Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S04-064
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/17/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 05/18/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | 1) Sheets 3 & 4 of TP indicate improvements (retaining wall at north side of Lot 23) in scenic route buffer area. Improvements are limited to those listed in LUC 3.7.5.2.c. Revise the plans as necessary to include only permitted improvements. Items such as the retaining wall are not allowed improvements. If applicable, submit any documents referred to in the response letter that permit the improvements. No attachments were received. 2) PER LUC 3.7.5.2.E "Exposed cut or fill slopes shall be no greater than a one (1) foot rise or fall over a three (3) foot length". Revise all plans to comply with this SCZ requirement. The use of retaining walls along the scenic route is limited by the above section. If applicable, submit any documents referred to in the response letter that permit the improvements. No attachments were received. |
| 05/20/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S04-064 Sierra Pantano 05/18/05 (x) Tentative Plat () Development Plan (x) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: C9-03-17 NEIGHBORHOOD PLAN: Rincon Southeast Subregional Plan GATEWAY/SCENIC ROUTE: Scenic Corridor COMMENTS DUE BY: May 18, 2005 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached (x) No Additional Comments - Complies With Planning Comments Submitted on: 02/24/05 ( ) Resubmittal Required: ( ) Tentative Plat () Development Plan ( ) Landscape Plan ( ) Other: REVIEWER: E. Anderson 791-4505 DATE: 05/18/05 |
| 05/23/2005 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed | |
| 05/23/2005 | DAN CASTRO | ZONING | REVIEW | Approved |