Plan Number: S04-061
Parcel: Unknown

Address:
310 E MOHAVE RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S04-061
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/07/2007 MARILYN KALTHOFF START PLANS SUBMITTED Completed
02/21/2007 PATRICIA GILBERT ENGINEERING REVIEW Approv-Cond TO: Patricia Gehlen; CDRC Coordinator DATE: February 21, 2007

SUBJECT: Engineering review of the Mohave Duplex Final Plat. The activity number is S04-061.

SUMMARY: The Final Plat and Declaration of Covenants were received by Engineering on February 7th, 2007. Engineering has reviewed the received items and recommends conditional approval of the Final Plat and Declaration of Covenants.

FINAL PLAT and CC&R's are CONDITIONALLY APPROVED

SUBMITTAL: FINAL PLAT MYLAR, ORGINAL ASSURANCE PACKET, ORIGINAL SIGNED AND NOTARIZED DECLARATION OF COVENANTS

This office wanted to express acknowledgement that this project has been through several reviews and recommends meeting with the reviewer to discuss the following comments that must be provided on the final plat mylar.

The next submittal must address the following items:

GENERAL COMMENTS

1. The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet. DS 2-03.7.1.G

DECLARATION OF COVENANTS COMMENTS

1. Any reference to "Common Area" should be referred as "Common Easement." Common area is not used for this development therefore any reference should be revised to indicate easement.

FINAL PLAT COMMENTS

1. Remove the 10' setback line and notation from the plat. This is tentative plat information that is not required on the final plat.

2. Identify the dashed line (located north of the parcel) that is off set (approximately five feet) from the monument line to the south.

The above comment is from the previous review. The response to the comment was, "This is a found monument- now clarified." However when the submitted final plat was compared to the previous submittal, there is no clarification or identification on the line that was requested. A found brass cap survey monument at Fontana Ave was called out rather then the requested information. Please call out the dashed line that is off set 5' from the monument line located in Mohave Road.

In addition to the above comment the dimension, 119.96', shown adjacent to the found brass cap survey monument at Fontana Ave, appears to be the dimension and bearing for the south property line. If the dimension is the distance to the BCSM, there would be a distance the bearing to off set the BCSM from the south property line. If this assumption is correct locate the dimension and bearing call out to be beneath the south property line. Revise the plat appropriately.
02/22/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

February 22, 2007

Rene A. G. Pina, P.E.
2030 East Broadwy Blvd., Suite 28
Tucson, Arizona 85719

Subject: S04-061 Mohave Duplex Group Final Plat

Dear Rene:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents:

(2) Title reports current within the last thirty (30) days.
(1) Executed Final Plat Double Matte Océ or Photo Mylar.
(1) * Check in the amount of $8.50 per plat page for Mayor & Council distribution made payable to the local print company of your choice or provide an account number to charge.
(1) * Check in the amount of $55.00 per plat page for recorded plat distribution made payable to the local print company of your choice or provide an account number to charge.
(1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page.
(1) Executed and notarized CC&R's document (if applicable).

*Please do not combine the checks for the printing charges. They are processed at different times and require separate checks. An account number is also acceptable and you can include this information on your transmittal sheet when submitting the above listed items.

Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 7 - 8 weeks from the date submitted to the date scheduled for Mayor and Council approval.

Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 514-6893