Engineering Division has done a review of the received items and does not recommend approval at this time. These comments may be addressed on a mylar submittal, with CDRC's permission.

FINAL PLAT COMMENTS:
1) City of Tucson Development Standards (DS) Section No.2-03.8.1.A: Provide seals and signatures of Engineer and Surveyor on mylar submittal for approval.
2) DS Sec.2-03.7.1.B: If engineering information is provided on the final plat, the seal and signature of the responsible engineer is also required. For the Certification of Engineering, add that the basin setback information also has been prepared by the engineer of record, or clarify verbiage for the engineering information.
3) DS Sec.2-03.6.4.E: Show the required basin setback offset from the 100-year ponding limits within the lots adjacent to the basins.
4) DS Sec.2-03.6.4.G&H: For the south and east boundary, designate a 1 foot no-vehicular access easement.
5) DS Sec.2-03.6.5.C.3: Provide the boundary closure calculation sheet.
6) DS Sec.2-03.7.1.B: Provide a copy of the signed original CC&R's.
7) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. Address the following comments for the assurance package:
a) Add activity number "S04-065" to the exhibits.
a) Provide Exhibit "A" (property description) for the AMENDMENT TO TRUST / THIRD PARTY TRUST.
b) Provide Exhibit "A" (property description) for the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST.
c) Provide Exhibit "B" (the assurable item list) for the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST.
d) The description of the basin should reflect function of the basin as a "detention / retention basin"; revise the
i) title block,
ii) cover of CC&R's,
iii) cover page of the AGREEMENT TO CONSTRUCT, and
iv) cover page of the AMENDMENT TO TRUST.
e) Assure that the descriptions of the common areas of the Final Plat title block match the CC&R's descriptions of the subdivision common areas and the descriptions in the assurance paperwork. Please be aware that the legal office may reject the assurance paperwork if the verbiage does not match exactly the verbiage on the Final Plat's Title Block.
f) Add "Exhibit "C"" to the top of the first page of the Trust Agreement.
b) There may be opportunity to make a December Mayor and Council date if all items are addressed and other divisions approve; otherwise the "2004" dates on the first sheet would need to be updated.
8) DS Sec.10-02.2.3.1.1.B: A copy of the final draft of the Drainage Report will be needed. Make sure that the administrative address and subdivision case number is added to the cover.

For resubmittal, provide a revised Final Plat, an copy of the original signed CC&R's, boundary closure calculation sheet, copy of current title report, revised assurance exhibits, any other revised assurance documents, and a copy of the Drainage Report. The next submittal should address all the above items. If you have questions or would like to set up a meeting, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
12/02/2004 ELIZABETH EBERBACH CDRC STAFF CITY ATTORNEY'S OFFICE Denied need to address 2DEC04 assurance comments.
Assurances acceptable 8DEC04 & assurance transmittal paperwork complete.
12/13/2004 ELIZABETH EBERBACH ENGINEERING review revisions Approved
12/13/2004 ELIZABETH EBERBACH CDRC STAFF prep assurance paperwk Approved need to address 2DEC04 assurance comments.
Assurances acceptable 8DEC04 & assurance transmittal paperwork complete.